• 제목/요약/키워드: Ultrasound wave

검색결과 231건 처리시간 0.033초

The medium coupling effect on propagation of guided waves in engineering structures and human bone phantoms

  • Chen, Jiangang;Su, Zhongqing;Cheng, Li
    • Coupled systems mechanics
    • /
    • 제1권4호
    • /
    • pp.297-309
    • /
    • 2012
  • As a result of the medium coupling, propagation characteristics of ultrasonic waves guided by a multi-phase medium can be different from those in a homogeneous system. This phenomenon becomes prominent for a medium consisting of phases with considerably distinct material and physical properties (e.g., submerged structures or human bones covered with soft tissues). In this study, the coupling effect arising from both fluid and soft tissues on wave propagation in engineering structures and human bone phantoms, respectively, was explored and calibrated quantitatively, with a purpose of enhancing the precision of ultrasonic-wave-based non-destructive evaluation (NDE) and clinical quantitative ultrasound (QUS). Calibration results were used to rectify conventional NDE during evaluation of corrosion in a submerged aluminium plate, and QUS during prediction of simulated healing status of a mimicked bone fracture. The results demonstrated that with the coupling effect being appropriately taken into account, the precision of NDE and QUS could be improved.

Separate Reconstruction of Speed of Sound, Density, and Absorption Parameters in Ultrasound Inverse Scattering Tomography

  • Kwon, Sung-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • 제18권2E호
    • /
    • pp.18-23
    • /
    • 1999
  • This paper proposes a method of separately determining three intrinsic mechanical parameters of an unknown object in the framework of ultrasound inverse scattering tomography. Those parameters are the speed of sound, density, and absorption whose values are given as the solution of an inhomogeneous Helmholtz wave equation. The separate reconstruction method is mathematically formulated, the integral equations are discretized using the sinc basis functions, and the Newton-Raphson method is adopted as a numerical solver in a measurement configuration where the object is insonified by an incident plane wave over 360˚ and the scattered field is measured by detectors arranged in a rectangular fashion around it. Two distinct frequencies are used to separate each parameter of three Gaussian objects that are either located at the same position or separately from each other. Computer simulation results show that the separate reconstruction method is able to separately reconstruct the three mechanical parameters. The absorption parameter turns out to be a little difficult to reconstruct as compared with the other two parameters.

  • PDF

In-situ fatigue monitoring procedure using nonlinear ultrasonic surface waves considering the nonlinear effects in the measurement system

  • Dib, Gerges;Roy, Surajit;Ramuhalli, Pradeep;Chai, Jangbom
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.867-876
    • /
    • 2019
  • Second harmonic generation using nonlinear ultrasonic waves have been shown to be an early indicator of possible fatigue damage in nuclear power plant components. This technique relies on measuring amplitudes, making it highly susceptible to variations in transducer coupling and instrumentation. This paper proposes an experimental procedure for in-situ surface wave nonlinear ultrasound measurements on specimen with permanently mounted transducers under high cycle fatigue loading without interrupting the experiment. It allows continuous monitoring and minimizes variation due to transducer coupling. Moreover, relations describing the effects of the measurement system nonlinearity including the effects of the material transfer function on the measured nonlinearity parameter are derived. An in-situ high cycle fatigue test was conducted using two 304 stainless steel specimens with two different excitation frequencies. A comprehensive analysis of the nonlinear sources, which result in variations in the measured nonlinearity parameters, was performed and the effects of the system nonlinearities are explained and identified. In both specimens, monotonic trend was observed in nonlinear parameter when the value of fundamental amplitude was not changing.

초음파 치료 시 초음파 세기 변화에 따른 생리적 효과 연구 (A Study of Ultrasound Rehabilitation Therapy: Physiological Effects by Change of Ultrasound Intensity)

  • 김성민;이만표;최병철;최상혁;배하석;정회승;박성윤
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.40-45
    • /
    • 2008
  • Therapeutic ultrasound which is developed for rehabilitation therapy have already been used for healing joint contracture, synechia, acute and chronic inflammatory diseases. Medical devices for pain-relief and healing using therapeutic ultrasound are actively being developed. This study measured the change of PTT with the transmitted ultrasound through the human body to find out the increase of compliance of blood vessels. Measurement method of PTT in this study is employed as useful ways to acquire physiological information of patients in the clinical case in order to measure the change of mechanical characteristics of blood vessels. This study confirmed the PTT change of rehabilitation patients through the thermal effects of ultrasound by using PTT and also found that it is possible to increase PTT by adjusting the warm water and ultrasound. The increase of PTT means the decrease of the pulse wave velocity from the cardiovascular system to the peripheral arteries. The physiological effects occurred using the warm water and ultrasound.

