• Title/Summary/Keyword: Ultrasonic scale

검색결과 140건 처리시간 0.029초

늑골 골절 환자에서 초음파 유도하 흉추 주위 공간(TPVS) 소염약침 치료를 시행한 한방치료군과 촉지하 소염약침 치료를 시행한 한방치료군의 통증 및 치료만족도 비교 연구: 후향적 연구 (A Comparative Study on the Pain and Treatment Satisfaction between Korean Medical Treatment Combined with Ultrasound Guided Soyeom Pharmacopuncture Therapy in Thoracic Paravertebral Space and Non-Guided Soyeom Pharmacopuncture Therapy on Patients with Ribs Fracture: A Retrospective Study)

  • 김연희;오태영;이은정;오민석
    • 한방재활의학과학회지
    • /
    • 제29권3호
    • /
    • pp.103-112
    • /
    • 2019
  • Objectives The purpose of this study is to investigate pain reduction and treatment satisfaction of patients with rib fracrture treated with Soyeom pharmacopuncture therapy under ultrasonic guided - thoracic paravertebral space (TPVS), and also compare to the patients with non-guided pharmacoacupuncture. Methods We studied medical records of 6 patients hospitalized with rib fractures were analyzed retrospectively at department of Korean Medicine Rehabilitation from March 1, 2019 to May 31, 2019, The 3 patients had performed the treatment of Soyeom pharmacopuncture therapy on TPVS under ultrasonic guidance with Korean Medicine treatment (such as herbal medicine, acupuncture, moxabustion, etc) and the other 3 patients had performed the treatment of Soyeom pharmacopuncture therapy on TPVS through non-guided. We used numeric rating scale to assess improvements in pain and the five-point likert scale was used to assess treatment satisfaction. Statistical analysis was carried out using the IBM SPSS Statistics 24 program. Results The purpose of this study is to investigate pain reduction and treatment satisfaction of patients with rib fracrture treated with Soyeom pharmacopuncture therapy under ultrasonic guided - TPVS, and also compare to the patients with non-guided pharmacoacupuncture. Conclusions After analyzing 6 studies, we could imply that the treatment of Soyeom pharmacopuncture therapy on TPVS under ultrasonic guidance could be more effective on pain reduction and improvement of treatment satisfaction with rib fracture compared to those who were treated with non-guided pharmacoacupuncture.

차량의 변속기 오일레벨 측정을 위한 FPGA 기반 초음파 레벨 측정기 개발 (A FPGA-based Development of Ultrasonic Level Meter for Measuring Oil Levels of Vehicle Transmissions)

  • 강문호;박윤창
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5427-5433
    • /
    • 2012
  • 본 논문에서는 자동차 변속기 오일레벨을 정확하고 손쉽게 측정할 수 있는 초음파 오일레벨 측정기를 개발하고 실험을 통하여 유용성을 보였다. 초음파 프로브 구동 펄스 생성과 오일레벨 연산을 비롯한 모든 디지털 신호 처리가 하나의 FPGA에 의해서 이루어지도록 하여 측정기의 단순화와 고성능화를 이루었고, 모든 프로그램을 FPGA 프로젝트 IDE상에서 제작하여 측정기 개발 시간을 줄일 수 있었다. 또한, 저-레벨의 초음파 에코 신호를 처리하기 위한 송수신 스위치회로, 다단 능동 필터회로 및 포락선 검출회로 등을 설계하였고, 실험을 통하여 설계된 측정기가 약 1mm 이내의 측정 정확도를 가짐을 확인하였다.

초음파 검사에 의한 수중의 살균처리 (Disinfection of Water by Ultrasonic Irradiation)

  • 손종렬;유병성
    • 환경위생공학
    • /
    • 제14권1호
    • /
    • pp.54-61
    • /
    • 1999
  • The industrial techniques of ultrasound have been used in the various fields, such as cleaning, medical surgery, emulsification, cell disruption etc. Especially the application of cell disruption was interested in the field of disinfection process in water by ultrasonic irradiation. It has been recognized that the ultrasounds are irradiated in aqueous solution, cavitation bubbles are generated and shock waves of high temperature and pressure are emitted as the bubbles are developed and finally broken, which function as a energy source to promote reaction efficiencies of various kinds of chemical reactions such as disinfection reaction in water. Therefore, this study was performed to apply the ultrasound for the disinfection method of infected drinking raw water and to discuss the limiting factors such as pH, sample volume and reaction temperature influenced on the removal efficiency of E. coli from experimental analysis of the results obtained in bench-scale plant. For the experiments to measure the influence of reaction parameters in the ultrasonic disinfection process, escalated reactivity of aqueous solutions was excellent when pH in aqueous solution was low, and sample volume was small. On the contrary, the reactivity of disinfection became elevated when reaction temperature was high. It was found that the rate constant of disinfection reaction was applied by Chick's law, reaction kinetics of Chick's law was irreversible and pseudo-first order at all the tested conditions.As a conclusion it appeared that the technology using ultrasonic irradiation can be applied to the treatment of disinfection in infected water which are difficult to be treated by conventional methods.

