• Title/Summary/Keyword: Ultrasound diagnostic system

Search Result 79, Processing Time 0.025 seconds

Development of a New Non-invasive Fetal Hypoxia Diagnosis System (새로운 비관혈적 태아 저산소증 진단 방법개발에 관한 연구)

  • Lee, Jeon;Lee, Kyoung-Joung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.11
    • /
    • pp.495-501
    • /
    • 2006
  • Diagnostics of unborn baby is mainly aimed at prediction and detection of occurrence of intrauterine hypoxia. Consequences resulting from fetal hypoxia appear in its heart activity. In this study, we have developed a new non-invasive system for fetal hypoxia diagnosis which provides systolic time interval(STI) parameters on the basis of analysis of electrical and mechanical heart activity together. For this we have worked on 1) the proper lead system for the acquisition of abdominal ECG, 2) the independent component analysis based signal processing and fetal ECG separation, 3) the development of a hardware which consists of an abdominal ECG amplifying module and an ultrasound module and 4) the detection of characteristic points of FECG and Doppler signal and the extraction of diagnostic parameters. The developed system was evaluated by the clinical experiments in which 33 subjects were participated. The acquired STI by the system were distributed within the ranges from the well-established invasive results of other researchers. From this, we can conclude that the developed non-invasive fetal hypoxia diagnosis system is useful.

Scoring System to Predict Malignancy for MRI-Detected Lesions in Breast Cancer Patients: Diagnostic Performance and Effect on Second-Look Ultrasonography (유방암 환자의 MRI에서 발견된 병변의 악성 예측을 위한 점수체계: 진단적 능력과 이차 초음파 결정에 미치는 영향)

  • Young Geol Kwon;Ah Young Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.379-394
    • /
    • 2020
  • Purpose To design a scoring system to predict malignancy of additional MRI-detected lesions in breast cancer patients. Materials and Methods Eighty-six lesions (64 benign and 22 malignant) detected on preoperative MRI of 68 breast cancer patients were retrospectively included. The clinico-radiologic features were correlated with the histopathologic results using the Student's t-test, Fisher's exact test, and logistic regression analysis. The scoring system was designed based on the significant predictive features of malignancy, and its diagnostic performance was compared with that of the Breast Imaging-Reporting and Data System (BI-RADS) category. Results Lesion size ≥ 8 mm (p < 0.001), location in the same quadrant as the primary cancer (p = 0.005), delayed plateau kinetics (p = 0.010), T2 isointense (p = 0.034) and hypointense (p = 0.024) signals, and irregular mass shape (p = 0.028) were associated with malignancy. In comparison with the BI-RADS category, the scoring system based on these features with suspicious non-mass internal enhancement increased the diagnostic performance (area under the receiver operating characteristic curve: 0.918 vs. 0.727) and detected three false-negative cases. With this scoring system, 22 second-look ultrasound examinations (22/66, 33.3%) could have been avoided. Conclusion The scoring system based on the lesion size, location relative to the primary cancer, delayed kinetic features, T2 signal intensity, mass shape, and non-mass internal enhancement can provide a more accurate approach to evaluate MRI-detected lesions in breast cancer patients.

A Prospective Study on the Value of Ultrasound Microflow Assessment to Distinguish Malignant from Benign Solid Breast Masses: Association between Ultrasound Parameters and Histologic Microvessel Densities

  • Ah Young Park;Myoungae Kwon;Ok Hee Woo;Kyu Ran Cho;Eun Kyung Park;Sang Hoon Cha;Sung Eun Song;Ju-Han Lee;JaeHyung Cha;Gil Soo Son;Bo Kyoung Seo
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.759-772
    • /
    • 2019
  • Objective: To investigate the value of ultrasound (US) microflow assessment in distinguishing malignant from benign solid breast masses as well as the association between US parameters and histologic microvessel density (MVD). Materials and Methods: Ninety-eight breast masses (57 benign and 41 malignant) were examined using Superb Microvascular Imaging (SMI) and contrast-enhanced US (CEUS) before biopsy. Two radiologists evaluated the quantitative and qualitative vascular parameters on SMI (vascular index, morphology, distribution, and penetration) and CEUS (time-intensity curve analysis and enhancement characteristics). US parameters were compared between benign and malignant masses and the diagnostic performance was compared between SMI and CEUS. Subgroup analysis was performed according to lesion size. The effect of vascular parameters on downgrading Breast Imaging Reporting and Data System (BI-RADS) category 4A masses was evaluated. The association between histologic MVD and US parameters was analyzed. Results: Malignant masses were associated with a higher vascular index (15.1 ± 7.3 vs. 5.9 ± 5.6), complex vessel morphology (82.9% vs. 42.1%), central vascularity (95.1% vs. 59.6%), penetrating vessels (80.5% vs. 31.6%) on SMI (all, p < 0.001), as well as higher peak intensity (37.1 ± 25.7 vs. 17.0 ± 15.8, p < 0.001), slope (10.6 ± 11.2 vs. 3.9 ± 4.2, p = 0.001), area (1035.7 ± 726.9 vs. 458.2 ± 410.2, p < 0.001), hyperenhancement (95.1% vs. 70.2%, p = 0.005), centripetal enhancement (70.7% vs. 45.6%, p = 0.023), penetrating vessels (65.9% vs. 22.8%, p < 0.001), and perfusion defects (31.7% vs. 3.5%, p < 0.001) on CEUS (p ≤ 0.023). The areas under the receiver operating characteristic curve (AUCs) of SMI and CEUS were 0.853 and 0.841, respectively (p = 0.803). In 19 masses measuring < 10 mm, central vascularity on SMI was associated with malignancy (100% vs. 38.5%, p = 0.018). Considering all benign SMI parameters on the BI-RADS assessment, unnecessary biopsies could be avoided in 12 category 4A masses with improved AUCs (0.500 vs. 0.605, p < 0.001). US vascular parameters associated with malignancy showed higher MVD (p ≤ 0.016). MVD was higher in malignant masses than in benign masses, and malignant masses negative for estrogen receptor or positive for Ki67 had higher MVD (p < 0.05). Conclusion: US microflow assessment using SMI and CEUS is valuable in distinguishing malignant from benign solid breast masses, and US vascular parameters are associated with histologic MVD.

