• 제목/요약/키워드: Unit level

검색결과 3,463건 처리시간 0.031초

고부가가치선의 Unit Cabin Mock-up 을 이용한 캐빈소음 저감 연구 (Cabin Noise Reduction using Unit Cabin Mock-up of High Value Ship)

  • 주원호;송근복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.483-484
    • /
    • 2010
  • Unit cabin means room, which is installed in the high value ship such as drill ship and FPSO, after pre-assembled. In order to develop the noise control design for a unit cabin, a variety of acoustic tests such as sound absorption, transmission, and radiated noise measurements were carried out by using the mock-up of living quarter. From the tests, it was found out that the combined noise level of a unit cabin could be dominated by the radiated noise from wall panel in low frequency range and the design guidelines for the noise control of unit cabin were fully established, such as the improvement of sound transmission loss between the cabin and corridor, and radiated cabin noise reduction.

  • PDF

한글 음소 단위 딥러닝 모형을 이용한 감성분석 (Sentiment Analysis Using Deep Learning Model based on Phoneme-level Korean)

  • 이재준;권순범;안성만
    • 한국IT서비스학회지
    • /
    • 제17권1호
    • /
    • pp.79-89
    • /
    • 2018
  • Sentiment analysis is a technique of text mining that extracts feelings of the person who wrote the sentence like movie review. The preliminary researches of sentiment analysis identify sentiments by using the dictionary which contains negative and positive words collected in advance. As researches on deep learning are actively carried out, sentiment analysis using deep learning model with morpheme or word unit has been done. However, this model has disadvantages in that the word dictionary varies according to the domain and the number of morphemes or words gets relatively larger than that of phonemes. Therefore, the size of the dictionary becomes large and the complexity of the model increases accordingly. We construct a sentiment analysis model using recurrent neural network by dividing input data into phoneme-level which is smaller than morpheme-level. To verify the performance, we use 30,000 movie reviews from the Korean biggest portal, Naver. Morpheme-level sentiment analysis model is also implemented and compared. As a result, the phoneme-level sentiment analysis model is superior to that of the morpheme-level, and in particular, the phoneme-level model using LSTM performs better than that of using GRU model. It is expected that Korean text processing based on a phoneme-level model can be applied to various text mining and language models.

레이저레이더 센서를 이용한 철도 건널목 지장물 검지 알고리즘 개발 (Algorithm Development of Level Crossing Obstacle Detection using Laser Radar Sensor)

  • 김영준;백종현;최규형
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1813-1819
    • /
    • 2013
  • Existing level crossing obstacle detecting system was installed using a laser beam. Level crossing obstacle detecting system using a laser beam that has been a problem in relation to safety and maintainability failure according to weather conditions. We proposed laser radar level crossing obstacle detecting system as a way to overcome problem, and we developed an algorithm for this. Level crossing obstacle detecting system using a laser radar sensor algorithm is robust to external environment and a shadow zone does not exist. Sensor part of the laser radar level crossing obstacle detecting system of these is made up by the image processing unit and laser radar sensor, it operations by receiving train entering information from the control unit. In this paper, we proposed a detecting algorithm with calculation of the size of the laser radar sensor. Based on this, we were performance test on the basis of the scenario by making a prototype. In the future, laser radar level crossing obstacle detecting system to ensure the safety and reliability through the field test.

초지기 가압-헤드박스 내 지료유체의 공정-동특성모델 (Process -dynamic Model for Stock-fluid in a Pressurized Paper Machine Headbox)

  • 윤성훈
    • 펄프종이기술
    • /
    • 제31권3호
    • /
    • pp.35-46
    • /
    • 1999
  • Mathematical modeling provided a systematic analysis for the dynamic behavior of stock fluid in a paper machine pressurized headbox. Dynamic responses of liquid level, sheet basis weight and hydraulic pressure were predicted from the simulation model which represents the system. A unit step and asinusoidal wave load were considered as the input forcing functions in the headbox. Results are summarized as follows : 1. The dependence of sheet basis weight on liquid level in the pressurized-headbox was non -linear. 2. Liquid level in the head-box showed first-order lag with a unit step forcing to fluid input rate ; 3 . The amplitude of wave response of liquid level was inversely proportional to the time content for the sinusoidal input changes ; 4.Sheet basis weight showed second-order oscillating underamped responses for the step input load of flow rate ; 5. The damping factor in the second-order system was a function of air-pressure in the headbox ; and, 6. Dead-time existed in the measuring process for the headbox slice pressure.