  • PDF

Development of a Ultrasonic System for Nano-Surface Reformation Process

  • Kim, Hyunse;Lim, Euisu;Park, Jong-Kweon
    • 한국생산제조학회지
    • /
    • 제26권4호
    • /
    • pp.365-370
    • /
    • 2017
  • In this article, a 20 kHz Titanium (Ti) ultrasonic waveguide system for a nano-surface reformation process was designed and fabricated. First, finite element analysis using ANSYS software was performed to find the optimal dimensions. The obtained anti-resonance frequency for the Ti transducer with the piezoelectric device was 20.0 kHz, which value agreed well with the experiment result of 20.1 kHz (0.5% error). To test the system, chromium molybdenum steel (SCM) 435 was chosen as a test-piece. The result proved that the reformed depth was $36{\mu}m$. In addition, hardness was measured before and after the process. The value was changed from 14 HRC to 21 HRC, which is 50% increasing rate. Finally, the friction coefficient test result showed that the surface coefficient was reduced from 0.14 to 0.10 (28.6% reduction). Based on the results, the Ti ultrasonic equipment is regarded as a useful device for nano-scale surface reformation.

나노표면개질 용 초음파 진동자 설계 및 제작 (Design and Manufacturing of an Ultrasonic Waveguide for Nano-surface Treatment)

  • 김현세;이양래;임의수
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1115-1119
    • /
    • 2014
  • In this article, a 20 kHz ultrasonic waveguide for nano-surface treatment was designed and manufactured. When designing the system, finite element analysis with ANSYS software was performed to find optimal dimensions of the waveguide, which can raise energy efficiency. Consequently an anti-resonance frequency of an Al waveguide with a piezoelectric actuator was 20 kHz, which predicted the experimentally obtained value of 18 kHz well. For the assessment of the performance, Steel Use Stainless (SUS) 304 and chromium molybdenum steel (SCM) 435 specimens were tested. Cross-sectional microscopies of SUS304 were taken and they showed that the treated thickness was $30{\mu}m$. Additionally, hardness tests of SCM435 were done and the hardness before the process was 14.0 Rockwell Hardness-C scale (HRC) and after the process was 20.5 HRC, respectively, which means 46% increase. Considering these results, the developed ultrasonic system is thought to be effective in the nano-surface treatment process.

Micro-Pressing 방법과 Dicing 방법에 의해 제조된 PZT Ultrasonic Transducer Array의 특성 (Properties of PZT Ultrasonic Transducer Array Fabricated by Micro-Pressing and Dicing method)

  • 박준식;홍성제;조진우;박순섭;한진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2248-2250
    • /
    • 2000
  • We investigated properties of PZT composite for medical ultrasonic transducer array (briefly UTA) for medicine applications fabricated by micro pressing and dicing method. Dicing method was the fabrication process of conventional ultrasonic transducer array by dicing sintered PZT sheet. Micro pressing method was the proposed process using pressing PZT green sheet by PMMA micro mold from LIGA process. Microstructures, electrical and electro -mechanical properties of fabricated UTAs of two cases were analyzed. Thickness mode electro-mechanical coupling coefficient of two cases have same values of 51%. Sintered PZT Microstructures of them showed dense and uniform. Micro pressing method was very mass productive process because of using batch type LIGA process. From results, we found micro pressing method was more competitive than dicing method for UTA fabrication. For further study, uniformity of microstructures and electro-mechanical properties of large scale, and fabrication processes of Ni plating and PMMA molding should be improved and investigated.

  • PDF

Ring-Type Rotary Ultrasonic Motor Using Lead-free Ceramics

  • Hong, Chang-Hyo;Han, Hyoung-Su;Lee, Jae-Shin;Wang, Ke;Yao, Fang-Zhou;Li, Jing-Feng;Gwon, Jung-Ho;Quyet, Nguyen Van;Jung, Jin-Kyung;Jo, Wook
    • 센서학회지
    • /
    • 제24권4호
    • /
    • pp.228-231
    • /
    • 2015
  • Ultrasonic motors provide high torques and quick responses compared to their magnetic counterparts; therefore, they are widely used in small-scale applications such as mobile phones, microrobots, and auto-focusing modules in digital cameras. To determine the feasibility of lead-free piezoceramics for ultrasonic motor applications, we fabricated a ring-type piezoceramic with a KNN-based lead-free piezoceramic (referred to as CZ5), intended for use in an auto-focusing module of a digital camera. The vibration of the lead-free stator was observed at 45.1 kHz. It is noteworthy that the fully assembled lead-free ultrasonic motor exhibited a revolution speed of 5-7 rpm, even though impedance matching with neighboring components was not considered. This result suggests that the tested KNN-based piezoceramic has great potential for use in ultrasonic motor applications, requiring minimal modifications to existing lead-based systems.

