• Title/Summary/Keyword: Unit Test

Search Result 3,986, Processing Time 0.033 seconds

Performance verification and improvement of the frequency analysis unit for GIS Preventive & Diagnostic Monitoring System (GIS 예방진단시스템 주파수 분석장치 성능개선 및 검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.485-491
    • /
    • 2015
  • This paper shows the design improvement and test model of FAU (Frequency Analysis Unit) in PDD (Partial Discharge Diagnosis system) for 800kV GIS (Gas Insulated Switchgear). We found some problems during operation of previous FAU, such as the aging of fiber-optic converter that can cause communication error, the malfunction of signal analysis circuit etc. And then we solved those problems by design improvement and verified the performance through type test. To monitor partial discharge, the performance of UHF sensor is important but the performance of frequency analysis unit is also very important. So we solved communication error, the malfunction of signal analysis circuit and then increased the operation reliability of FAU by improving fiber-optic converter and signal analysis circuit. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria.

Building Test Codes for Unit Test Automation of Java Programs (단위 테스트 자동화를 위한 자바 프로그램 테스트 코드 구축)

  • Yoon, Hoijin
    • Journal of Software Engineering Society
    • /
    • v.23 no.4
    • /
    • pp.141-149
    • /
    • 2010
  • Agile development is mentioned a lot by developers these days. XP or Scrum is one of the popular development processes, and it says that unit test automation would drive an agile development successful. The success of unit test automation depends on how well to compare an execution result to its own expected result. that is why this paper focuses on the comparison part. This paper introduces how to build test codes for unit testing, and then concludes with mentioning two considerations of unit testing automation. First, test codes for void-typed methods need Mock Framework to monitor their behavior. Second, the comparison of execution results and expected results is hard to implement in case of testing void-typed methods. We check every sentences of a test path to decide if the testing is fail or pass.

  • PDF

Automated Unit-test Generation for Detecting Vulnerabilities of Android Kernel Modules (안드로이드 커널 모듈 취약점 탐지를 위한 자동화된 유닛 테스트 생성 기법)

  • Kim, Yunho;Kim, Moonzoo
    • Journal of KIISE
    • /
    • v.44 no.2
    • /
    • pp.171-178
    • /
    • 2017
  • In this study, we propose an automated unit test generation technique for detecting vulnerabilities of Android kernel modules. The technique automatically generates unit test drivers/stubs and unit test inputs for each function of Android kernel modules by utilizing dynamic symbolic execution. To reduce false alarms caused by function pointers and missing pre-conditions of automated unit test generation technique, we develop false alarm reduction techniques that match function pointers by utilizing static analysis and generate pre-conditions by utilizing def-use analysis. We showed that the proposed technique could detect all existing vulnerabilities in the three modules of Android kernel 3.4. Also, the false alarm reduction techniques removed 44.9% of false alarms on average.

A Flexible Unit Testing Tool for Test Driven Development (테스트 주도 개발을 위한 유연한 단위 테스트 도구로 변경)

  • Jeon, Seok-Hwan;Kim, Jeong-Dong;Baik, Doo-Kwon
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.2
    • /
    • pp.140-144
    • /
    • 2009
  • The efficient test tool is indispensable to the test driven development. The test tool is very helpful to get the advantage of the test driven development. Many traditional automation test tool does not support standard script language and are not suitable to unit test. In traditional unit test tool, a code for the test is added at the source code. Such method makes the complexity of a source code and has a problem which must modify many part of the source code when the test case is changed. In this paper, we present a design technique of a flexible unit testing tool which makes a developer can modify easily the test case by using the standard java script in test driven development. We implement the test tool by this design technique to verify the availability of this technique.

Ljung-Box Test in Unit Root AR-ARCH Model

  • Kim, Eunhee;Ha, Jeongcheol;Jeon, Youngsook;Lee, Sangyeol
    • Communications for Statistical Applications and Methods
    • /
    • v.11 no.2
    • /
    • pp.323-327
    • /
    • 2004
  • In this paper, we investigate the limiting distribution of the Ljung-Box test statistic in the unit root AR models with ARCH errors. We show that the limiting distribution is approximately chi-square distribution with the degrees of freedom only depending on the number of autocorrelation lags appearing in the test. Some simulation results are provided for illustration.

