• Title/Summary/Keyword: Ultrasonic Actuator

Search Result 97, Processing Time 0.022 seconds

A Study on a Ultrasonic Vibration Assisted Grinding of Alumina Ceramic with Diamond Grinding Tool (초음파 진동을 하는 다이아몬드 연삭공구의 알루미나 세라믹 연삭 가공에 관한 연구)

  • Choi, Young-Jae;Song, Ki-Hyeong;Park, Kyung-Hee;Hong, Yun-Hyuck;Kim, Kyeong-Tae;Lee, Seok-Woo;Choi, Hon-Zong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.1
    • /
    • pp.13-19
    • /
    • 2012
  • In this study, ultrasonic vibration tool designed and made by using FEM analysis. And machining test was carried out in various machining conditions using ultrasonic vibration capable CNC machine. For work material, alumina ceramic ($Al_2O_3$) was used while for tool material diamond electroplated grinding wheel was used. To evaluate ultrasonic vibration effect, grinding test was performed with and without ultrasonic vibration in same machining condition. In ultrasonic mode, ultrasonic vibration of 20kHz was generated by HSK 63 ultrasonic actuator. The two grinding speeds, 1.67m/s and 3.35m/s, were applied. On the other hand, grinding forces were measured by KISTLER dynamometer.

Development of a Master-Slave System for Active Endoscope Using a Multi-DOF Ultrasonic Motor

  • Takemura, Kenjiro;Harada, Dai;Maeno, Takashi
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.17-22
    • /
    • 2002
  • Endoscopes for industrial and medical fields are expected to have multi degree-of-freedom (DOF) motions. A multi-DOF ultrasonic motor we developed consists of a spherical rotor and a bar-shaped stator, and the rotor rotates around three perpendicular axes using three natural vibration modes of the stator. In this study, a multi-DOF unilateral master-slave system for active endoscope using the multi-DOF ultrasonic motor is developed. The configurations of master and slave arms for active endoscope are similar, so that an operator can easily handle the master-slave system. First, driving characteristics of the multi-DOF ultrasonic motor are measured in order to design the slave arm and its controller. Next, the master arm and the slave arm are designed. Then, the unilateral feedback controller for the master-slave system is developed. Finally, the motion control tests of rotor are conducted. As a result, the possibility of the endoscope is confirmed.

Friction-Based and Acoustically-Levitated Object Transport Using Ultrasonic Vibration (초음파 진동을 이용한 마찰 및 음향부상에 의한 물체의 수송)

  • Byoung-Gook Loh;Yong-Kuk Park
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.590-599
    • /
    • 2003
  • In this study. object transport method based on ultrasonic flexural vibration is presented. Ultrasonic vibration generates ultrasonic traveling waves on the surface of elastic medium. Objects are transported through the interaction with traveling waves propagating in medium. Two types of transport methods are studied: frictional drive and acoustic levitation. With frictional drive, objects are transported in contact with the beam in the opposite direction of wave propagation whereas with acoustic levitation, objects are acoustically levitated above the beam surface and transported in the wave propagation direction. Transport characteristics are experimentally investigated using objects of different shapes and sizes. The transition from acoustic levitation mode to frictional drive mode is also examined. and it is found to occur when the ratio of mass to area of an object exceeds the threshold ratio of mass to area. It is envisaged that this feasibility study will serve as a stepping-stone for ultrasonic vibration to become an effective industrial material handling device in the future.

A Study on Ultrasonic Location in Underwater Using the Two Optical Fiber Sensors (수중에서 2개의 광섬유센서를 이용한 초음파 음원의 위치 검출에 관한 연구)

  • Kwon, Tae-Ho;Shin, Dae-Yong;Lee, June-Ho;Lee, Jong-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.62-66
    • /
    • 2002
  • The preliminary results on the application of optical fiber sensor(OFS) for locations of ultrasonic signals in underwater are presented and analyzed. The OFS utilizing the principle of Sagnac interferometry was designed and the hollowed cylindrical mandrel wound by single mode optical fiber was used as sensing component. The ultrasonic signal source was simulated by the PZT actuator operated with function generator. It has been shown that the OFS could detect the signals less affected by ultrasonic path comparing to conventional acousto-electric sensor and accurate location of ultrasonic signal could be carried out using two OFSs.

