• Title/Summary/Keyword: Ultrasonic pre-treatment

Search Result 36, Processing Time 0.029 seconds

Effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength and bond failure mode of metallic orthodontic brackets

  • Bonetti, Giulio Alessandri;Parenti, Serena Incerti;Ippolito, Daniela Rita;Gatto, Maria Rosaria;Checchi, Luigi
    • The korean journal of orthodontics
    • /
    • v.44 no.1
    • /
    • pp.44-49
    • /
    • 2014
  • Objective: To evaluate the effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength (SBS) and bond failure mode of metallic orthodontic brackets. Methods: Adhesive pre-coated metallic brackets were bonded to 72 extracted human premolars embedded in autopolymerizing acrylic resin. The teeth were randomly divided into 3 groups (n = 24 each) to undergo no treatment (control group) or ultrasonic instrumentation with a scaler-tip angulation of $45^{\circ}$ ($45^{\circ}$-angulation group) or $0^{\circ}$ ($0^{\circ}$-angulation group). SBS was tested in a universal testing machine, and adhesive remnant index (ARI) scores were recorded. The Kruskal-Wallis test and Mann-Whitney U-test were used for statistical analysis. Results: The control group had a significantly higher mean SBS value than the treated groups, which showed no significant differences in their mean SBS values. The ARI scores were not significantly different among the groups. Conclusions: Ultrasonic instrumentation around the bracket base reduces the SBS of metallic orthodontic brackets, emphasizing the need for caution during professional oral hygiene procedures in orthodontic patients. The scaler-tip angulation does not influence the SBS reduction and bond failure mode of such brackets.

Pre-treatment Technology of Wastewater Sludge for Enhanced Biogas Production in Anaerobic Digestion (혐기소화에서의 바이오가스 생산 증진을 위한 슬러지 전처리 기술)

  • Kim, Dong-Jin
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.355-369
    • /
    • 2013
  • Economic feasibility is one of the most important factors in energy production from regenerative biomass. From the aspect, biogas from anaerobic digestion of wastewater sludge is regarded as the most economical because of its cheap substrate and additional income from the disposal of waste sludge. Sludge hydrolysis has been regarded as the rate limiting step of anaerobic digestion and many sludge pre-treatment technologies have been developed to accelerate anaerobic sludge digestion for enhanced biogas production. Various sludge pre-treatment technologies including biological, thermo hydrolysis, ultrasonic, and mechanical methods have been applied to full-scale systems. Sludge pre-treatment increased the efficiency of anaerobic digestion by enhancing hydrolysis, reducing residual soilds, and increasing biogas production. This paper introduces the characteristics of various sludge pre-treatment technologies and the energy balance and economic feasibility of each technology were compared to prepare a guideline for the selection of feasible pre-treatment technology. It was estimated that thermophilic digestion and thermal hydrolysis were most economical technology followed by Cell rupture$^{TM}$, OpenCEL$^{TM}$, MicroSludge$^{TM}$, and ultrasound. The cost for waste sludge disposal shares the biggest portion in the economic analysis, therefore, water content of the waste sludge was the most important factor to be controlled.

A Comparison of Effectiveness of Gracey Curet and Ultrasonic Curet on Subgingival Scaling and Root Planning (치은 연하 치석 제거와 치근면 활택술시 Gracey curet과 Ultrasonic curet의 치석 제거에 효과에 대한 비교 연구)

  • Chung, Suk-Hyung;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.257-269
    • /
    • 2001
  • Removal of subgingival calculus is essential for the success in periodontal treatment. Subgingival instrumentation is used for the removal of all bacterial plaque and calculus. In this study, Gracey curet and Ultrasonic curet were used on single rooted teeth to conduct subgingval scaling and root planning. The remaining amount of calculus was evaluated according to type of instrument, depth of pocket, and tooth surface. 24 teeth were extracted from 14 patients being treated at department Periodontology Seoul Advantist dental hospital were used. Total 96 area(4 surface per teeth) were evaluated. 12 teeth treated with Gracey curet were used as the control group and the other 12 teeth treated with Ultrasonic curet were examined for experimental group. The 4 surface of the teeth(buccal, mesial, lingual or palatal, distal) were observed through the stereomicroscope and the images of the surface were captured and saved in CCD. The images were displayed on the monitor and the amount of calculus remained was evaluated by overlapping $10{\times}10$ grid pixel screen produced by Microsoft power point. The results evaluated were as follows 1. There was no statistically significant difference in residual calculus and tooth position following scaling and root planning of all group, but statistically significant correlation with residual calculus, probing depth, instruments and tooth surface. 2. There was statistically significant correlation between residual calculus and probing depth, but no statistically significant difference in residual calculus, tooth surface and tooth position on experimental(Ultrasonic curet) group. 3. There was no statistically significant difference in residual calculus according to the pre-treatment pocket depth and tooth position, but statistically significant correlation with tooth surface. The amount of residual calculus increase with mesial, distal, buccal and lingual(or palatal) surface on control(Gracey curet) group. 4. The Gracey showed better results than ultrasonic curet in mesial and distal surface, and there is significant difference. The results demonstrate that ultrasonic curet alone is inadequate for thorough subgingival debridement and suggest that Ultrasonic curet with Gracey curet should be more effective.