A case series on nonpuerperal mastitis and breast abscess (비수유기 유선염 및 유방농양 환자 증례 보고)

  • Lee, Jong-Deok;Ryu, Sung-Won;Choi, Chang-Min
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.19 no.2
    • /
    • pp.295-304
    • /
    • 2006
  • Inflammatory conditions of the breast are uncommon and may be encountered in the puerperal and nonpuerperal setting. Nonpuerperal mastitis is less common and usually presents with inflammation and chronic abscess formation in the periareolar and peripheral region. These abscess have a high rate of recurrence and are often associated with an underlying disease state, such as diabetes, steroid treatment, trauma or other kinds of a deficient immune system. The diagnosis is suggested by the history of sudden onset and the presense of swelling, tenderness, heat, erythema, and in the case of abscess, fluctuation. Ultrasound can also be useful. Treatment consists of antibiotic administration or incision and drainage of the abscess and, in cases of retroareolar abscess, resection of entire underlying duct system. Recently, we have gotten good result from treating two cases of nonpuerperal mastitis and breast abscess which had treatment of antibiotics and drainage three times but recurred. After taking gamijipaesan(加味芷貝散) and acupuncture treatment, they have recovered and haven't recurred in 8 months. So it proves that herb medication and acupuncture are effective on nonpuerperal chronic mastitis and breast abscess.

  • PDF

FPGA-Based Low-Power and Low-Cost Portable Beamformer Design (FPGA 기반 저전력 및 저비용 휴대용 빔포머 설계)

  • Jeong, GabJoong;Park, CheolYoung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • In this paper, we develop a beamforming front end platform with pipeline circuit configuration method that can apply various clinical diagnostic applications of ultrasound image technology. Hardware design targets compression applications as well as scalable applications where power, integration levels and replication possibilities are important. Firmware design was implemented to achieve optimal FPGA parallel processing level by constructing new IP and system-oriented design environment to accelerate design productivity with maximum productivity improvement using Vivado HLS tool, which is a next generation high level synthesis tool. Former supports the high-speed management function of scan data that can create an image area arbitrarily and can be appropriately corrected and supplemented when reconfiguring or changing system specifications in the future.

The Association Between Masticatory Function Assessment and Masseter Muscle Thickness in the Elderly

  • Jung, Hyo-Jung;Min, Yong-Guang;Kim, Hyo-Jung;Lee, Joo-Young;Choi, Jong-Hoon;Kim, Baek-Il;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.45 no.3
    • /
    • pp.49-55
    • /
    • 2020
  • Purpose: This study investigated the association between the objective indicator of masticatory function assessment and the masseter muscle thickness (MMT) using ultrasound imaging. Methods: A total of 99 subjects (males: 24, females: 75, mean age: 76) were analyzed. The maximum bite force (MBF) was measured with a pressure-sensitive sheet and an image scanner. The mixing ability index (MAI) was calculated by image analysis after asking the subjects to chew a wax specimen. The MMT during rest and clenching were obtained with a diagnostic ultrasound system, and the difference in MMT during rest and MMT during clenching was defined as the difference in masseter muscle thickness (DMMT). Multiple regression analysis was performed to determine the independent variables affecting MBF and MAI. Results: The MBF showed correlation with the number of remaining teeth (β=0.346, p=0.002) and DMMT (β=0.251, p=0.011). The MAI correlated with only the number of remaining teeth (β=0.476, p<0.001). Conclusions: The DMMT reflects the state of masseter muscle contraction, and can be used as a predictor as well as the number of teeth when assessing masticatory function.

