• 제목/요약/키워드: Under-Water Treatment

Search Result 1,627, Processing Time 0.028 seconds

Analysis of Proper Linked Treatment Load Using GPS-X Simulation (GPS-X 시뮬레이션을 이용한 적정 연계처리부하량 분석)

  • Kim, Sungji;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.244-250
    • /
    • 2019
  • Due to the industrial development and population growth, it has recently been shown that there are many problems caused by the rinked treatment water in local goverments and sewage treatment plants. The rinked treatment water has a characteristic of low flow rate and high concentration unlike general sewage. These characteristics increase sewage treatment difficulty and sewage treatment fee of sewage treatment facilities. Among the many influencing factors that increase sewage treatment unit cost, 'linked treatment load/design inflow load (%)' was derived as the most correlated factor. Through the selection and modeling of sewage treatment plants, the excess scope of design discharge water quality was investigated under the conditions of temperature and the conditions of 'linked treatment load/design inflow load (%)' taking into account the effects of the four seasons. The study found that for TN, 'linked treatment load/design inflow load (%)' was 19.7%, 22.6%, 25.1%and 27.7%, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$. In case of TP, 'rinked treatment load/design inflow load (%)' was 10.7%, 12.2%, 15.6% and 17.5% at $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$, and $25^{\circ}C$, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$.

The effect of intermittent feeding and cold water on performance and carcass traits of broilers reared under daily heat stress

  • Erensoy, Kadir;Noubandiguim, Moise;Sarica, Musa;Aslan, Resul
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.12
    • /
    • pp.2031-2038
    • /
    • 2020
  • Objective: This study aimed to determine the effect of intermittent feeding and cold water on performance and carcass traits in broiler chickens between 4 to 6 wk of age exposed to daily high temperature. Methods: Broilers were assigned to four treatment groups according to a 2×2 factorial design between 22 to 42 d of age (80 broilers per treatment, 4 replications). Broilers were divided into two main groups as feeding type (ad-libitum [AL] and intermittent [IF] for 6 h daily) and sub-groups as water temperature (normal [NW], 24.9℃ and cold [CW], 16.4℃). Heat treatment was applied between 11.00 to 17.00 h daily between 22 to 42 d of age. Results: Live weight at 6th wk was not affected by feeding type and water temperature, but the live weight was significantly higher in IF chickens at the 5th wk (p<0.05). Average weekly gain of IF broiler chickens were higher compared to AL group at 4, 5, and 6 wk of age (p< 0.05). Although feeding type did not affect feed intake in 4 and 5th wk, feed intake was higher in IF chickens at 6th wk (p<0.01). In addition, feeding type and water temperature did not affect feed conversion ratio and interactions were not significant (p>0.05). Water temperature had no significant effect on heart, liver, gizzard, and abdominal fat percentages (p>0.05). Conclusion: It is concluded that IF increased the average weekly gain in chickens reared under daily heat stress for 6 h between 22 to 42 d of age. IF in hot environmental conditions slightly increased performance without adversely affecting health, welfare, and physiological traits, whereas CW implementation had no significant effect on performance. It can also be said that IF suppresses a sudden increase in body temperature depending on age and live weight.

Bisphenol-A Removal in Conventional Water Treatment Systems (정수처리공정에서 bisphenol-A의 제거에 관한 연구)

  • 김혜리;이윤진;박선구;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.1
    • /
    • pp.59-64
    • /
    • 2004
  • This study was carried out to investigate influencing factors of bisphenol A(BPA) removal characteristic in conventional water treatment systems to be connected with coagulation, sedimentation, filtration and disinfection. The result are summarized as follows; In BPA removal, optimal doses of PAC, alum, ferric chloride were 7.5 mg Al/L, 10.0 mg AI/L, 15.0 mg Fek. PAC was most effective coagulant to remove BPA. In coagulation process, BPA removal efficiency were increased about 2% by adjusting pH of raw water as 6. At temperature rise 1$0^{\circ}C$, BPA removal efficiency were increased 0.94%. but BPA removal efficiency in sand filtration process were under 1 %ie, so that BPA was almost not removed. At free chlorine dose 1, 2 mg/L, the reaction rate constant k in the BPA removal have been calculated to be 0.397, 0.953 min$^{-1}$ . At free chlorine dose 1, 2 mg/1-, degradation reaction of BPA was completed during 10 min and BFA removal efficiencies were 97.66, 99.99% at this time.