  • PDF

Preparation of Nano-sized MgxNiyZn1-x-yFe2O4 by Ultrasonic Wet-Magnetic Separation Method (초음파 습식 자기분류법을 이용한 MgxNiyZn1-x-yFe2O4 나노입자 제조)

  • Gu, Moon Sun;Kwon, Hyuk Joo;Choi, Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.3
    • /
    • pp.212-218
    • /
    • 2017
  • $Mg_xNi_yZn_{1-x-y}Fe_2O_4$ ferrite powders were prepared by self-propagating high temperature synthesis followed by classifying with an ultrasonic wet-magnetic separation unit to get high pure nano-sized particles. The $Mg_xNi_yZn_{1-x-y}Fe_2O_4$ ferrites were well formed by using several powders like iron, nickel oxide, zinc oxide and magnesium oxide at 0.1 MPa of oxygen pressure. The ultrasonic wet-magnetic separation of pre-mechanical milled ferrite powders resulted in producing the powders with average size of 800 nm. The addition of a surfactant during the wet-magnetic separation process improved productivity more than twice. The coercive force, maximum magnetization and residual magnetization of the $Mg_xNi_yZn_{1-x-y}Fe_2O_4$ nano-powders with 800 nm size were 3651 A/m, $53.92Am^2/kg$ and $4.0Am^2/kg$, respectively.

Inactivation of Mycobacterium using Ultrasonic and Ultraviolet Sequential Processes (초음파와 자외선 연계공정을 이용한 Mycobacterium 불활성화)

  • Kim, Wangi;Jung, Yeonjung;Yoon, Yeojoon;Lim, Gwanhun;Kim, Jongbae;Kang, Joon-Wun
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.57-62
    • /
    • 2012
  • In this study, the inactivation efficiency of Mycobacterium marinum was evaluated in buffered water (pH 7) using a low pressure ultraviolet (LP-UV) lamp, ultrasonic (US), and UV/US sequential processes. In the UV alone process, 3 log inactivation of the M. marinum was achieved with a UV dose of $120mJ/cm^2$. However, a tailing phase was later observed because M. marinum has a high tendency for cell aggregation. Even though the M. marinum was not inactivated in the US alone process, the hydrophobicity decreased and turbidity increased due to the crumbling of the cell aggregation. Among the candidate processes which were UV alone, US-UV sequential process and UV-US-UV sequential process, the US-UV sequential process showed the highest synergistic effects for M. marinum inactivation. Consequently, US is a very useful process as a UV irradiation pre-treatment to inactivate M. marinum in water.

Change of Solubilization Characteristics of Rice Straw by Different Pre-treatments (전처리 방법에 따른 볏짚의 가용화 특성 변화)

  • Hong, Seung-Gil;Shin, JoungDu;Heo, Jeong-Wook;Park, Woo-Kyun;Kwon, Soon-Ik;Park, Noh-Back;Shin, Hyun-Seon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.1
    • /
    • pp.71-77
    • /
    • 2012
  • In order to find a feasibility of applying an agricultural biomass to the anaerobic digestion system, the effects of pre-treatment of rice straw was investigated by different sizes,temperatures, ultrasonic frequencies, and with/without NaOH treatment on the change of soluble organic matter, which is generated most dominantly in Korea. It was observed that SCOD(soluble chemical oxygen demand) as the index for the decomposition of rice straw increased with the smaller particle size, higher reaction temperature and alkali treatment. With treatment of 5% NaOH, it was shown that the highest concentrations of SCOD were observed at 9,000 mg $L^{-1}$ and 6,000mg $L^{-1}$ at $35^{\circ}C$ and $55^{\circ}C$, respectively. Agitating with ultrasonic irradiation could be enhanced SCOD of rice straw less than 3 cm with 40 kHz of ultrasound. Optimal RPM in this study was at 150 rpm regardless of reaction temperatures.

Effective Component Contents and Antioxidative Activities of Unripe Apple by Extraction Methods (추출방법에 따른 미숙사과 추출물의 유용성분 함량 및 항산화 활성)

  • Hong, Jeong Jin;Seol, Hui Gyeong;Oh, Ju Youl;Jeong, Eun Ho;Chang, Young Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.34 no.2
    • /
    • pp.174-180
    • /
    • 2021
  • The purpose of this study was to determine the optimum extraction method suitable for the availability of biological activities in unripe apples known to be rich in functional components. Unripe apples 'Hongro' picked on May 28th, 2019 were extracted by various extraction methods (hot water, ethanol, enzymatic pre-treatment, ultrasonic wave, and subcritical water) and their extracts were investigated yield, effective component contents, and antioxidant activities. Overall, the yields by the extraction solvent were higher in water than in organic solvent(ethanol) because water-soluble compounds were eluted from a polar solvent. Total phenol contents of the ultrasonic wave (ethanol) extracts were significantly higher in 6 times than hot water extract. Contents of flavonoid were highest in the ethanol extract at 29.14 mg QE/g. Contents of tannin and ursolic acid were also significantly higher in the ultrasonic wave (ethanol) extract. The DPPH radical and ABTS radical scavenging activities were the strongest in the ultrasonic wave (ethanol) extract. Correlation between effective components and antioxidant activities was high in the total phenol content with ABTS and the ursolic acid content with DPPH (p<0.01). The above results suggested that ultrasonic wave (ethanol) extract of unripe apples has the potential to act as a functional material.

