• 제목/요약/키워드: Ultrasound Wave

검색결과 228건 처리시간 0.024초

Simulation of Excitation and Propagation of Pico-Second Ultrasound

  • Yang, Seungyong;Kim, Nohyu
    • 비파괴검사학회지
    • /
    • 제34권6호
    • /
    • pp.457-466
    • /
    • 2014
  • This paper presents an analytic and numerical simulation of the generation and propagation of pico-second ultrasound with nano-scale wavelength, enabling the production of bulk waves in thin films. An analytic model of laser-matter interaction and elasto-dynamic wave propagation is introduced to calculate the elastic strain pulse in microstructures. The model includes the laser-pulse absorption on the material surface, heat transfer from a photon to the elastic energy of a phonon, and acoustic wave propagation to formulate the governing equations of ultra-short ultrasound. The excitation and propagation of acoustic pulses produced by ultra-short laser pulses are numerically simulated for an aluminum substrate using the finite-difference method and compared with the analytical solution. Furthermore, Fourier analysis was performed to investigate the frequency spectrum of the simulated elastic wave pulse. It is concluded that a pico-second bulk wave with a very high frequency of up to hundreds of gigahertz is successfully generated in metals using a 100-fs laser pulse and that it can be propagated in the direction of thickness for thickness less than 100 nm.

Theoretical observation of waves in cancellous bone

  • Yoon, Young-June;Chung, Jae-Pil
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.419-424
    • /
    • 2020
  • Poroelasticity theory has been widely used for detecting cancellous bone deterioration because of the safe use for humans. The tortuosity itself is an important indicator for ultrasound detection for bone diseases. The transport properties of cancellous bone are also important in bone mechanotransduction. In this paper, two important factors, the wave velocity and attenuation are examined for permeability (or tortuosity). The theoretical calculation for the relationship between the wave velocity (and attenuation) and permeability (or tortuosity) for cancellous bone is shown in this study. It is found that the wave along the solid phase (trabecular struts) is influenced not by tortuosity, but the wave along the fluid wave (bone fluid phase) is affected by tortuosity significantly. However, the attenuation is different that the attenuation of a fast wave has less influence than that of a slow wave because the slow wave is observed by the relative motion between the solid and fluid phases.

후방복사된 초음파를 이용한 터빈 블레이드 재료의 부식 열화특성 평가 (Evaluation of Corrosion Degradation Characteristics of Turbine Blade Material Using Backward Radiated Ultrasound)

  • 송성진;김영환;배동호;정민호;권성덕
    • 대한기계학회논문집A
    • /
    • 제26권11호
    • /
    • pp.2322-2327
    • /
    • 2002
  • The corrosion degradation characteristics of the 12Cr alloy steel, which is widely used in fossil power plants as a turbine blade material, are evaluated nondestructively by use of the backward radiated Rayleigh surface wave. In order to evaluate corrosion degradation characteristics, we constructed automated system for the backward radiation, and the frequency dependency of the Rayleigh surface wave is investigated indirectly by measuring the angular dependency of the backward radiation of the incident ultrasonic wave in the specimens. The velocity of the surface wave decrease as the increase of the aging time in the backward radiation profile, which seems to result from the increase of the effective degrading layer thickness. And, amplitude of the surface wave increase as the aging time, which seems to result from the increase of the intergranular corrosion. The result observed in this study demonstrates high potential of the backward radiated ultrasound as a tool for the nondestructive evaluation of the corrosion degradation characteristics of the aged materials.

선형 파면을 이용한 새로운 합성구경 기법 (A New Synthetic Aperture Technique Using Linear Wave Fronts)

  • 장진호;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권4호
    • /
    • pp.321-330
    • /
    • 2001
  • In this paper, we propose a new synthetic aperture focusing scheme for improving the lateral resolution which is one of the most important factors determining the quality of ultrasound imaging. The proposed scheme enables full round-trip dynamic focusing with approximately limited property. This properties are obtained through transmitting plane waves of which the traveling angle varies with the receive subaperture position, as opposed to stepping the spherical wave source across an array in other synthetic aperture focusing schemes, and employing dynamic focusing in receive. In this paper, the properties of the proposed scheme is analyzed in which a hypothetical infinite line source is used to transmit the plane waves and verified through computer simulation results. Also, we show that the proposed scheme is realizable with an array transducer with a finite aperture size. In summary, it is shown through comparison between the field contours of the proposed scheme and the conventional scheme that the proposed scheme can improve greatly the lateral resolution of ultrasound imaging.

  • PDF

초음파 연조직 팬텀에서 횡탄성의 측정 (Measurement of the Shear Modulus of an Ultrasound Tissue Phantom)

  • 박정만;최승민;권성재;정목근
    • 한국음향학회지
    • /
    • 제31권6호
    • /
    • pp.399-409
    • /
    • 2012
  • 본 논문에서는 초음파 연조직 팬텀에서 음향 복사력을 이용하여 횡탄성(shear modulus)을 측정하는 방법을 제안하였다. 이 방법은 집속 초음파 빔의 초점에서 음향 복사력에 의해 발생하는 변위의 상승시간에 기초하여 횡탄성을 정량적으로 산정한다. 제안한 방법의 타당성을 확인하기 위하여 횡파 전파법으로 측정한 횡파의 속도 및 횡탄성값 결과와 비교하였다. 횡파 전파법은 제한회절 송신음장에 의해 팬텀에서 발생하여 전파하는 횡파의 속도를 측정하여 횡탄성값을 계산하고, 이 값으로 교정된 데이터 획득 시스템에서 제안한 방법으로 측정한 횡탄성값을 횡파 전파법으로 측정한 값과 비교하여, 제안한 횡탄성 측정법의 유용성을 확인하였다. 두 방법 간의 상대오차는 횡파 속도는 4%로, 횡탄성값은 9% 이하로 계산되었다.

