• 제목/요약/키워드: Uniformity ratio of illuminance

검색결과 26건 처리시간 0.022초

표면 검사를 위한 조도 균제도 기반 하이브리드 조명계 설계 (Hybrid Illumination System Design based on Illuminance Uniformity for Surface Inspection)

  • 조은덕;김경범
    • 반도체디스플레이기술학회지
    • /
    • 제18권3호
    • /
    • pp.60-65
    • /
    • 2019
  • In this paper, the hybrid illumination system for effectively detecting surface defects in steel plate with lowcontrast, non-uniformity and featureless is designed based on illuminance uniformity. First of all, characteristics of steel plate defects were considered and typical inspection illumination system is implemented. Optimum illumination parameters for uniformly illuminating an inspection area in the typical illumination system are selected based on the illuminance uniformity and illuminance distribution measurement. The illuminance uniformity and illuminance distribution are measured using an illuminometer based on the arduino. Through illuminance distribution analysis of the typical illumination, an hybrid illumination is designed by fusing bi-directional illumination and coaxial illumination. The hybrid illumination showed higher uniformity ratio and illuminance distribution than the typical illuminations. The hybrid illumination system showed the ability to uniformly illuminate the entire inspection region of steel plate surface.

Illuminance Distribution and Photosynthetic Photon Flux Density Characteristics of LED Lighting with Periodic Lattice Arrangements

  • Jeon, Hee-Jae;Ju, Kang-Sig;Joo, Jai-Hwang;Kim, Hyun-Gyun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권1호
    • /
    • pp.16-18
    • /
    • 2012
  • LED lighting systems that combine lighting capability, emotional and physiological characteristics are required for lighting source and multifunctional applications. In this work, Simulation studies using optical analysis software packages, Light Tools, are presented. This is done to estimate the uniformity ratio of illuminance and photosynthetic photon flux density (PPFD) of the periodic 2D lattice arrangements, such as square, diamond, two-way bias quadrangular, hexagonal, and Kagome lattices, under the same transmissivity, absorptance and reflectivity. It has been found out that the two-dimensional Kagome lattice arrangement exhibited high uniformity ratio of illuminance and PPFD compared to other lattices. Accordingly, these results can be used to guide a design and improve the lighting environment which in turn would maximize the uniform distributions of illuminance.

LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구 (Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires)

  • 이진숙;김원도;김병수;한원탁
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.1-7
    • /
    • 2008
  • 본 연구의 목적은 형광등조명기구와 LED 조명기구와의 물리적 특성을 비교하여 LED조명기구의 기본적인 특성을 분석하는데 있다. 여기서 두가지 조명기구의 균제도 및 휘도분포 측면에서 비교 분석하여 LED조명기구를 건축실내공간에 적용하기 위한 자료를 작성하였다. 연구는 4단계로 나누어 진행하였다. 첫째, 기존의 조명기구와 비교한 LED조명광원의 이론적인 검토를 하였다. 둘째, 연구의 목적에 부합되도록 실험변인을 조절할 수 있는 실물대모형(Mock-up)을 제작하였다. 셋째, 설치된 실물대의형을 이용하여 조명기구별 균제도 휘도분포를 측정하였다. 최종적으로, 기존의 형광등기구와 LED조명기구간의 균제도 휘도분포 특성을 비교분석하였다. 연구결과 LED조명기구가 균제도 0.569로 기존 형광등조명기구의 균제도 0.522보다 높아 균일한 조도분포 특성을 보이고 전반확산이 양호한 것으로 나타났다. 또한 휘도분포를 측정한 결과 LED조명기구가 보다 균일한 휘도분포 특성을 보였고, 벽면의 휘도분포는 형광등조명기구에 의한 최대휘도가 $180.6[cd/m^2]$, LED조명기구는 $155.26[cd/m^2]$로 형광등이 높고, 평균휘도는 형광등조명기구가 $44.32[cd/m^2]$, LED조명기구가 $58.65[cd/m^2]$로 LED조명기구가 높게 나타났다. 이상의 결과로 볼 때, LED조명기구가 형광등조명기구보다 재실자에게 보다 쾌적한 작업환경을 구성할 수 있는 조명이라 판단된다.

염료감응형 태양전지(DSC)와 자연채광의 상관관계 분석-교육공간을 중심으로 (A Correlation Analysis between DSC (Dye Sensitized Cell) and Daylighting-Focusing on Educational Space)

  • 이응직
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.35-47
    • /
    • 2020
  • Due to the large window area, the lighting environment of the educational space between the window and deep part of the room is not uniformly illuminated, and the phenomenon of glare is severe. For this reason, the daylight performance of DSC-BIPV windows was analyzed in order to improve the natural lighting in the educational sector. The method derives the correlation with natural lighting by measurement and simulation. Dynamic simulation confirmed that the average illuminance of the target space was higher at later than the early afternoon. The performance of natural lighting at 40% and 30% transmission of DSC has the effect of significantly reducing the amount of excess light in existing windows. Nevertheless, the actual average illuminance in all seasons corresponds to the standard illuminance of the educational facility, 300 Lux. In addition, the uniformity is also seen through the skylight illuminance ratio.