Biological Hydrogen Production from Mixed Organic Waste of Food and Activated Sludge by Pre-treatment (음식물쓰레기와 전처리한 폐활성슬러지의 혼합비율에 따른 생물학적 수소생산)

  • Lee, Jun-Cheol;Kim, Jae-Hyung;Choi, Kwang-Keun;Pak, Dae-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.9
    • /
    • pp.1044-1050
    • /
    • 2007
  • In this study, Bio-hydrogen is produced from organic waste mixtures containing food waste and waste activated sludge (WAS). The effects of different operational factor on hydrogen production, including various solubilization methods for pretreatments of WAS, pH and different ratios of food waste and WAS, were investigated. The highest hydrogen production values are obtained as 4.3 mL $H_2/g$ $VS_{consumed}$ in the case of applying the mixed pre-treatments of alkali and ultrasonic. The pH value in bio-reactor increased from 4 to 8 after the ultrasonic treatment with alkali and the hydrogen yield touched its highest value in the pH range of 5.0 to 5.5. Similarly, the hydrogen production reached the level of 13.8 mL $H_2/g$ $VS_{consumed}$ using the same pre-treatment method from the mixture of food waste and WAS. The ratio of 2 : 1 produced a maximum amount of hydrogen of 5.0 L $H_2/L/d$. The amount of volatile fatty acids(VFAs) including acetate, propionate and butyrate, were also varied considerably. Propionate decreased consistently with rising of hydrogen while butyrate comparing to acetate relatively increased in the effluent.

Electrode bonding method and characteristic of high density rechargeable battery using induction heating system (유도 가열 접합 시스템을 이용한 대용량 이차전지 전극의 접합 방법 및 특성)

  • Kim, Eun-Min;Kim, Shin-Hyo;Hong, Won-Hee;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.688-697
    • /
    • 2014
  • In this study, electrode bonding technology needed for high density of rechargeable battery is studied, which is recently researched for electric vehicle, the small leisure vessel. For the alternative overcoming the limit of stacking amount able to be stacked by conventional ultrasonic welding, the low temperature bonding method, eligible for minimum of degeneration of chemical activator on the electrode surface which is generated by thermal effect as well as the increase of conductivity and tension strength caused by electrode bonding using filler metal, not using conventional direct heating on the electrode material method, is studied. Specifically to say, recently used more generally the ultrasonic welding and spot welding method are not usable for satisfying stable electric conductivity and bonding strength when much electrode is stacking bonded. If the electrical power is unreasonably increased for the welding, due to the effect of welding temperature, deformation of electrode and activating material degeneration are caused, and after the last packaging, decline of electrical output and generating heat cause to reduce stability of battery. Therefore, in this study, induction heating system bonding method using high frequency heating and differentiated electrode method using filler metal pre-treatment of hot dipping are introduced.

Improved Cleaning Method for Dental Instruments

  • Kim, In-Geol;Lee, Yun-Ji
    • Journal of Korean Dental Science
    • /
    • v.3 no.2
    • /
    • pp.26-33
    • /
    • 2010
  • We searched at the "PubMed.gov" and "jendodon.com" sites to conduct a literature review on dental instruments that are reused in clinical settings and on infection control involving pre-disinfection or sterilization cleaning/rinsing. The keyword "dental clean" was used for the Web search. We found the present official definition of instrument cleaning performed prior to disinfection or sterilization rather limiting ("removal of foreign matter (soil, organism, etc.) from the instruments"). Thus, we proposed to expand the definition to include the removal of oils applied to protect the metallic instruments and from corrosion, stains, and rust resulting from the frequent reuse of the instruments. Clinicians are found to clean their dental instruments (a) immediately after treating their patients or (b) following their treatment but not immediately afterward. In the latter case, we recommend presoaking to be added. Ultrasonic sterilization of 5~15 minutes is found to be more effective in terms of eliminating residual matter from the instruments compared to other methods. To check on the cleaning results, we recommend visual inspection, which can be quick and practical in clinical settings. The latest products being developed and marketed on the market address the related problems. Nonetheless, research must be continued on the effects of presoak, cleaning/rinsing, disinfection, and high-temperature or heating-based sterilization on the dental instruments and on dental clinicians' practices in cleaning, disinfection, and sterilization. We advise dental clinicians to select the proper cleaning methods and detergents for their instruments to help eliminate or prevent corrosion, staining, and rusting, to reduce the maintenance costs, and to ensure user-friendly instruments/apparatuses.