전단파 탄성 초음파(Shear Wave Elastography)를 이용한 조기 간섬유화 예측 (Early Prediction of Liver Fibrosis Using Shear Wave Elastography)

  • 추서원;송종남;전철민;한재복
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1057-1065
    • /
    • 2023
  • 비침습적 간섬유화 진단은 만성 간질환 환자들에게 매우 중요한 사항이다. 많은 환자들에게 간조직검사를 시행할 수가 없기 때문에 의미 있는 간섬유화 정도를 조기에 예측함으로써 만성 간질환의 치료와 간세포암 및 간경변증으로 인한 합병증을 감소시킬 수 있다. 본 연구는 비침습적인 간섬유화 검사 방법 중 간초음파 소견과 함께 전단파 탄성 초음파를 이용하여 간섬유화의 정량적 측정과 간탄성도 수치와 연관성을 갖는 혈청학적 인자도 비교 분석하였다(p<0.05). 그 결과 정상 집단의 횡파탄성측정값은 4.55 ± 0.69 kPa였으며, 에코 패턴의 비정상 대조군은 8.27 ± 1.83 kPa로 B형 간염 보균 집단에서 전단파 탄성 초음파 측정값이 높게 나타났으며, 혈청학적 인자들 중 AST, ALT, GGT, PT가 SWE 범주에 따른 섬유화의 정도에 따라 통계학적으로 유의한 양의 연관성을 보였으나(p<0.05) ALP와 TB는 통계적으로 유의미한 차이를 나타내지 않았다(p=0.163, p=0.567). 반면에 Albumin과 PLT는 유의한 음의 연관성을 보였다(p<0.05). 임상적으로 간경변 증후가 없는 만성 B형 간염 환자들의 간섬유화 추적 관찰 및 반복 검사 시 간초음파와 전단파 탄성 초음파 검사를 통한 탄성도 값을 추가로 활용한다면 검사자 간 객관적 진단에 있어 도움이될 것이며, 일차적인 진료에 유용할 것으로 사료된다.

자동유방초음파 장비의 액와부 평가를 위한 초음파 패드 물질의 타당성 (Feasibility for Ultrasound Pad Material for the Evaluation Axillary Region of Automated Breast Ultrasound Equipment)

  • 서은희;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.231-240
    • /
    • 2018
  • Automated breast ultrasound (ABUS) equipment is a new innovative technique for 3D automatic breast scanning, but limited for the examination in the concave axillary region. The purpose of this study was to determine feasible candidate materials for the ultrasonic wave propagation media in ABUS, enabling the evaluation of the axillary region. Ultrasonography was performed using an ABUS system ($Invenia^{TM}ABUS$, GE, USA) on the ultrasound-specific phantom (UC-551M-0.5, ATS Laboratories, USA) covered by different candidate materials. The validity of feasible candidate materials was evaluated by image quality. Three independent radiological technologists, with more than 10 years of experience, visually assessed on the images. The inter-observer agreements according to the candidate materials were tested using Cronbach's alpha. Unenveloped solidified carrageenan can be a feasible material for the use of ABUS with excellent test reliability. Therefore, the coverage of the axillary region with carrageenan may be effective for ABUS which was originally developed for the convex anatomic structure as female breast.

Ultrasound imaging and guidance in the management of myofascial pain syndrome: a narrative review

