• Title/Summary/Keyword: Underground space construction

Search Result 915, Processing Time 0.035 seconds

Standardization of Underground Shopping Center Address System for the Three-Dimensional GIS-based Emergency Management (3차원 GIS기반의 소방방재를 위한 지하상가 주소체계 표준화)

  • Ha, Byeong Po;Kang, In Joon;Hong, Soon Heon;Park, Dong Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.63-69
    • /
    • 2014
  • Due to population growth and urban development in construction technology has expanded living space, underground construction as public transport as has been extended to the ground and underground urban traffic congestion increases. This underpass Stations sphere of influence this development was the center of the living space, space-time became a cultural space. However underpass ground space and time and space are enormous difficulties in contrast visibility due to smoke when light levels are low fire occurs, momentary loss of judgment errors due to a sense of orientation, rapid diffusion and ambient oxygen deficiency due to acquisition limitations, such as the Open resulting in property damage and personal injury. The purpose of this study is to analyze the existing system with respect to the address of the underground shopping center and system for presenting an address to the underground shopping mall in the basement of the straight and circular in connection with the street name address. Also can be known only to evacuate their citizens to address the position in the event of a fire inside the basement through the underground shopping mall address standardization system, the fire department only address exact location is being judged will be identified.

Suitability valuation of Underground Facility Construction Using GIS (GIS를 활용한 지하시설물 시공의 적정성 평가)

  • 김감래;이재기;임건혁
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.465-469
    • /
    • 2004
  • The purpose of this study is to evaluate suitability of Underground Facility Construction in great land development area. Because there are the construct of national integration information control system and the advance of information technique, the necessity that construct the UIS to manage the urban space systematically is enlarged. In the purpose that we prepare the base of underground facility management system by driving the step digitalizing facilities buried underground and protect urban safety accident, we introduce the GIS in land development area. This study proposes the improvement direction by examining the outcome through the driving method and the outcome analysis.

  • PDF

Work Time of Basement Composite Wall Form Assembly by Work Time Analysis (작업분석을 통한 합벽거푸집 구성 요소별 작업소요시간에 관한 연구)

  • Heo, Kyoung-Moo;Kim, Myoung-Hyun;Kim, Tae-Hui;Kim, Jae-Yeob;Kim, Gwang-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.9-13
    • /
    • 2009
  • Recently, construction in downtown is often done closely at the adjacent building. In this case, underground construction need to Basement Composite Wall(BCW) construction. However, generally, during the construction process of BCW form works have many problems that are narrow working space and inefficient time consuming. Despite of these problems, there was no quantitative research for the work time of BCM assembly. Therefore, in this study, work time of CBW form assembly in underground construction is identified by the work analysis. The results of this study reveal that buttress work of basement form take lots of time in the entire work process of Basement Composite Wall form assembly.

  • PDF

Conflict analysis and countermeasures due to construction of very-deep tunnels in urban area (도심지 대심도 터널건설에 따른 갈등분석 및 대책)

  • Moon, Joon-Shik;Jeon, Kichan;Kim, Young Geun;Moon, Hoonki
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.371-384
    • /
    • 2021
  • Underground space, especially very-deep tunnel development in urban area, is a good alternative to solve the problem of insufficient ground space, and the need for underground space development is steadily increasing. However, due to the complex and time-consuming nature of design and construction, public conflicts related to the deep tunnel project are getting aggravating and more complex. In addition, since the public budget is mainly invested, when civil complaints arise, they often respond passively, resulting in amplification of conflicts or prolonging the deadlock in many cases. In this study, by analyzing the progress of major conflicts related to the construction of very-deep tunnels in urban area, the causes of conflicts, factors prolonging conflicts, and solutions are reviewed. Through a survey targeting ordinary citizens and tunnel experts, thoughts about the deep tunnel construction and major conflict factors were analyzed, and suggestions for minimizing conflicts were presented. The results of this study can be used to prepare alternatives such as various public involvement measures and improvement of project procedures to form a civic consensus on the construction of very-deep tunnels, and to prepare measures to improve prejudice against very-deep tunnels.

A Study on the Selection Method of Foundation Type in the Underground Parking Lot of Apartments (공동주택 지하 주차장 기초형식 선정방법에 관한 연구)

  • Im, Nam-Gi;Lee, Yeong-Do;Bae, Yong-Hwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.109-116
    • /
    • 2004
  • Normally easy task of plat in urban architecture is that using underground full of activities for increase building site efficiency. Especially for using underground space for the parking lot. Also utilize underground is more increase for fulfill requirement in modern society considered with environmental friendly architecture. The primary objective of this study is to apply analyzed formal foundation type for selecting the optimum type of parking lots considered with structural stability, economical efficiency, construction efficiency, construction duration. This study aim to on criteria decided through the questionaries for the selection considered with in the scale of second stories parking lots underground, parking volume is 80 and reinforced concrete structure. The bearing capacity is 6~8m and downward from surface, healthy ground bearing capacity is 40 t/m2. This study comparative analysis and discuss economical efficiency, construction efficiency, construction duration based constructivist stability which applied Single foundation, Mat foundation, Drop Mat foundation. The result of this study is as follows: First, the result of economical efficiency is that on the basis of single foundation, Drop Mat foundation is 1.88, Mat foundation 2.04 as a comparative analysis on the basis of total construction cost included material cost, labor coast and machinery cost. Second, the result of construction efficiency order is single foundation, Drop Mat foundation, Mat foundation as a comparative analysis on the based connected characteristics. Third, the result of construction duration is that on the basis of Mat Foundation, Drop Mat foundation is 1.33, single foundation is 1.87 as a comparative analysis Critical Path. Forth, Each foundational type characteristics order through the matrix method is that overall each formal type of foundation contraries at economical efficiency and construction efficiency, construction duration. Also expect contradiction between engineers and owners due to engineer pursuit construction duration and ewer to begin with economical efficiency. Fifth, The selection of suitable foundation formal type needs that based consider project characteristic and field condition as according to above result of a comparative analysis. As a result, a comparative analysis economical efficiency, construction efficiency, construction duration of Mat foundation, Drop Mat foundation, single foundation with 3Bay reinforced structure underground parking lots on the healthy ground.