Diagnosing Hepatocellular Carcinoma Using Sonazoid Contrast-Enhanced Ultrasonography: 2023 Guidelines From the Korean Society of Radiology and the Korean Society of Abdominal Radiology

  • Woo Kyoung Jeong;Hyo-Jin Kang;Sang Hyun Choi;Mi-Suk Park;Mi Hye Yu;Bohyun Kim;Myung-Won You;Sanghyeok Lim;Young Seo Cho;Min Woo Lee;Jeong Ah Hwang;Jae Young Lee;Jung Hoon Kim;Ijin Joo;Jae Seok Bae;So Yeon Kim;Yong Eun Chung;Dong Hwan Kim;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.6
    • /
    • pp.482-497
    • /
    • 2023
  • Sonazoid, a second-generation ultrasound contrast agent, was introduced for the diagnosis of hepatic nodules. To clarify the issues with Sonazoid contrast-enhanced ultrasonography for the diagnosis of hepatocellular carcinoma (HCC), the Korean Society of Radiology and Korean Society of Abdominal Radiology collaborated on the guidelines. The guidelines are de novo, evidence-based, and selected using an electronic voting system for consensus. These include imaging protocols, diagnostic criteria for HCC, diagnostic value for lesions that are inconclusive on other imaging results, differentiation from non-HCC malignancies, surveillance of HCC, and treatment response after locoregional and systemic treatment for HCC.

Development of Healthcare Data Quality Control Algorithm Using Interactive Decision Tree: Focusing on Hypertension in Diabetes Mellitus Patients (대화식 의사결정나무를 이용한 보건의료 데이터 질 관리 알고리즘 개발: 당뇨환자의 고혈압 동반을 중심으로)

  • Hwang, Kyu-Yeon;Lee, Eun-Sook;Kim, Go-Won;Hong, Seong-Ok;Park, Jung-Sun;Kwak, Mi-Sook;Lee, Ye-Jin;Lim, Chae-Hyeok;Park, Tae-Hyun;Park, Jong-Ho;Kang, Sung-Hong
    • The Korean Journal of Health Service Management
    • /
    • v.10 no.3
    • /
    • pp.63-74
    • /
    • 2016
  • Objectives : There is a need to develop a data quality management algorithm to improve the quality of healthcare data using a data quality management system. In this study, we developed a data quality control algorithms associated with diseases related to hypertension in patients with diabetes mellitus. Methods : To make a data quality algorithm, we extracted the 2011 and 2012 discharge damage survey data from diabetes mellitus patients. Derived variables were created using the primary diagnosis, diagnostic unit, primary surgery and treatment, minor surgery and treatment items. Results : Significant factors in diabetes mellitus patients with hypertension were sex, age, ischemic heart disease, and diagnostic ultrasound of the heart. Depending on the decision tree results, we found four groups with extreme values for diabetes accompanying hypertension patients. Conclusions : There is a need to check the actual data contained in the Outlier (extreme value) groups to improve the quality of the data.

Comparative evaluation of ultrasonography with clinical respiratory score in diagnosis and prognosis of respiratory diseases in weaned dairy buffalo and cattle calves

  • Hussein, Hussein Awad;Binici, Cagri;Staufenbiel, Rudolf
    • Journal of Animal Science and Technology
    • /
    • v.60 no.12
    • /
    • pp.29.1-29.11
    • /
    • 2018
  • Background: Respiratory troubles have economic impacts in countries where livestock industry is an important segment of the agricultural sector, as well as these problems may cause significant economic losses for bovine producers. Various practical methods are used to assess diseases that affect the bovine respiratory system. Ultrasonography is a noninvasive tool that has been used frequently in diagnosis of various animal diseases. The present study was designed to establish whether thoracic ultrasonography is a diagnostic tool for detection of respiratory troubles in weaned buffalo and cattle calves, as well as to assess its prognostic value in comparison with clinical respiratory scores. Thirty five (15 buffalo and 20 cattle) calves were included. Twelve (6 buffalo and 6 cattle) clinically healthy calves were enrolled as controls. Results: Based on physical examinations, clinical respiratory scores (CRS), ultrasound lung scores (ULS) and postmortem findings, animals were classified into 4 groups as pulmonary emphysema (n = 8), interstitial pulmonary syndrome (n = 7), bronchopneumonia (n = 12), and pleurisy (n = 8). The mean values of CRS and ULS were significantly higher in diseased calves (P < 0.01). In calves with pulmonary emphysema and interstitial syndrome, thoracic ultrasonography revealed numerous comet-tail artifacts, which varied in numbers and imaging features. Furthermore, variable degrees of pulmonary consolidation with alveolograms and bronchograms were noticed in bronchopneumonic calves. In addition, thick irregular or fragmented pleura with pleural effusions and fibrin shreds were imaged in calves with pleurisy. A weak correlation was calculated between CRS and ULS (r = 0.55, P < 0.01). Hematologically, the counts of white blood cells, activities of aspartate aminotransferase and partial tensions of carbon dioxide were significantly increased in all diseased groups. Serum concentrations of total globulins were higher in claves with bronchopneumonia (P < 0.05). The partial tension of oxygen was decreased in all diseased calves (P < 0.05). Conclusions: Thoracic ultrasonography is a diagnostic tool for various lung troubles and assessment the grade and severity of pulmonary diseases, as well as it can be used as a follow-up tool for evaluating the prognosis of respiratory troubles and monitoring the efficacy of therapies.

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.