A BizUnit Test Code Generation for Framework-based Web Application (프레임워크기반 웹 어플리케이션을 위한 BizUnit 테스트 코드 생성)

  • Lee, Eun-Young;Choi, Byoung-Ju;Song, Hwa-Jung;Hwang, Sang-Cheol
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.12
    • /
    • pp.899-912
    • /
    • 2009
  • With greater utilization of web application and growth of its market, the function of such application is being expanded With today's increasing demand for high quality software, we see a sharp rise in the interest for web application test. The current trend is that web applications are being developed based on a framework of developmental environment. Hence, as the scope of that framework expands, each module of the entire web application is being configured by the combination of heterogeneous files. The distinctive characteristics of a web application are based on the fact that the framework that is provided in partially completed form controls the structure of all objects of development. The present study defines the web business logic as a minimal unit which has meaning as a unit of application for the web application. In this paper, we define web business logic as a least meaningful execution unit of web applications, propose how to generate automatically the BizUnit test code for it, and analyze the effectiveness of testing of the web application via the BizUnit test codes.

The Existence of Random Walk in the Philippine Stock Market: Evidence from Unit Root and Variance-Ratio Tests

  • CAMBA, Abraham C. Jr.;CAMBA, Aileen L.
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.523-530
    • /
    • 2020
  • The efficient market hypothesis explains the random walk hypothesis suggesting that stock prices are independent of each other, hence, it is impossible to earn abnormal profits. The positive effect of a well-functioning and highly efficient stock market on the performance of an economy motivated the Philippine Stock Exchange to pursue massive modernization initiatives. This research provides evidence of the existence of random walk in the Philippine stock market employing the Augmented Dickey-Fuller (1981) and Phillips-Perron (1988) unit root tests, the Lo-MacKinlay's (1988) conventional variance ratio test, and Chow-Denning's (1993) simple multiple variance ratio test. Results of the ADF and PP unit root tests confirm the necessary condition for a random walk. The Chow-Denning (1993) maximum /z/ statistic and the Wald test statistic as in Richardson and Smith (1991) for the joint hypotheses and the Lo and MacKinlay (1988) individual statistics variance ratio test generally accepted the null hypothesis of a random walk. That is, the unit root and variance ratio tests consistently indicate that the null hypothesis of random walk cannot be rejected. The existence of a random walk in weak-form efficiency can be attributed to market liquidity as a result of continuous development and modernization of the Philippine equity market.

Unit Root Test for Temporally Aggregated Autoregressive Process

  • Shin, Dong-Wan;Kim, Sung-Chul
    • Journal of the Korean Statistical Society
    • /
    • v.22 no.2
    • /
    • pp.271-282
    • /
    • 1993
  • Unit root test for temporally aggregated first order autoregressive process is considered. The temporal aggregate of fist order autoregression is an autoregressive moving average of order (1,1) with moving average parameter being function of the autoregressive parameter. One-step Gauss-Newton estimators are proposed and are shown to have the same limiting distribution as the ordinary least squares estimator for unit root when complete observations are available. A Monte-Carlo simulation shows that the temporal aggregation have no effect on the size. The power of the suggested test are nearly the same as the powers of the test based on complete observations.

  • PDF

Simultaneous Unit Roots Tests for Both Regular and Seasonal Unit Roots

  • Sinsup Cho;Jeong Hyeong Lee;Young Jin Park;Heon Jin Park
    • Communications for Statistical Applications and Methods
    • /
    • v.4 no.3
    • /
    • pp.663-676
    • /
    • 1997
  • We obtain the simultaneous unit roots test statistics for both regular and seasonal unit roots in a time series with possible seasonal deterministic trends. The limiting distributions of the proposed test statistics are derived and empirical percentiles of the test statistics are tabulated for some seasonal periods. The power and size of the test statistics are examined for finite samples through a Monte Carlo simulation and Compared with those of the Lagrange multiplier test.

  • PDF

Study on Vibration Fatigue Analysis of Automotive Battery Supporter (자동차 배터리 지지 구조의 진동 피로 해석에 대한 연구)

  • Ah, Sang Ho
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.4
    • /
    • pp.22-27
    • /
    • 2019
  • In this paper, the vibration load and analysis results for automotive battery supporter were performed to provide efficient vibration tolerance performance prediction methods for single-product vibration tolerance testing, and the major influencing factors and considerations for setting up single-unit vibration tolerance tests were reviewed. A common applicable standard load was applied to efficiently predict the performance of single-unit vibrations through the frequency response analysis technique. The results similar to test results can be predicted by checking vulnerable parts of the vehicle components for vibration loads and applying scale factor to standard loads. In addition, it was confirmed that the test conditions with a frequency generating the same durability severity as the endurance test are needed for accurate prediction of the durability of the single-unit vibration tolerance test conditions, and the acceleration and frequency with the conditions that there is no significant nonlinear phenomena in the vibration system are established during the single-unit vibration tolerance test conditions.