  • PDF

Analytical and higher order finite element hybrid approach for an efficient simulation of ultrasonic guided waves I: 2D-analysis

  • Vivar-Perez, Juan M.;Duczek, Sascha;Gabbert, Ulrich
    • Smart Structures and Systems
    • /
    • v.13 no.4
    • /
    • pp.587-614
    • /
    • 2014
  • In recent years the interest in online monitoring of lightweight structures with ultrasonic guided waves is steadily growing. Especially the aircraft industry is a driving force in the development of structural health monitoring (SHM) systems. In order to optimally design SHM systems powerful and efficient numerical simulation tools to predict the behaviour of ultrasonic elastic waves in thin-walled structures are required. It has been shown that in real industrial applications, such as airplane wings or fuselages, conventional linear and quadratic pure displacement finite elements commonly used to model ultrasonic elastic waves quickly reach their limits. The required mesh density, to obtain good quality solutions, results in enormous computational costs when solving the wave propagation problem in the time domain. To resolve this problem different possibilities are available. Analytical methods and higher order finite element method approaches (HO-FEM), like p-FEM, spectral elements, spectral analysis and isogeometric analysis, are among them. Although analytical approaches offer fast and accurate results, they are limited to rather simple geometries. On the other hand, the application of higher order finite element schemes is a computationally demanding task. The drawbacks of both methods can be circumvented if regions of complex geometry are modelled using a HO-FEM approach while the response of the remaining structure is computed utilizing an analytical approach. The objective of the paper is to present an efficient method to couple different HO-FEM schemes with an analytical description of an undisturbed region. Using this hybrid formulation the numerical effort can be drastically reduced. The functionality of the proposed scheme is demonstrated by studying the propagation of ultrasonic guided waves in plates, excited by a piezoelectric patch actuator. The actuator is modelled utilizing higher order coupled field finite elements, whereas the homogenous, isotropic plate is described analytically. The results of this "semi-analytical" approach highlight the opportunities to reduce the numerical effort if closed-form solutions are partially available.

Electrical Properties of Ring-type Multilayer Piezoelectric Actuator (원환형 적층 압전 액츄에이터의 전기적 특성)

  • Kim, Kook-Jin;Yoo, Ju-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.869-872
    • /
    • 2007
  • In this study, in order to develop low temperature sintering ultrasonic nozzle, single-layer and multilayer ring-type piezoelectric actuators were manufactured using PMN-PNN-PZT ceramics, And then the electrical properties were investigated. A ring-type piezoelectric actuator was modeled by ATILA program using finite element method(FEM). The piezoelectric actuator dimension was $\Phi26.5$ (outer diameter), $\Phi12$ (inner diameter), 3.5 mm (thickness). By FEM analysis, resonant and anti-resonant frequencies were appeared as 56.7 kHz and 61.5 kHz. The displacement increased with the increases of the number of layer. Based on the result, ring-type multilayer piezoelectric actuators were manufactured at low co-firing temperature of $940^{\circ}C$. The resonant resistance decreased with the increases of the number of layer. And also, the capacitance increased with the increases of the number of layer. The mechanical quality factor (Qm) decreased with the increases of the number of layer.

A Study on Force-Reflecting Interface using Ultrasonic Motros (초음파모터를 이용한 역감장치에 관한 연구)

  • 강원찬;김대현;김영동
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.123-128
    • /
    • 1998
  • This paper describes the evaluation of a force-reflecting interface with ultrasonic motors(USMs). The force-reflecting interface allows a human to feel object within virtual environment. To effectively display the mechanical impedance of the human hand we need a haptic device with specific characteristics, such as low inertia, almost zero friction and very high stiffness. USMs have attracted considerable attention as the actuator satisfied these conditions. USMs combine features such as high driving torque at low rotational speed, high holding torque and fast response therefore we studied two degree of freedom force-reflecting haptic system.

  • PDF

Micro Ultrasonic Elliptical Vibration Cutting (II) Ultrasonic Micro V-grooving Using Elliptical Vibration Cutting (미세 초음파 타원궤적 진동절삭 (II) 타원진동 절삭운동을 이용한 미세 홈 초음파 가공)

  • Kim Gi Dae;Loh Byoung-Gook;Hwang Kyung-Sig
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.198-204
    • /
    • 2005
  • For precise micro V-grooving, ultrasonic elliptical vibration cutting (UEVC) is proposed using two parallel piezoelectric actuators, which are energized by sinusoidal voltages with a phase difference of 90 degrees. Experimental setup is composed of stacked PZT actuators, a single crystal diamond cutting tool, and a precision motorized xyz stage. It is found that the chip formed in the process of UEVC is discontinuous because of the periodic contacts and non-contacts occurring between the tool and workpiece. It is experimentally observed that the cutting force in the process of UEVC significantly reduces compared to the ordinary non-vibration cutting. In addition, the creation of burr during UEVC is significantly suppressed, which is attributable to the decrease in the specific cutting energy.