A Field Survey on the Risk Management Information System on the Underground Space - Focused on Fire Protection Assessment System on The Underground Shopping Mals - (지하공간의 위험관리정보시스템에 관한 조사 연구 - 지하가의 화재예방평가시스템 중심으로 -)

  • Park, Jong-Keun;Roh, Sam-Kew
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.4 s.7
    • /
    • pp.117-122
    • /
    • 2002
  • A large number of accidents at an underground place have been happening, including the gas explosion under construction of subway, the fires of underground utility and underground shopping malls, and other explosion, at home and abroad recently. These accidents make the function of a city ineffective due to the paralyses of electricity and communications net as well as the loss of property, and cause people to feel unsecured with accompaniment of a heavy of toll of lives. This study suggests safety assessment items and fire protection assessment technique for underground shopping malls by extracting dangerous elements in the management stage through examination of related accidents, documents and present conditions.

A numerical study on evaluation of unsupported pillar strength in the room and pillar method (주방식 공법에서 무지보 암주의 강도 산정에 관한 수치해석적 연구)

  • Lee, Chulho;Chang, Soo-Ho;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.4
    • /
    • pp.443-453
    • /
    • 2013
  • This study aims to evaluate the mechanical behaviors of unsupported rock pillars in a room-and-pillar underground structure by a series of numerical analyses. In addition, rock pillar strengths estimated by a few empirical equations proposed for underground mines are compared with those from numerical analyses. Based on the results from the numerical analysis, the ratio of pillar strength to rock mass strength increases as the ratio of the width of a pillar to its height becomes bigger. It means that higher ratio of pillar width to its height is much more favorable for stabilizing a room-and-pillar underground structure. Especially, unsupported pillar strengths estimated from numerical analyses are higher than rock mass strength when the ratio of pillar width to height is approximately over 1.5. It is also found that the choice of an empirical equation appropriate for a given geometric condition of a pillar is important for its feasible application to the stability analysis of a pillar in the room-and-pillar method.

Development of finite element analysis model for multi-step excavation problem (시공단계를 고려할 수 있는 유한요소 해석 모델 개발)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.6 no.4
    • /
    • pp.326-334
    • /
    • 1996
  • In underground construction the multi-step excavation sequence is commonly adopted for the convenience of the underground work. A numerical simulation method which is capable of analyzing the effects of excavation sequence on the stability of the opening is greatly needed. In this study a two dimensional finite element code was developed based on the effective numerical algorithm for the multistep excavation. The practical applicability of the model was verified for the simplified excavation sequences.

  • PDF

Status and Trend of Foreign Underground Data Centers (해외 지하 데이터센터의 현황과 동향 분석)

  • Lee, Chulho;Choi, Soon-Wook;Kang, Tae-Ho;Chang, Soo-Ho
    • Tunnel and Underground Space
    • /
    • v.29 no.1
    • /
    • pp.52-63
    • /
    • 2019
  • It is highly in demand to establish a bunker-type underground data center to ensure the safety of national critical data, such as financial information and medical information, and prevent those outflow of national important data. In particular, the security of a data center which is a key national structure has become a social issue due to EMP weapon and earthquakes, but data centers in the nation have not been able to deal with it properly. Therefore, it is necessary to develop an underground data center that is safe from human-induced and natural disasters while reducing power costs by utilizing the benefits of underground spaces such as constant temperature and isolation. In this analysis, the status and trends of data centers around the world were analyzed and based on those trend analyses, the research strategy for underground data center were discussed.

Stability evaluation and microseismic monitoring around Large Underground Oil Storage Cavern in Over-stressed Rock Mass (과지압 암반 내 대규모 지하 유류비축기지 안정성 평가 및 Microseismic 계측)

  • Lee Hee-Suk;Lee Dae-Hyuck;Kim Ho-Yeong;Hong Jee-Soo;Choi Young-Tae;Kim Seok-Jin;Park Yeon-Jun
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.189-201
    • /
    • 2005
  • Brittle failure has been detected in over-stressed rock mass during the construction of oil storage cavern. The main characteristics of stress induced brittle failure of the site are introduced. Various evaluation and measures are sought to stabilize the over-stressed rock mass. The major results from numerical analysis of the cavern are presented, and from current microseismic monitoring to detect hazard from brittle failure are presented.

  • PDF