The Effect of Ozonized Water Irrigation in the Circuits of Professional Ultrasonic Scalers for Causal Therapy of Stage I Periodontitis: A Randomized Clinical Study

  • Simone Marconcini;Enrica Giammarinaro;Giacomo Oldoini;Annamaria Genovesi
    • 치위생과학회지
    • /
    • 제23권1호
    • /
    • pp.13-19
    • /
    • 2023
  • Background: Periodontitis is a chronic inflammatory condition associated with dysbiosis of the oral microbiota. The aim of the present clinical study was to explore the adjunctive effect of ozonized water irrigation in the circuits of ultrasonic scalers for the full-mouth decontamination of patients with periodontitis Stage I or II. Methods: The study was a randomized, single-blinded, parallel-group clinical trial. The test group (n=25) was treated with ultrasonic scalers irrigated with ozonized water, whereas the control group (n=25) received normal tap water irrigation within the ultrasonic scalers used during the professional mechanical debridement. Full mouth plaque score, bleeding score, probing pocket depth, and the gingival index were evaluated at baseline, two, and 4 weeks after treatment. The pain perceived and dental anxiety were also assessed after treatment by means of the visual analog scale (VAS). Results: All periodontal parameters resulted in significant improvement for both study groups. The effect of the treatment group on the gingival index was significant, in particular, patients in the test group experienced a greater reduction in this score. No significant differences could be observed with regards to the average probing depth, full mouth plaque index and bleeding score. Patients treated with ozonized water running in the circuits of ultrasonic scalers displayed also lower scores for pain and dental anxiety. Conclusion: The present study showed a significant clinical effect on gingival inflammation attributable to adjunctive ozone irrigation during nonsurgical periodontal therapy. Further studies, including patients with severe periodontitis and greater sample sizes, are recommended to test the clinical effect of ozonized water in the circuits of ultrasonic scalers.

초음파 조사시간에 따른 Microcystis aeruginosa의 성장억제 평가 (Evaluation of Growth Inhibition for Microcystis aeruginosa with Ultrasonic Irradiation Time)

  • 강은별;주진철;장소예;고현우;박정수;정무일;이동호
    • Ecology and Resilient Infrastructure
    • /
    • 제9권3호
    • /
    • pp.183-193
    • /
    • 2022
  • 초음파 (ultrasonic) 조사시간 (irradiation time)에 따른 Microcystis aeruginosa (M. aeruginosa)의 성장억제 (growth inhibition) 효과를 대용량 (10 L) 조류 시료를 활용해 다양한 초음파 조사시간 동안 (0.5, 1, 1.5, 2, 2.5, 3 hr) 실험실 규모 (lab-scale) 실험을 진행하였다. Chl-a와 M. aeruginosa 개체수 (cell number) 분석 결과, 초음파 조사 종료 이후 모든 실험군에서 Chl-a와 개체수가 감소되어 조류 성장억제가 관찰되었으며, 초음파 조사시간이 2시간 미만인 실험군 (T_B, T_C, T_D)은 저감 이후 조류의 급격한 재성장 (regrowth)이 관측되었으나, 조사시간이 2시간 이상인 실험군 (T_E, T_F, T_G)은 2시간 미만 조사한 실험군 대비 조류성장억제가 1 - 2일 더 지속되는 것을 확인하였다. 또한, 조류의 개체수가 초기 개체수까지 회복 시간 (recovery time)을 검토한 결과 조사시간 2시간을 기준으로 실험군 T_B (0.5 hr)는 7일, T_C (1 hr)와 T_D (1.5 hr)는 약 20일, T_E, T_F, T_G (≥ 2 hr)는 약 30일이 소요되어 초음파 조사 종료 후 초기 개체수까지의 회복 시간의 차이를 확인하였다. 비성장속도 (𝜇)와 일차분해속도(𝜅)를 도출한 결과, 실험군은 성장억제 기간 동안 초음파 조사시간과 비례하여 높은 일차분해율이 도출되었으며, 조사시간이 2시간 이상인 실험군의 재성장 시 비성장속도 (𝜇)는 2시간 미만인 실험군 대비 비성장속도 (𝜇)가 상대적으로 낮은 것으로 확인되었다. 따라서 정체수역 내 장기적인 (30일) 조류 성장억제를 위해서는 최소한 2시간 이상의 초음파 조사가 필요한 것으로 판단되나, 조류 성장억제를 위한 적정 초음파 조사시간은 정체수역의 규모, 수심, 흐름속도, 조류 농도 등의 다양한 현장조건에 따라 결정돼야 하며, 실제 적용 가능성을 높이기 위한 추가 연구가 필요한 것으로 판단된다. 초음파의 영향으로 인한 M. aeruginosa의 세포 표면 및 내부형질 변화를 관찰한 결과, 조류 세포 표면 및 세포막의 손상이 명확히 관측되었으며, 대조군 대비 실험군의 M. aeruginosa의 기낭 파괴 및 교란이 확인되었다.