  • PDF

Determination of Optimum Pressurizer Level for Kori Unit 1

  • Song, Dong-Soo;Lee, Chang-Sup;Lee, Jae-Yong;Kim, Yo-Han;Lee, Dong-Hyuk
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.437-442
    • /
    • 1997
  • To determine the optimum pressurizer water level during normal operation for Kori unit 1, performance and safety analysis are peformed. The methodology is developed by evaluating "decrease in secondary heat removal" events such as Loss of Normal Feedwater accident. To demonstrate optimum pressurizer level setpoint, RETRAN-03 code is used for performance analysis. Analysis results of RETRAN following reactor trip are compared with the actual plant data to justify RETRAN code modelling, The results of performance and safety analyses show that the newly established level setpoints not only improve the performance of pressurizer during transient including reactor trip but also meet the design bases of the pressurizer volume and pressure. pressure.

  • PDF

Affection of Blood Calcium, Ino-Phosphorus and Alkaline Phosphatase Activity Inject with Paraquat on Rats

  • Lee, Wha-Jae
    • 대한의생명과학회지
    • /
    • 제8권2호
    • /
    • pp.71-75
    • /
    • 2002
  • Paraquat (N,N'-dimethyl-4,4'-bipyrrimidinium-dichlorides (PQ): MW 186.6) has been used to killing verierty of hubside plants. For this study were use Sprague-dawely rats (190$\pm$10 gm) and injection 40 mg/kg BW of paraquat (LD$_{50}$) to 24 hrs PQ and 4 days PQ group excepte normal control. For the measurement of blood calcium Ino-phosphorus and activity of alkaline phosphatase (ALP) by HITTACH 746. In serum phosphoruse of normal control were 8.0$\pm$1.2 mg/dl and 24 hrs PQ group were 8.9$\pm$1.0 mg/dl (P<0.05) and 4 days PQ group were 8.8$\pm$0.42 gmm/dl (P<0.05). In serum phosphorus were very sensitive uptaked to 10% within only 24 hours, but 4 days of PQ were similar uptake level than 24 hrs PQ. So this 8.9 mg/dl of sem phosphorus may be thought threshold level becouse does not more encrease. In blood calcium normal of rats were measured 9.51$\pm$0.3 mg/dl and 24 hrs of PQ group were 9.9$\pm$0.51 mg/dl (uptaked 4.5%, p>0.05). This uptake cannot fined meaning mathmatic statistics but 4 days PQ groups of calcium were 10.43$\pm$0.37 gm/dl (uptaked 10%, p<0.05). That 24 hrs PQ groups of caclium dose not reacted sensitive to irritated by PQ. So, when use oxidants of PQ, the blood calcium and Ino-phosphorus were linear correlated uptake that reasone thought may be move out form hardness bone tissue to in blood it does not take feeding to hunger for 4 days. In ALP normal of rats were measured 991$\pm$106 unit/L. In 24 hrs irritated PQ rats were fall down by 629$\pm$91 unit/L (P<0.001) but in 4 days of PQ rats were 792$\pm$85 unit/L (P<0.0011) that the activity of level were mild recovered activity from 629 unit (63%) to 792 unit (80%). So, that the reasone of ALP were very sensitive activity and reverse correlated to blood calcium or phosphorus irritated by PQ.

