• 제목/요약/키워드: Underground water

검색결과 1,335건 처리시간 0.026초

어독성 시험에 의한 그라우팅재의 수질오염 평가 (The Evaluation of Toxic Effect of Grouting Materials by Fish Poison Test)

  • 천병석;김진춘;이영근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.156-161
    • /
    • 1998
  • As grouting materials for ground improvement, silicate materials such as water glass, silica-sol and so forth are used worldwide. However, they may pollute underground water. In this study, fish poison test(Korean standard industrial code KS M 0111) which estimates toxicity for fish is applied to evaluate the toxic effect by grouting materials. From the test result of the sample made of LW, LC50(Median Lethal Concentration) reaches within 24 hours. In case of the silica-sol, it does not even in 96 hours. Therefore, we can conclude that the sililca-sol grouting method is more free from the danger of underground water pollution. From the result that the mortality of fish under the condition of pH 8.6 is 0% within 96 hours, the groundwater can be saved by controlling pH below 8.6 for the grouting in the field.

  • PDF

5678 서울도시철도 지하역사의 라돈 관리 현황 (Current Status of Radon Management in the 5678 Seoul Metropolitan Rapid Transit Subway)

  • 김준현;윤현식;서강진;우희영;김만화;박종헌
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1306-1312
    • /
    • 2011
  • Underground Subway station's air pollutants are introduced from the indoor or outdoor. And Radon is a major pollutant in the subway station. Radioactive substances Radon is occuring naturally in granite tunnel wall and underground water. Especially inert gas Radon that causes lung cancer in human is anywhere but 5678 S.M.R.T. tunnels deep and pass through the granite plaque have a lot of Radon. The Radon concentration is determined by the following reasons : radon content of soil and concrete, underground water, ventilation, pressure difference, building structure, temperature, etc. So Radon concentration is hard to predict. And we can't only ventilate owing to era of high oil prices. This study focuses on our efforts for the reduction of Radon concentration. And the purpose is to provide basically datas of specially managed 15 subway station's Radon concentration.

  • PDF

원유 저장용 지하공동의 건설중 점토 그라우팅에 의한 지하수 제어 (Countrol of Groundwater by Clay Grouting in Undergroun Excavation of Oil Storage Caverns)

  • 김치환;박창우;이석천
    • 터널과지하공간
    • /
    • 제3권1호
    • /
    • pp.24-32
    • /
    • 1993
  • Groundwater movement is one of the most important elements in the construction and management of underground oil storage cavern. To control the groundwater flow, grouting is run in parallel with water curtains. But as traditional grouting is conducted within cavern before and after excavation, the effect of grouting is delayed and the injection sphere is limited in the rock mass. Therefore, it is desirable to introduce a more extensive and effective grouting. This article is to present the caly grouting, which was the first to be carried out in the construction of underground caverns for oil storage in Japan. After conducting the clay grouting, the effect was confirmed by ground water level and infiltration quantity to the caverns.

  • PDF

Comparison of hydrochemical informations of groundwater obtained from two different underground storage systems

  • Lee, Jeonghoon;Kim, Jun-Mo;Chang, Ho-Wan
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.110-113
    • /
    • 2002
  • Statistical- based, principal component analysis (PCA) was applied to chemical data from two underground storage systems containing LPG to assess the usefulness of such technique at the initial stage (Pyeongtaek) or middle stage (Ulsan) of hydrochemical studies. For the first case, both natural and anthropogenic contamination characterize regional groundwater. Saline water buffered by Namyang lake affects as a natural factor, whereas cement grouting influence as an artificial factor. For the second study area, contaminations due to operation of LPG caverns, such as disinfection activity and cement grouting effect, deteriorate groundwater quality. This study indicates that principal component analysis would be particularly useful for summarizing large data set for the purpose of subsurface characterization, assessing their vulnerability to contamination and protecting recharge zones.

  • PDF

Hi-FA(유동성 및 점성 개질제)를 이용한 지하공동 보강사례 (Reinforcement of underground cavities by Hi-FA(High performance and Multi functional Agent))

  • 임해식;박영호;백규호;이용준;박수용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.676-686
    • /
    • 2010
  • Damage Cases of variously type are reported that the ground subsidence is caused by the underground cavities at structure and construction works in lime stone or abandoned zone. A underground cavities by direct for zone having an effect on structure have been filled with cement agents. But this measure is urgently needed in materials and work methods, because ground water pollution at water down fillings and flow out, ground disturb at high participle, damage of farms and fishery. The research confirm application of filling method and filling materials of environmentally friendly and economical by Hi-FA new materials have both liquidity and viscosity from case reinforcement in APT site, Gunsan.

