• Title/Summary/Keyword: Ultrasonic absorption

Search Result 86, Processing Time 0.025 seconds

Angular Dispersion-type Nonscanning Fabry-Perot Interferometer Applied to Ethanol-water Mixture

  • Ko, Jae-Hyeon;Kojima, Seiji
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.261-266
    • /
    • 2009
  • The angular dispersion-type non-scanning Fabry-Perot was applied to an ethanol-water mixture in order to investigate its acoustic properties such as the sound velocity and the absorption coefficient. The scattered light from the mixture was analyzed by using the charge-coupled-device area detector, which made the measurement time much shorter than that obtained by using the conventional scanning tandem multi-pass Fabry-Perot interferometer. The sound velocity showed a deviation from ultrasonic sound velocities at low temperatures accompanied by the increase in the absorption coefficient, indicating acoustic dispersion due to the coupling between the acoustic waves and some relaxation process. Based on a simplified viscoelastic theory, the temperature dependence of the relaxation time was obtained. The addition of water molecules to ethanol reduced the relaxation time, consistent with dielectric measurements. The present study showed that the angular dispersion-type Fabry-Perot interferometer combined with an area detector could be a very powerful tool in the real-time monitoring of the acoustic properties of condensed matter.

Properties of concrete incorporating granulated blast furnace slag as fine aggregate

  • Patra, Rakesh Kumar;Mukharjee, Bibhuti Bhusan
    • Advances in concrete construction
    • /
    • v.5 no.5
    • /
    • pp.437-450
    • /
    • 2017
  • The present work investigates about the development of a novel construction material by utilizing Granulated Blast Furnace Slag (GBS), an industrial waste product, as substitution of natural fine aggregates. For this, experimental work has been carried out to determine the influence of GBS on the properties of concrete such as compressive strength (CS), modulus of elasticity, ultrasonic pulse velocity (UPV), chloride penetration, water absorption (WA) volume of voids (VV) and density. Concrete mixes of water/cement (w/c) ratios 0.45 and 0.5, and incorporating 20%, 40% and 60% of GBS as partial replacement of natural fine aggregate (sand) are designed for this study. The results of the experimental investigation depict that CS of concrete mixes increases with the increasing percentages of GBS. Moreover, the decrease in chloride penetration, WA and VV, and improvement in the modulus of elasticity, UPV, density of concrete is reported with the increasing percentage of GBS in concrete.

Ultrasonic relaxation associated with the complex formation of benzoic acid derivative and β-cyclodextrin (벤조산 유도체와 베타 사이클로덱스트린의 복합체 형성반응에 의한 초음파 완화)

  • Park, Shin;Bae, Jongrim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.6
    • /
    • pp.387-393
    • /
    • 2017
  • The dynamic interactions between benzoic acid derivative ($pH{\approx}7.0$)(guest) and ${\beta}$-cyclodextrin (${\beta}$-CD)(host) were investigated in an aqueous solutions in terms of ultrasonic absorption in the frequency range 0.2 MHz ~ 50 MHz with emphasis on the low-frequency range below 1 MHz at $25^{\circ}C$. We show that the interaction of ${\beta}$-CD and benzoic acid derivative complies with a typical spectrum of a single relaxation process around a few MHz. The ultrasonic relaxation observed in these solutions was due to a perturbation of a chemical equilibrium related to a reaction of an inclusion complex formed by the host and guest. The rate constant ($k_b=7.48{\times}10^6M^{-1}s^{-1}$) and equilibrium constant ($K=68.6M^{-1}$) were determined from the concentration dependences of benzoic acid on the relaxation frequency. The standard volume change (${\Delta}V=10.6{\times}10^{-6}m^3mol^{-1}$) of the reaction was also computed from the maximum absorption per wavelength. It was found that the hydrophobicity of guest molecules played an important role in the formation of the inclusion complex.