  • PDF

Evaluating LIMU System Quality with Interval Evidence and Input Uncertainty

  • Xiangyi Zhou;Zhijie Zhou;Xiaoxia Han;Zhichao Ming;Yanshan Bian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권11호
    • /
    • pp.2945-2965
    • /
    • 2023
  • The laser inertial measurement unit is a precision device widely used in rocket navigation system and other equipment, and its quality is directly related to navigation accuracy. In the quality evaluation of laser inertial measurement unit, there is inevitably uncertainty in the index input information. First, the input numerical information is in interval form. Second, the index input grade and the quality evaluation result grade are given according to different national standards. So, it is a key step to transform the interval information input by the index into the data form consistent with the evaluation result grade. In the case of uncertain input, this paper puts forward a method based on probability distribution to solve the problem of asymmetry between the reference grade given by the index and the evaluation result grade when evaluating the quality of laser inertial measurement unit. By mapping the numerical relationship between the designated reference level and the evaluation reference level of the index information under different distributions, the index evidence symmetrical with the evaluation reference level is given. After the uncertain input information is transformed into evidence of interval degree distribution by this method, the information fusion of interval degree distribution evidence is carried out by interval evidential reasoning algorithm, and the evaluation result is obtained by projection covariance matrix adaptive evolution strategy optimization. Taking a five-meter redundant laser inertial measurement unit as an example, the applicability and effectiveness of this method are verified.

산욕부 안위에 영향을 미치는 병원환경 요인에 관한 연구 (Study on Hospital Environmental Causes Affected the Mother′s Comfort After Her Child Birth)

  • 변수자
    • 대한간호학회지
    • /
    • 제8권1호
    • /
    • pp.1-15
    • /
    • 1978
  • The Purpose of this study is to examine closely the causes influenced upon the comfort and recovery of the woman delivered of a child in the hospital at the same time to understand environmental status of hospitals in order to promote mother's health recovery, and to improve hospital environment by emphasizing the meaning of environment and health before the medical staff and hospital administrative authority. In the method of servery of the research, 165 post paestum patients have been randomly selected who were accommodated and delivered their babies at OB(obstetric ) & GY (Gynecologic) unit the 7 general hospitals for the period of 6 December 1976 through 17 December 1976. As for the survey, it has been used of Questionnaire where we have 65 items in the respect of personal environment in the hospital such as trusting nurse, ability, reliability, kindness and etiquette of nurse and tile character of nurse the relationship with patients the other respect of physical environment included 9f temperature, moisture. air-ventilation lightening noise, cleanness. facilities, and the third realm being of mother's hearth ground to have the following conclusion 1. The feature of the collected personnel they are from OB or GY sects of from OB unit of the other 5 hospitals except the two general hospitals of the college or school Otherwise the rate of the patients to nurses would be 9 : 1. As for the nurses'ground it would be appeared of 20-25 years of age as the 76%. either 3 year course or 4 year course in the education would be each 50% and less than 2 year experience case would record as of 60 %. In the respect of hospital physical environmental status, there we have two hospitals without any thermometers, on the other han4 nowhere there's hygrometer, otherwise, the lightening is normal or over than normal As for the structure of noise protection the corridors're, generally speaking worse than rooms, nerver hueless, there's no ventilating system in the hospitals. The rooms'repainted in white and yellow, light green white, or green color. The patient's clothing were in green pink blue, light green or in white co for. There're not anything special in both decoration and equipments. Most of them used tall beds except in one hospital 2. To the extent of perception of patient's hatch 9round and hospital environment it is presented that they perceived nurse's ability in highest in total human variable, though perceived kindness or etiquette in the lowest otherwise, comparatively high in total average. 3. In the respect of physical environment it is highest perceived of lightening terms, otherwise, lowest perceived of air ventilation and total average became lowest than the one of the original record 4. To ages, in the respect of hatch ground rather old aged mother than the younger one has perceived that nurse would be trusting, in good service character, able, at the same time, liable, Otherwise, in physical environment regardless of age, they perceived lightening in high and remarkably lower in ventilation As a result of the examination of the difference in hospital environment to each age it is appeared of statistical difference at 5% level of ability in the personal environment otherwise little difference as for physical environment 5. In the respect of perceiving level to educational standard it is highly perceived of personal environment for higher ranking group rather than lower group in the educational standard. In case of physical environment it is highly perceived for lower level group rather than higher level group in educational background. The variables which have statistical significance at 5% level are from trusting kindness, etiquette and total kindness, etiquette and total all significance at 5% level are from trusting, kindness, etiquette and total human environment variable in personal environment, otherwise, there's little difference in the physical environment. 6. The perceiving level due to times of admission and accommodation at the hospital would be cleared out as gradual higher perception both physical and personal environment in the hospital. At 5% significant level of the ventilation condition in physical environmental variable it is presented of meaningful difference otherwise, there we have little difference both in Personal variable and other one. 7. In accordance with living standard, the perception degree of personal environment in tee hospital would be inclined to increase to higher living standard on the other hand, in case of the physical environment, the perception level world increase to lower living standard At 5 % level, the trustuariable and total scores in the personal eicuironmectal variable there appeared a meaningful/ significant difference otherwise, there presented little difference both in physical environmental and other variable to the living standard 8. Pertaining to family unit, the mother of an independent family unit perceived highly in all respect of the personal and the physical environment in the hospital rather than the woman of succeeding family unit. At 5 % level there appeared a difference in the respect of kindness and etiquette both in personal environment variable, on the other hand, there hardly marked a difference between other variable and physical environmental one. 9. The degree of perception to comforting level has little connection with a statistical difference the age, educational level hospital admitting times, living standard or family unit. 10. The most effective variable to mother's comforting level will be nurse's ability, reliability, trusting manner, and total physical environment variable in order.