초등학교 교실의 빛 환경 실측에 관한 연구 (A Study on the Experiment of Luminous Environment in Classroom of An Elementary School)

  • 박경은;김준태
    • 교육시설
    • /
    • 제9권5호
    • /
    • pp.13-21
    • /
    • 2002
  • Daylighting in educational environment is very important as it has an effect on students' performance as well as in their visual health. It is regarded as a good energy conservation method in saving energy used for lighting. This study conducted initial daylight measurements to analyze luminous environment in classrooms of Korean elementary school. The results indicated that the typical classroom had a reasonable level of daylight. However, it also found that the classroom had some problems of the uniformity of illuminance and the contrast of brightness of surfaces in the classroom. It is argued that daylighting design for school classroom should consider these aspects to make daylit classrooms ideal so as to provide comfortable visual environment.

간접 반사 방식의 LED 보안등기구 반사판 설계 (Reflector Design for LED Pedestrian Lighting Using Indirect Reflectance Type)

  • 채성기;정동환;이윤철
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.6-13
    • /
    • 2012
  • In this paper, we took an indirect reflectance type that irradiates light from an LED module, which reflects light from a reflector onto the road. This LED pedestrian lighting design produces minimal glare from a relatively simple structure. Using LightTools 7.2, we conducted a study on the varying shape and curvature of the reflector. In order to further investigate this data, we researched the ratio of the DLOR and ULOR, the average illuminance, and the uniformity of the illumination. Based on this research, we selected optimum conditions to realize the actual LED pedestrian lighting using RELUX software. We found the average illuminance value to be 22[1x] and the illuminance uniformity ratio to be 0.23, which met the criteria of the proposed standards set in KS C 7658. In addition, it also satisfied the criteria of the standards set in KS A 3701 by having TI (Threshold Increment) at 7[%].

조명기구의 배치에 따른 교실의 조도와 에너지 절약 (A Energy Saving and Illuminance of a Classroom due to the arrangement of luminaires)

  • 김이두;오세영;박희두;신종열;이수원;홍진웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2417-2419
    • /
    • 1999
  • Among educational environment, lighting's role is getting more important since it improves the visual tasks, capability of work, and it help to build both balanced mind and body. Also, since students spend most of their time inside rather than outside, students need appropriate illuminance everyday. If optimum illuminance, the color rendering properties and controlled distribution of lighting is given, people can decrease the fatigue of eyes, recover their health, and also, people can maximize their efficiency of work. In this paper, their is a comparison between the real illuminance and illuminance distribution due to the uniformity ratio of 2 or 3 dimensions by simulation.

  • PDF

50W급 LED 보안등용 조명광학계 개발 (Development of Optical System for 50W LED Security Lamp)

  • 정병조;장성환;노용기
    • 한국산학기술학회논문지
    • /
    • 제13권1호
    • /
    • pp.296-305
    • /
    • 2012
  • 본 연구에서는 기존 LED 보안등의 LED 광원 직진성에 의한 눈부심 현상을 개선하고, 조도 균제도를 높게 유지하며, 회전 대칭이 아닌 편축으로 긴 배광 분포를 가지도록 하여 LED 보안등 간에 생기는 광 공핍현상을 해결할 수 있는 보안등용 LED 2차 렌즈를 개발하였다. 개발 광학계는 보안등용 조명 기준에 만족하도록 설계하였으며, 렌즈의 형태는 단일 렌즈로 조명 설계 및 해석 프로그램을 이용한 설계와 분석을 통해 최적화를 하였다. Mock-up을 제작하여 실제 측정을 통해 조도 측정 데이터와 조도 균제도 데이터를 확보하였다.

공간의 특성을 고려한 조도 측정방법에 관한 연구 (The Measurement Method of the Illuminance Considering Space Characteristics)

  • 주근탁;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.3-7
    • /
    • 2005
  • A lighting method of our county is ordinary center concentration form. Therefore, it is usally used the Five Point Method, Multiplicity Method of KS, and Four Point Method of IES to measure a space illuminance. We can use the Five Point Method of KS when we measure a uniformity ratio or activities that happen in space is more sensitive than whole illumination. In addition, we can use the Multiplicity Method of KS and Four Point Method of IES when we measure whole illuminance like mean illuminance. Such method of measurements should be used exactly according to the kinds of space and activities.

  • PDF

아파트의 지하주차장의 조명 운영개선 (Improvement of Underground Parking Garages Lighting in Residential Areas)

  • 장수정;최안섭;최성열
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.163-168
    • /
    • 2004
  • The improvement of perspectives on dark and limited underground space could be an important factor in successful underground space development. Current trend in the apartment underground parking lot requires not only quantitatively energy efficient design and operation, but also qualitative improvement of the space. For this, we need to consider two factors: Firstly, to understand the characteristics of the fluorescent lamp. Secondly, to improve the uniformity ratio of illuminance. In winter season, a way to keep the uniformity and a method not to lower the indoor illuminance level by cold ambient air. Therefore, a change in interval and arrangement of the lighting fixtures is required. Also, in their operation, current time-fixed control method needs to be changed into the control that method considers the use pattern.

  • PDF