Temperature variation due to ultrasonic absorption in protein (초음파 흡수에 의한 단백질에서의 온도 변화 특성)

  • 신동욱
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.159-164
    • /
    • 1993
  • 초음파 흡수에 의한 단백질에서의 온도 변화 특성을 관측하기 위하여, 간단한 조직의 형태인 계란 흰자와 계란 흰자의 주성분인 물과 알부민 수용액을 시료로 선택하여, 초음파 흡수에 의한 온도 변화 특성을 물리 음향학적으로 관측하였다. 수 MHz의 초음파를 집속형 변환기에서 연속파의 형태로 시료에 투사하였을 때, 한정된 시료에서의 온도 변화를 측정하였다. 측정결과, 물과 알부민 성분에 의한 온도 증가 효과는 미미함을 알 수 있었다. 초음파 흡수에 의한 계란 흰자에서의 온도 변화는 단백질의 주성분인 알부민에 의한 효과보다는, 단백질을 구성하고 있는 각 성분들의 결합에 의한 효과가 큼을 알 수 있다. 이들 결과에 대한 이론적 검토로부터 초음파 흡수에 의한 인체내 온도 변화 및 부작용에 대한 초음파 강도의 안전기준의 토대 마련이 가능함을 제시하였다.

  • PDF

A Study on Development of Composite Ultrasonic Transducer Assembly with Drug Transfer Function (약물 이송기능을 갖는 복합구조 초음파 변환기 어셈블리 개발에 관한 연구)

  • Noh, Si-Cheol;Kim, Ju-Young;Yoo, Byeong-Cheol;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.353-359
    • /
    • 2017
  • The sonophoresis, a representative low-intensity ultrasonic therapy, is a technique for delivering the drugs into the epidermis, dermis and skin appendages by using physical vibration and heat effects of the ultrasonic waves. Sonophoresis could increases the delivering and absorption efficiency of the drugs usually consisting of hydrophilic molecules and macromolecules. In addition, it has the advantage of being effective in delivering drugs with relatively large molecular sizes such as insulin or lipid. In this study, we proposed a multi-structure ultrasonic transducer assembly with a large-size single piezoelectric element and a drug delivery function at the treatment site for efficient sonophoresis treatment. Futhermore, a transducer assembly structure capable of raising and maintaining the temperature of the treatment site was proposed and evaluated for effectiveness. The transducer assembly proposed in this study is expected to improve the efficiency of sonophoresis by providing a constant amount of drug, and assisting drug delivery through heating the treatment site.

Assessment of Uterine Internal Temperature according to the Time of Convex Probe Injection using a Self-made Uterine Model Phantom (자체 제작한 자궁모형팬텀을 이용한 Convex probe 주사시간에 따른 자궁내부온도 평가)

  • Lee, Hyun-Kyung;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.895-900
    • /
    • 2019
  • Ultrasound is known to be harmless to the human body and is widely used in obstetrics and gynecology to confirm the diagnosis and development status of fetus. Diagnosis Although long - term use of ultrasound may cause changes in body temperature, studies on the uterine temperature changes due to ultrasound have been lacking. The purpose of this study was to investigate the change of temperature according to ultrasonic scanning time using a self - produced uterine model phantom. Ultrasound equipment and a 4MHz convex probe were used to construct the uterine model phantom similar to the human uterus using acrylic and pig uterus, which are tissue equivalents. Three probe type thermometers were installed to measure the inside of the acrylic water tank, the uterus, and the atmospheric temperature. The temperature of the uterine phantom was ascertained by measuring the temperature of the subject for 6 hours, 361 times. In this study, the possibility of human body temperature elevation due to ultrasound could be confirmed and this study will be used as the basic data of ultrasonic heat absorption study.

Development of UV Corona Camera for the Detecting of Discharge on Power Facility using UV Transmittance Improvement Filter (UV 투과율 향상 필터 기술을 이용한 전력설비 방전 검출용 자외선 코로나 카메라 개발)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1656-1661
    • /
    • 2012
  • UV inspection technology is being used for predictive maintenance of power facility together with IR-thermography and ultrasonic devices. In this paper, the UV corona camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. The UV corona camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The transmission between 250 to 280nm was 11% ($12.5%{\times}88%{\times}98%$) by combing the transmission on absorption film, window and other filter(UG 5, nickel sulphate and so on). In a distance of 5m with the UV corona camera it is possible to detect partial discharge with a PD level of 2.5pC and a RIV level of $3.6dB{\mu}V$.