초음파 서모그라피를 이용한 빠른 PCB 결함 검출 (Fast Defect Detection of PCB using Ultrasound Thermography)

  • 조재완;서용칠;정승호;김승호;정현규
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권2호
    • /
    • pp.68-71
    • /
    • 2006
  • Active thermography has been used for several years in the field of remote non-destructive testing. It provides thermal images for remote detection and imaging of damages. Also, it is based on propagation and reflection of thermal waves which are launched from the surface into the inspected component by absorption of modulated radiation. For energy deposition, it use external heat sources (e.g., halogen lamp or convective heating) or internal heat generation (e.g., microwaves, eddy current, or elastic wave). Among the external heat sources, the ultrasound is generally used for energy deposition because of defect selective heating up. The heat source generating a thermal wave is provided by the defect itself due to the attenuation of amplitude modulated ultrasound. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected ultrasonic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by thermal infrared camera. This way ultrasound thermography(UT) allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. In this paper the applicability of UT for fast defect detection is described. Examples are presented showing the detection of defects in PCB material. Measurements are performed on various kinds of typical defects in PCB materials (both Cu metal and non-metal epoxy). The obtained thermal image reveals area of defect in row of thick epoxy material and PCB.

Exploring and calibrating local curvature effect of cortical bone for quantitative ultrasound (QUS)

  • Chen, Jiangang;Su, Zhongqing;Cheng, Li;Ta, De-An
    • Structural Engineering and Mechanics
    • /
    • 제48권4호
    • /
    • pp.501-518
    • /
    • 2013
  • Apart from thinning of cortical layers, the local bone curvature, varying along bone periphery, modulates ultrasound waves as well, which is however often underestimated or overlooked in clinical quantitative ultrasound (QUS). A dedicated three-dimensional finite element modelling technique for cortical bones was established, for quantitatively exploring and calibrating the effect of local curvature of cortical bone on ultrasound. Using a correlation-based mode extraction technique, high-velocity group (HVG) and low-velocity group (LVG) wave modes in a human radius were examined. Experimental verification using acrylic cylinders and in vitro testing using a porcine femur were accomplished. Results coherently unravelled the cortical curvature exerts evident influence on bone-guided ultrasound when RoC/${\lambda}$ <1 for HVG mode and RoC/${\lambda}$ <2 for LVG mode (RoC/${\lambda}$: the ratio of local bone curvature radius to wavelength); the sensitivity of LVG mode to bone curvature is higher than HVG mode. It has also been demonstrated the local group velocity of an HVG or LVG mode at a particular skeletal site is equivalent to the velocity when propagating in a uniform cylinder having an outer radius identical to the radius of curvature at that site. This study provides a rule of thumb to compensate for the effect of bone curvature in QUS.

초음파 방사힘을 이용한 손바닥의 촉각 인식과 응용 (Haptic recognition of the palm using ultrasound radiation force and its application)

  • 김선애;김태양;이열음;이수연;정목근;권성재
    • 한국음향학회지
    • /
    • 제38권4호
    • /
    • pp.467-475
    • /
    • 2019
  • 고출력의 초음파는 매질을 진행하면 음향 흐름과 음향 방사힘을 만들어낸다. 공기를 매질로 하는 3차원 공간상에 음향 방사힘을 발생시키면 입체적인 촉감을 형성할 수 있으므로 공간적인 정보를 직접 피부에 촉각으로 전달할 수 있다. 본 논문은 40 kHz의 작은 초음파 송신자 154개를 묶어 오목한 형태로 배열시켜서 초음파를 송신하여 집속초점에서 음향 방사힘을 발생시켰다. 초음파 음장의 초점의 근처에서 음향 방사힘에 의한 촉각을 확인하였다. 촉각 감도를 올리기 위하여 송신 초음파를 60 Hz의 구형파로 진폭 변조를 하였다. 초음파 촉각의 응용으로 음향 방사힘이 형성되는 허공에 촉각이 감지되는 영역을 형성시켜서, 손의 위치를 지정하는 지시자로 사용하였다. 촉각이 감지되는 초점위치에 있는 손의 모양을 영상 입력으로 받아서 손가락의 개수를 기계에 피드백하는 시스템을 구현함으로써 초음파를 이용한 촉각의 유용성을 확인하였다.

대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석 (Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model)

  • 최호선
    • 정보학연구
    • /
    • 제8권1호
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

  • Kim, Do-Youn;Cho, Youn-Ho;Lee, Joon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제42권5호
    • /
    • pp.546-551
    • /
    • 2010
  • The objective of this research is to estimate the crack location and size of a carbon steel pipe by using a laser ultrasound guided wave for the wall thinning evaluation of an elbow. The wall thinning of the carbon steel pipe is one of the most serious problems in nuclear power plants, especially the wall thinning of the carbon steel elbow caused by Flow-Accelerated Corrosion (FAC). Therefore, a non-destructive inspection method of elbow is essential for the nuclear power plants to operate safely. The specimens used in this study were carbon steel elbows, which represented the main elements of real nuclear power plants. The shape of the wall thinning was an oval with a width of 120mm, a length of 80mm, and a depth of 5mm. The L(0,1) and L(0,2) modes variation of the ultrasound guided wave signal is obtained from the response of the laser generation/air-coupled detection ultrasonic hybrid system represent the characteristics of the defect. The trends of these characteristics and signal processing were used to estimate the size and location of wall thinning.