DOI QR코드

DOI QR Code

The medium coupling effect on propagation of guided waves in engineering structures and human bone phantoms

  • Chen, Jiangang (Department of Biomedical Engineering, Columbia University) ;
  • Su, Zhongqing (Department of Mechanical Engineering, The Hong Kong Polytechnic University) ;
  • Cheng, Li (Department of Mechanical Engineering, The Hong Kong Polytechnic University)
  • Received : 2012.09.17
  • Accepted : 2012.11.01
  • Published : 2012.12.25

Abstract

As a result of the medium coupling, propagation characteristics of ultrasonic waves guided by a multi-phase medium can be different from those in a homogeneous system. This phenomenon becomes prominent for a medium consisting of phases with considerably distinct material and physical properties (e.g., submerged structures or human bones covered with soft tissues). In this study, the coupling effect arising from both fluid and soft tissues on wave propagation in engineering structures and human bone phantoms, respectively, was explored and calibrated quantitatively, with a purpose of enhancing the precision of ultrasonic-wave-based non-destructive evaluation (NDE) and clinical quantitative ultrasound (QUS). Calibration results were used to rectify conventional NDE during evaluation of corrosion in a submerged aluminium plate, and QUS during prediction of simulated healing status of a mimicked bone fracture. The results demonstrated that with the coupling effect being appropriately taken into account, the precision of NDE and QUS could be improved.

Keywords

References

  1. Cheeke, J.D.N., Li, X. and Wang, Z. (1998), "Observation of flexural Lamb waves (A0 mode) on water-filled cylindrical shells", J. Acoust. Soc. Am., 104(6), 3678-3680. https://doi.org/10.1121/1.423951
  2. Cheeke, J.D.N., Shannon, K. and Wang, Z. (1999), "Loading effects on A0 Lamb-like waves in full and partially filled thin-walled tubes", Sensor. Actuat. B. - Chem., 59(2-3), 180-183. https://doi.org/10.1016/S0925-4005(99)00217-8
  3. Chen, J., Su, Z. and Cheng, L. (2010a), "Influence of soft tissues on propagation of ultrasonic Lamb waves in synthesised soft tissue-bone phantoms", IFMBE Proceedings, 31(6), 1315-1318.
  4. Chen, J., Su, Z. and Cheng, L. (2010b), "Identification of corrosion damage in submerged structures using fundamental anti-symmetric Lamb waves", Smart Mater. Struct., 19(1), 015004. https://doi.org/10.1088/0964-1726/19/1/015004
  5. Chen, J., Foiret, J., Minonzio, J.G., Talmant, M., Su, Z., Cheng, L. and Laugier, P. (2012a), "Measurement of guided mode wavenumbers in soft tissue-bone mimicking phantoms using ultrasonic axial transmission", Phys. Med. Biol., 57(10), 3025-3037. https://doi.org/10.1088/0031-9155/57/10/3025
  6. Chen, J., Su, Z. and Cheng, L. (2012b), "The effect of soft tissue coupling on propagation characteristics of ultrasonic waves: Calibration and application to quantitative ultrasound (QUS)", Ultrasonics, (In press).
  7. Lee, J., Na, W.B. and Kim, J.T. (2010), "Curvature effect on Guided Wave propagation in curved steel plates and hollow steel cylinders", Struct. Eng. Mech., 34(3), 395-398. https://doi.org/10.12989/sem.2010.34.3.395
  8. Lu, Y., Ye, L., Wang, D., Zhou, L.M. and Cheng, L. (2010), "Piezo-activated Guided Wave propagation and interaction with damage in tubular structures", Smart. Struct. Syst., 6(7), 835-849. https://doi.org/10.12989/sss.2010.6.7.835
  9. Moilanen, P., Nicholson, P.H.F., Kilappa, V., Cheng, S. and Timonen, J. (2006), "Measuring guided waves in long bones: Modeling and experiments in free and immersed plates", Ultrasound. Med. Biol., 32(5), 709-719. https://doi.org/10.1016/j.ultrasmedbio.2006.02.1402
  10. Moilanen, P., Talmant, M., Kilappa, V., Nicholson, P., Cheng, S. L., Timonen, J. and Laugier, P. (2008), "Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius", J. Acoust. Soc. Am., 124(4), 2364-2373. https://doi.org/10.1121/1.2973228
  11. Na, W.B. and Kundu, T. (2002), "Underwater pipeline inspection using guided waves", J. Press. Vess - t. Asme., 124(2), 196-200. https://doi.org/10.1115/1.1466456
  12. Protopappas, V.C., Fotiadis, D.I. and Malizos, K.N. (2006), "Guided ultrasound wave propagation in intact and healing long bones", Ultrasound. Med. Biol., 32(5), 693-708. https://doi.org/10.1016/j.ultrasmedbio.2006.02.001
  13. Su, Z. and Ye, L. (2009), Identification of damage using lamb waves: From fundamentals to applications, Springer-Verlag, Berlin Heidelberg.
  14. Yapura, C.L. and Kinra, V.K. (1995), "Guided waves in a fluid-solid bilayer", Wave Motion, 21(1), 35-46. https://doi.org/10.1016/0165-2125(94)00043-5
  15. Yu, J.G. and Ma, Z.J. (2012), "Guided viscoelastic Wave in circumferential direction of orthotropic cylindrical curved plates", Struct. Eng. Mech., 41(5), 605-615. https://doi.org/10.12989/sem.2012.41.5.605

Cited by

  1. Exploring and calibrating local curvature effect of cortical bone for quantitative ultrasound (QUS) vol.48, pp.4, 2013, https://doi.org/10.12989/sem.2013.48.4.501
  2. SH-wave propagation in a heterogeneous layer over an inhomogeneous isotropic elastic half-space vol.9, pp.2, 2015, https://doi.org/10.12989/eas.2015.9.2.305