  • PDF

Aveva Marine과 SmartMarine 3D간의 해양 플랜트 3D 배관 CAD 모델의 배치모드 기반 비교 시스템 개발 (Development of a Batch-mode-based Comparison System for 3D Piping CAD Models of Offshore Plants)

  • 이재선;김병철;천상욱;조민철;이광;문두환
    • 한국CDE학회논문집
    • /
    • 제21권1호
    • /
    • pp.78-89
    • /
    • 2016
  • When a plant owner requests plant 3D CAD models in the format that a shipbuilding company does not use, the shipyard manually re-models plant 3D CAD models according to the owner's requirement. Therefore, it is important to develop a technology to compare the re-modeled plant 3D CAD models with original ones and to quantitatively evaluate similarity between two models. In the previous study, we developed a graphic user interface (GUI)-based comparison system where a user evaluates similarity between original and re-modeled plant 3D CAD models for piping design at the level of unit. However, an offshore plant consists of thousands of units and thus a system which compares several plant 3D CAD models at unit-level without human intervention is necessary. For this, we developed a new batch model comparison system which automatically evaluates similarity of several unit-level plant 3D CAD models using an extensible markup language (XML) file storing file location and name data about a set of plant 3D CAD models. This paper suggests system configuration of a batch-mode-based comparison system and discusses its core functions. For the verification of the developed system, comparison experiments for offshore plant 3D piping CAD models using the system were performed. From the experiments, we confirmed that similarities for several plant 3D CAD models at unit-level were evaluated without human intervention.

Bacillus subtilis에서 Bacillus stearothermophilus CGTase의 구성적 발현 (Constitutive Expression of Bacillus stearothermophilus CGTase in Bacillus subtilis.)

  • 허선연;김중균;권현주;김병우;김동은;남수완
    • 생명과학회지
    • /
    • 제14권3호
    • /
    • pp.391-395
    • /
    • 2004
  • B. stearothermophilus NO2의 CGTase 유전자 (cgtS)를 구성적 $P_{JH}$ promoter 하류에 subcloning 하여 재조합 plasmid pIH-CGT1 (8.14 kb)을 구축하고 B. subtilis DB431에 형질 전환하였다. B. subtilis DB431/pJH-CGT1를 5가지 배지(LB, 2${\times}$LB, 5% molasses+2% CSL, CS, LBG)로 flask 배양하여 균체증식과 CGTase발현량 및 분비국재성을 조사하여 최적 배지를 결정하였다. 그 중 〔5% molasses+2% CSL〕 배지에서 9시간에 1.8 unit/$m\ell$의 CGTase가 발현$.$생산되었다. 이 결과를 토대로 3. subtilis DB431/pJH-CGT1를 〔10% molasses + 5% corn steep liquor〕 배지에서 발효조 회분 배양한 결과, 30시간 배양시 CGTase의 최대 발현량은 4.2 unit/$m\ell$, 90%의 분비 효율, 90% 이상의 plasmid 안정성을 나타내었다. 저렴한 산업용 molasses 배지로 발효조 회분배양시 플라스크 배양보다 균체증식과 CGTase 발현량이 2배 이상의 증가된 값을 얻었다.