  • Wei-Ting Wu;Ke-Vin Chang;Vincenzo Ricci;Levent Ozcakar
    • Journal of Yeungnam Medical Science
    • /
    • 제41권3호
    • /
    • pp.179-187
    • /
    • 2024
  • Myofascial pain syndrome (MPS) is a common musculoskeletal disorder characterized by muscle pain, tenderness, and trigger points. Ultrasonography has emerged as a key tool for diagnosing and treating MPS owing to its ability to provide precise, minimally invasive guidance. This review discusses the use of ultrasonography in various approaches to evaluate and manage MPS. Studies have shown that shear-wave sonoelastography can effectively assess muscle elasticity and offer insights into trapezius stiffness in patients with MPS. Ultrasound-guided interfascial hydrodissection, especially with visual feedback, has demonstrated effectiveness in treating trapezius MPS. Similarly, ultrasound-guided rhomboid interfascial plane blocks and perimysium dissection for posterior shoulder MPS have significantly reduced pain and improved quality of life. The combination of extracorporeal shockwave therapy with ultrasound-guided lidocaine injections has been particularly successful in reducing pain and stiffness in trapezius MPS. Research regarding various guided injections, including dry needling, interfascial plane blocks, and fascial hydrodissection, emphasizes the importance of ultrasonography for accuracy and safety. Additionally, ultrasound-guided delivery of local anesthetics and steroids to the quadratus lumborum muscle has shown lasting pain relief over a 6-month period. Overall, these findings highlight the pivotal role of ultrasonography in the assessment and treatment of MPS.

초음파를 이용한 두꺼운 복합재료의 보강섬유 굴곡 평가 (Nondestructive Evaluation of Fiber Waviness in Thick Composites by Ultrasonics)

  • 장필성;전흥재
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.258-263
    • /
    • 1999
  • In this study, the numerical and experimental investigations were conducted to understand ultrasonic wave propagation and to evaluate the degree of fiber waviness in thick composites nondestructively. The path, energy and traveling time of insonified wave were predicted by adopting the ray and plane wave theories. In the analysis, the composites were assumed to have continuous fiber with sinusoidal waviness in a matrix and were modeled as stacks of infinitesimally short length off-axis elements with varying fiber orientation along the length direction. From the experiments on the specially fabricated thick composite specimens with various degrees of uniform fiber waviness, the energy distributions of received wave were obtain for the various positions of transmitter. It was observed that the energy of wave was converged to the adjacent peaks of fiber waviness. The location where maximum energy of wave was detected from the experiments showed good agreement with the location obtained from theoretical predictions. Finally, the test procedure was Proposed to evaluate fiber waviness in thick composites by considering the energy of wave and relative distance between transmitter and receiver.

  • PDF

비집속 회분저주파를 이용한 Dunaliella salina 세포 파쇄 (Cell Disruption of Dunaliella salina using Batch Low Frequency Non-Focused Ultrasound)

  • 최준혁;김광호;박종락;정상화
    • 한국기계가공학회지
    • /
    • 제20권10호
    • /
    • pp.63-71
    • /
    • 2021
  • Using fossil fuels in existing industrial systems causes a variety of social problems. Recently, many studies have been conducted on bio-refineries, which aim to actively utilize biomass to reduce the use of fossil fuels and solve various social problems. Among them, research using microalgae as a third-generation biomass has attracted considerable attention. Microalgae use inorganic matter to produce organic matter, and cell destruction is necessary to extract useful organic materials from microalgae. The extracted organic materials are currently used in various industrial fields. Numerous cell-destruction methods exist. We have investigated cell disruption by sonication, especially its efficiency. Ultrasound is a sound wave with frequencies above 20 kHz, and destroys cells by sending high energy through a cavitation that occurs, according to the characteristics of the sound wave. The Dunaliella salina microalgae used in this study was cultured in a flat-type photobioreactor. Experiments were performed using a batch low-frequency processing device. Logistic model was applied to analyze the results of cell-destruction experiments using ultrasound. The proper conditions for the most efficient cell destruction were OD 1.4(microalgae concentration)), 54watt(output power) and 200mL(microalgae capacity).

The piezoelectricity of trabecular bone in cancellous bone wave propagation

  • Yoon, Young June;Chung, Jae Pil
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.104-107
    • /
    • 2021
  • The orientation of trabeculae and porosity determine the wave propagation in cancellous bone. Wave propagation, as well as charge density and piezoelectricity, stimulate bone remodeling. Also, Charged ions in the fluid affect wave propagation in cancellous bone. But the trabecular struts' piezoelectricity does not change the waveform of cancellous bone. However, the underlying mechanism is unknown yet why trabecula struts' piezoelectricity does not change wave propagation through cancellous bone. Thus, we derived the governing equation indicating that trabecular struts' piezoelectric properties show that those do not affect wave propagation in cancellous bone.