Browse > Article
http://dx.doi.org/10.17663/JWR.2019.21.3.244

Analysis of Proper Linked Treatment Load Using GPS-X Simulation  

Kim, Sungji (Department of Civil Engineering, Seoul National University of Science and Technology)
Lee, Jiwon (Department of Civil Engineering, Seoul National University of Science and Technology)
Gil, Kyungik (Department of Civil Engineering, Seoul National University of Science and Technology)
Publication Information
Journal of Wetlands Research / v.21, no.3, 2019 , pp. 244-250 More about this Journal
Abstract
Due to the industrial development and population growth, it has recently been shown that there are many problems caused by the rinked treatment water in local goverments and sewage treatment plants. The rinked treatment water has a characteristic of low flow rate and high concentration unlike general sewage. These characteristics increase sewage treatment difficulty and sewage treatment fee of sewage treatment facilities. Among the many influencing factors that increase sewage treatment unit cost, 'linked treatment load/design inflow load (%)' was derived as the most correlated factor. Through the selection and modeling of sewage treatment plants, the excess scope of design discharge water quality was investigated under the conditions of temperature and the conditions of 'linked treatment load/design inflow load (%)' taking into account the effects of the four seasons. The study found that for TN, 'linked treatment load/design inflow load (%)' was 19.7%, 22.6%, 25.1%and 27.7%, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$. In case of TP, 'rinked treatment load/design inflow load (%)' was 10.7%, 12.2%, 15.6% and 17.5% at $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$, and $25^{\circ}C$, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$.
Keywords
Linked Treatment; Public Sewage Treatment Plant; Sewage Treatment Unit Price; GPS-X modeling;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Kim, YH, Park, HD, Kim, GT, Kang, MS, Ahn, CH, Ji, HM, Kim, IH, Chae KJ(2007). Effects of Connected-Influent on Biological Treatment in Municipal Wastewater Treatment Plant, J. of Korean Society of Environmental Engineers, 2007(12), pp. 72-78 [Korean Literature]
2 Ministry of Environment(MOE) (2011). Study on appropriate treatment & management of the public sewage treatment works entering the industrial wastewater.
3 Ministry of Environment(MOE) (2014a). Guideline for operation and management of public sewage system.
4 Ministry of Environment(MOE) (2014a). Guideline for operation and management of public sewage system.
5 Jeong, CH, Sim, YS, Kim, TH, Park, CH(2004). Evaluation of External Carbon Source on the 2 Stage Denitrification Process by Simulation of GPS-X, J. of the Korean Society of Water and Wastewater, 18(1), pp. 37-48 [Korean Literature]
6 Hydronmantis inc., GPS-X technical reference, p XVIII (2001).
7 Choi, HN, Cho, EH, Kang, HG, Park, JH, Kang, SH(2015). A study on application eco-friendly follow-up process connected with livestock wastewater treatment plant using the upflow constructed wetland, J. of Korean Society of Water and Wastewater, 29(3), pp. 359-370 [Korea literature] [DOI http://dx.doi.org/10.11001/jksww.2015.29.3.359]   DOI
8 Im, JY, Gil, KI(2016). Effect of sewage flow on treatment efficiency of small wastewater treatment plant in rural community, J. of Wetlands Research, 18(3), pp. 267-274 [Korea literature] [DOI http://dx.doi.org/10.17663/JWR.2016.18.3.267]   DOI
9 Jeong, DH, Cho, YS, Ahn, KH, Kim, ES, Kim, CS, Chung, HM(2016). A study on characteristics of influent and effluent pollutants in public sewage treatment works combined with industrial wastewater and landfill lechate, J. of Korean Society of Water and Wastewater, 30(6), pp. 673-682 [Korea literature] [DOI http://dx.doi.org/10.11001/jksww.2016.30.6.673]   DOI