Chip on Glass Interconnection using Lateral Thermosonic Bonding Technology (횡방향 열초음파 본딩 기법을 이용한 COG 접합)

  • Ha, Chang-Wan;Yun, Won-Soo;Park, Keum-Saeng;Kim, Kyung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.7
    • /
    • pp.7-12
    • /
    • 2010
  • In this paper, chip-on-glass(COG) interconnection with anisotropic conductive film(ACF) using lateral thermosonic bonding technology is considered. In general, thermo-compression bonding which is used in practice for flip-chip bonding suffers from the low productivity due to the long bonding time. It will be shown that the bonding time can be improved by using lateral thermosonic bonding in which lateral ultrasonic vibration together with thermo-compression is utilized. By measuring the internal temperature of ACF, the fast curing of ACF thanks to lateral ultrasonic vibration will be verified. Moreover, to prove the reliability of the lateral thermosonic bonding, observation of pressured mark by conductive particles, shear test, and water absorption test will be conducted.

Mechanical and durability properties of concrete incorporating glass and plastic waste

  • Abdelli, Houssam Eddine;Mokrani, Larbi;Kennouche, Salim;Aguiar, J.L. Barroso de
    • Advances in concrete construction
    • /
    • v.11 no.2
    • /
    • pp.173-181
    • /
    • 2021
  • The main objective of this work is to contribute to the valorization of plastic and glass waste in the improvement of concrete properties. Waste glass after grinding was used as a partial replacement of the cement with a percentage of 15%. The plastic waste was cut and introduced as fibers with 1% by the total volume of the mixture. Mechanical and durability tests were conducted for various mixtures of concrete as compressive and flexural strengths, water absorption, ultrasonic pulse velocity, and acid attack. Also, other in-depth analyses were performed on samples of each variant such as X-ray diffraction (XRD), thermogravimetric analysis (DSC-TGA), and scanning electron microscope (SEM). The results show that the addition of glass powder or plastic fibers or a combination of both in concrete improved in the compression and flexural strengths in the long term. The highest compressive strength was obtained in the mix which combines the two wastes about 26.72% of increase compared to the control concrete. The flexural strength increased in the mixture containing the glass powder. Therefore, the mixture with two wastes exhibits better resistance to aggressive sulfuric acid attack, and incorporating glass powder improves the ultrasonic pulse velocity.

Variations of Engineering Geological Characteristics of the Cretaceous Shale from the Pungam Sedimentary Basin in Kangwon-do due to Freezing-Thawing (강원도 횡성군 풍암분지 백악기 셰일의 동결-융해에 따른 지질공학적 특성 변화)

  • Jang Hyun-Shic;Jang Bo-An;Lee Jun-Sung
    • The Journal of Engineering Geology
    • /
    • v.14 no.4 s.41
    • /
    • pp.401-416
    • /
    • 2004
  • We have collected shale specimens from the Pungam Basin in Kangwon province and investigated change of physical properties by freezing and thawing in water as well as in acidic fluid. The temperature range was $-20{\pm}2^{\circ}C\~15{\pm}2^{\circ}C$. Specimens were frozen for 12 hours and thawed in water for 8 hours. Then, they were saturated in the vacuum chamber for 4 hours to make specimens fully saturated. This procedure was 1 cycle. We have measured absorption, ultrasonic velocity, shore hardness, slake durability and uniaxial compressive strength at every 5th cycles. The physical properties increased or decreased as freezing and thawing cycles increased. Uniaxial compressive strength decreased by 0.40MPa per cycle in water and by 0.48MPa in acidic fluid. Elastic constant also decreased by 0.21GPa per cycle in water and by 0.30GPa in acidic fluid. Absorption increased by $0.29\%$ and $0.37\%$ per cycle in water and acidic fluid, respectively. These results indicate that decrease in uniaxial compressive strength, elastic constant and absorption by freezing and thawing in acidic fluid is more rapid than in water. Ultrasonic velocities, shore hardness and slake durability show no differences in water and acidic fluid. When we compared our results with the temperatures in the Hongchon during the winter season, $6\~12$ cycles may be equivalent to 1 year.