Compression and Dewatering of Chinese Cabbage (배추의 압축탈수특성에 관한 연구)

  • Kim, Y.J.;Lee, D.H.;Lee, Y.B.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.1
    • /
    • pp.3-8
    • /
    • 1994
  • An experiment on the expression and dewatering of chinese cabbage was conducted in order to investigate its dewatering behavior. Chopped cabbage was packed into cylinder and pressed by piston upto the predetermined pressure on Instron-1000. The rates of dewatering were affected domintantly by the applied pressure, but not significantly by the packed amount of cabbage in the cylinder. The pressure effect was increased very abruptly at first, but the increase rate was very low at high pressure greater than 20 MPa, showing great deviation from linear dependence of flow rate on pressure in Darcy's Law. Therefore, water expression from cabbage was not Newtonian flow of water through cell wall. In fact, the squeezed water contained a lot of solid particles, about 3% of solid cabbage particles, showing destruction of cell wall. It appeared that compression and dewatering of vegetable wastes in the low pressure. under 20 MPa, is more desirable for later treatment of the dewater. More researches are needed in order to develop a treatment method for the solid particles in the expressed water before an expeller treatment system can be applied to vegetable wastes.

  • PDF

Computation of Irrigation Interval and Amount as affected by Growing Substrate and Soil Depth Planted with Zoysia japonica in Green Roof during a Dry Summer (여름철 무강우 시 들잔디 옥상녹화 식재지반에 따른 관수주기 및 관수량 산정)

  • Ju, Jin-Hee;Bae, Gyu-Tae;Kim, Won-Tae;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.21 no.3
    • /
    • pp.289-296
    • /
    • 2012
  • The purpose of this study was to identify the irrigation intervals and the amount of suitable growing substrate needed to achieve the desired shallow-extensive green roof system during a dry summer in Korea. In terms of treatment, three types (SL, $P_6P_2L_2$, $P_4P_4L_2$) with varying soil mixture ratios and two types (15 cm, 25 cm) with varying soil depths were created. The results have been analyzed after measuring growth and soil water contents. The difference of growth by treatment was significant in terms of green coverage, height, leaf width and photosynthesis. In measurement of chlorophyll content, no difference was detected when measured against soil depth. According to the growth measurement of Zoysia japonica with respect to differing soil mixture ratios in the 15 cm-deep treatment, a statistical difference was detected at the 0.05 significance level in photosynthesis. In case of green coverage, height, chlorophyll content and leaf width, no statistical significance was observed. In case of the 25 cm-deep treatment, a statistical significance was observed in height and photosynthesis. In terms of green coverage, chlorophyll content and leaf width, no statistical significance was detected. In comparisons of soil moisture tension and soil water contents, the irrigation interval and amount were 8 days and 14.9 L in the SL (15 cm) treatment, respectively. The irrigation interval showed for 10 days a 1.3-fold increase, and the irrigation amount was 27.4 L 1.8-fold more than SL (25 cm), respectively. For $P_6P_2L_2$ (15 cm) treatment, the irrigation interval and amount were 12 days and 20.7 L, respectively. However, an irrigation interval under $P_6P_2L_2$ (25 cm) was for 15 days 1.3 times longer than $P_6P_2L_2$ (15 cm), and an irrigation amount of 40 L was 1.9 times more than that under $P_6P_2L_2$ (15 cm). In $P_4P_4L_2$ (15 cm) treatment, it was indicated that the irrigation interval was 15 days, and the irrigation amount was 19.2 L. It was not needed to irrigate for 16 days under $P_4P_4L_2$ (25 cm) treatment during the dry summer and the longest no-rain periods. The irrigation interval and amount under $P_4P_4L_2$ were 1.8-fold and 1.3-fold, respectively, more than SL treatment as affected by soil mixture ratio. Comparatively $P_4P_4L_2$ had more 1.3-fold and 0.9-fold in irrigation interval and amount more than $P_6P_2L_2$. Therefore, it can be noted that different soil depth and soil mixture ratios had a significant effect on the irrigation interval and amount.