  • PDF

심지층 고준위 핵폐기물 처분용기의 열응력 해석 (Thermal Stress Analysis of Spent Nuclear Fuel Disposal Canister)

  • 하준용;권영주;최종원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.617-620
    • /
    • 1997
  • In this paper, the thermal stress analysis of spent nuclear fuel disposal canister in a deep repository at 500m underground is done for the underground pressure variation. Since the nuclear fuel disposal usually emits much heat and radiation, its careful treatment is required. And so a long term safe repository at a deep bedrock is used. Under this situation, the canister experiences some mechanical external loads such as hydrostatic pressure of underground water, swelling pressure of bentonite buffer, and the thermal load due to the heat generation of spent nuclear fuel in the basket etc.. Hence, the canister should be designed to designed to withstand these loads. In this paper, the thermal stress analysis is done using the finite element analysis code, NISA.

  • PDF

지하수의 영향을 고려한 지하공동구조체의 동적응답 (Dynamic Response of Underground Openings Considering the Effect of Water Saturation)

  • 김선훈;김광진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 가을 학술발표회논문집
    • /
    • pp.281-288
    • /
    • 2000
  • Three-dimensional dynamic analysis of underground openings subjected to explosive loadings considering the effects of water saturation is carried out in this study. The problem considered in this study is an unlined circular tunnel subjected to a finite cylindrical charge placed at the center of the proposed tunnel. The surrounding rock mass is assumed to be the limestone with 13.5% of porosity. Two calculations are compared using an identical explosive charge; the first in dry rock of 13.5% porosity, the second in the identical rock, but in a fully saturated condition. It is shown that underground openings in saturated porous medium could be significantly more vulnerable to the potential damages associated with high motions and shear failure than those in dry medium.

  • PDF

화상계측에 의한 지중 전력케이블의 수트리 열화에 관한 연구 (A Study on Water Tree Degradation Using Image Measurement in Underground Power Cables)

  • 김덕근;임장섭;이진
    • 한국전기전자재료학회논문지
    • /
    • 제13권12호
    • /
    • pp.1063-1068
    • /
    • 2000
  • Water treeing in underground distribution power cable is not easy to observe by nondestructive method and it has very complex patterns. This study describes the principles and practices of a continuous observation of initiation and growth of tree in polymeric insulation material using an image measurement technique. Using this technique we could observe water tree and the growing process of electrical tree due to the water tree and the growing process of electrical tree due to the water tree. All of these growing process is analyzed quantitatively by image measurement program composed of borland c++. We fabricated the thin film type specimen to observe water tree easier and also the needle electrode was prepared by etching method using electrolytes. Initiation and the growth of three was observed somewhat different depending on the applied voltage and the water electrode. AgNO$_3$solution electrode accelerates the initiation and the growth of water tree, compared to those of distilled water electrode. The water and the electrical tree occurred by water tree has discontinuous growth characteristic.

  • PDF

지하수 열원 열펌프 개발을 위한 지하수 온도의 변화 특성 연구 (A Study on the Variation of Ground Water Temperature for Development of Ground Water Source Heat Pump)

  • 남현규;김영일;서정아;신영기
    • 한국지열·수열에너지학회논문집
    • /
    • 제1권2호
    • /
    • pp.1-6
    • /
    • 2005
  • Ground water source heat pumps are clean, energy-efficient and environment-friendly systems for cooling and heating. Although the initial cost of ground water source heat pump system is higher than that of air source, it is now widely accepted as an economical system since the installation cost can be returned within a short period of time due to its high efficiency. In a ground water source heat pump system, the variation of the ground water temperature is an important factor that influences the system performance. In this study, variation of the ground water temperature of a single well system is studied experimentally for various operating conditions. When ground water flow exists in the underground, the returned water exchanges heat efficiently with the ground and the temperature of the ground water remains nearly constant. Hence the short circuit problem is minimized. If an active flow of ground water flow exists in the underground, a singe well heat pumps system will be free of short circuit problem and can operate with high performance.

  • PDF

Estimation of greenhouse gas emissions from an underground wastewater treatment plant

  • Kyung, Daeseung;Jung, Da-Yoon;Lim, Seong-Rin
    • Membrane and Water Treatment
    • /
    • 제11권3호
    • /
    • pp.173-177
    • /
    • 2020
  • Wastewater treatment plants (WWTPs) have been recognized as one of the significant greenhouse gas (GHG) generators, due to the complex biochemical reaction and huge consumption of energy and materials. Recently, WWTPs have been built underground and they will be confronted with the challenges of mitigating GHG emissions and improving the quality of treated wastewater. Here, we focus on estimating GHG emissions to set up effective management plans for a WWTP built underground. First, we apply the process-based life cycle assessment (LCA) with an inventory database of the underground WWTP for a case study. Then, we identify significant factors affecting GHG emissions during service life using sensitivity analysis and suggest the proper tactics that could properly reduce GHG emissions from the WWTP.