Full-scale Case Study on the Relationship between Surface Characteristics of GAC and TOC Removal (입상활성탄의 표면특성과 TOC제거와의 상관성 연구)

  • Baek, Youngae;Joe, Woohyun;Hong, Byungeui;Kim, Kwangho;Choi, Young-june
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.323-328
    • /
    • 2008
  • During the full-scale water treatment operation at "G" Water Treatment Plant in Seoul, we investigated changes in pore volume distribution and specific surface area of GAC with time. The pore volume of the used GAC decreased to the level below 0.6 cc/g while that of the brand new GAC was ranged 0.7~0.9 cc/g. The specific surface area of GAC pores changed within the range between $1100{\sim}1200m^2/g$ and $700{\sim}800m^2/g$. Bacteria attached to the surface of GAC shows a gradual increase ($0.4{\time}10^6{\sim}8.5{\time}10^6CFU/g$) under scanninig electron microscope (SEM). TOC removal was enhanced due to growth of the attached bacteria on GAC. It was found that TOC removal was closely related with physical parameters (pore volume, specific surface area) linearly under the investigated conditions. The used GAC need to be exchanged into new one or re-generated to remove organic matters (TOC) effectively from the finished drinking water.

Korean Lignocellulosics and Portland Cement as a Structural Material (건축재로 국산목질과 포틀랜드 시멘트)

  • Ahn, Won-Yung;Moslemi, Ali A.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.36-46
    • /
    • 1984
  • In order to investigate the inhibitory index (I) and the effects of hot water extraction treatments and addition of accelerators on the index in hardening of Korean lignocellulosics, portland cement (Type I) and water system, hydration tests were carried out on 8 Korean lignocellulosics, namely, Pinus densiflora, Pinus rigida, Pinus koraiensis, Abies holophylla, Larix leptoiepis, Populus alba-glandulosa, rice husk and rice stalk with or without hot water extraction or chemical additives. The inhibitory index of Pinus densiflora and Pinus rigida found to be suitable under limited conditions for composite without any treatment. With hot water treatment rice husk, Pinus koraiensis, Larix leptolepis, and A hies holophylla were reclassified from not suitable to suitable under limited conditions. Combining hot water extraction with chemical addition of accelerator, calcium chloride of magnesium chloride, Populus alba-glandulosa, Larix leptolepis, and Pinus rigida became highly suitable.

  • PDF

Evaluation of inactivation kinetics on pathogenic microorganisms by free chlorine/UV hybrid disinfection system (전해 염소수/자외선 결합 시스템을 이용한 병원성 미생물의 불활성화 키네틱스 평가)

  • Seo, Young-Seok;Kim, Aerin;Cho, Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.379-388
    • /
    • 2019
  • Chlorination and UV illumination are being widely applied to inactivate a number of pathogenic microbials in the environment. Here, we evaluated the inactivation efficiency of individual and combined treatments of chlorination and UV under various aqueous conditions. UV dosage was required higher in waste water than in phosphate buffer to achieve the similar disinfecting efficiency. Free chlorine generated by electrolysis of waste water was abundant enough to inactivate microbials. Based on these, hybrid system composed of sequential treatment of electrolysis-mediated chlorination and UV treatment was developed under waste water conditions. Compared to individual treatments, hybrid system inactivated bacteria (i.e., E. coli and S. typhimurium) and viruses (i.e., MS-2 bacteriophage, rotavirus, and norovirus) more efficiently. The hybrid system also mitigated the photo re-pair of UV-driven DNA damages of target bacteria. The combined results suggested the hybrid system would achieve high inactivation efficiency and safety on various pathogenic microbials in wastewater.

Iron and manganese removal in direct anoxic nanofiltration for indirect potable reuse

  • Jin, Yongxun;Choi, Yeseul;Song, Kyung Guen;Kim, Soyoun;Park, Chanhyuk
    • Membrane and Water Treatment
    • /
    • v.10 no.4
    • /
    • pp.299-305
    • /
    • 2019
  • Managed aquifer recharge (MAR) systems are gaining interest as an alternative to conventional water resources. However, when the water recovered in MAR systems, dissolved iron and manganese species may easily oxidize and they cause well screen clogging or require abandonment of extraction wells. In this study, both oxic and anoxic conditions were analyzed to verify the feasibility of the membrane filtration performance under various solution chemistries. The fouling mechanisms of the metal ions under anoxic conditions were also investigated by employing synthetic wastewater. The fouled membranes were then further analyzed to verify the major causes of inorganic fouling through SEM and XPS. The newly suggested anoxic process refining existing membrane process is expected to provide more precious information about nanofiltration (NF) membrane fouling, especially for demonstrating the potential advantages to chemical-free drinking water production for indirect potable reuse.