• Title/Summary/Keyword: U-Printer

Search Result 27, Processing Time 0.022 seconds

Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer (DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

Evaluation of marginal and internal fit of metal copings fabricated by selective laser melting (SLM 방식으로 제작한 도재관 금속하부구조물의 변연 및 내면 적합도 평가)

  • Sung-Ryung Bae;Ha-Bin Lee;Mi-Jun Noh;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: To evaluate the marginal and internal fit of metal coping fabricated by a metal three-dimensional (3D) printer that uses selective laser melting (SLM). Methods: An extraoral scanner was used to scan a die of the prepared maxillary right first molar, and the coping was designed using computer-aided design software and saved as an stereo lithography (STL) file. Ten specimens were printed with an SLM-type metal 3D printer (SLM group), and 10 more specimens were fabricated by casting the castable patterns output generated by a digital light processing-type resin 3D printer (casting the 3D printed resin patterns [CRP] group). The fit was measured using the silicon replica technique, and 8 points (A to H) were set per specimen to measure the marginal (points A, H) and internal (points B~G) gaps. The differences among the groups were compared using the Mann-Whitney U-test (α=0.05). Results: The mean of marginal fit in the SLM group was 69.67±18.04 ㎛, while in the CRP group was 117.10±41.95 ㎛. The internal fit of the SLM group was 95.18±41.20 ㎛, and that of the CRP group was 86.35±32 ㎛. As a result of statistical analysis, there was a significant difference in marginal fit between the SLM and CRP groups (p<0.05); however, there was no significant difference in internal fit between the SLM group and the CRP group (p>0.05). Conclusion: The marginal and internal fit of SLM is within the clinically acceptable range, and it seems to be applicable in terms of fit.

The Proposal of a Small-Size Business Model based on a 3D Printer : Focused on Sunglasses for Children (3D 프린터를 활용한 소규모 비즈니스 모델 제안 : 유아동 선글라스를 중심으로)

  • Kim, Se-yeong;Kim, Suk-Rae
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.455-464
    • /
    • 2018
  • Recognizing the shortage of information about business models to generate profit despite the designers' recent interest in 3D printers as a new creative tool, this study set out to make sunglasses for young children, which lacked diversity in sizes according to age due to the small market scope under the old mass production system, by taking advantage of 3D printers' strength in the small batch production of customized products and propose a practical example to be expandable as a small-size business model. For these purposes, the investigator summarized the basic information about the 3D printing technology and the basic structure of sunglasses and made a size table to manufacture sunglasses for young children by analyzing the size table for vision correction. After this series of work, the study presented final product with the production costs and demonstrated that sunglasses for young children made with a 3D printer could be a practical case expandable as a competitive small-size business model in the market.

Comparison of three-dimensional adaptation as per the rinsing time of temporary crown manufactured using a digital light processing printer (디지털 광 조명 방식으로 제작한 임시 크라운의 세척 시간에 따른 3차원 적합도 평가)

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.334-340
    • /
    • 2020
  • Purpose: This study aimed to compare three-dimensional adaptation with the rinsing time of the temporary crown produced using the digital light processing method. Methods: The maxillary right first molar abutment was scanned with a dental scanner. A temporary crown was designed with the scanned abutment. The designed crown was made of 10 temporary crowns using a digital light processing printer. The crowns were divided into the 5-minute and 10-minute rinsing groups; 5 temporary crown washes were performed for each group. In order to obtain the internal data, each group was scanned for a temporary crown. The three-dimensional fit was measured by superimposing the scanned internal surface data and the abutment data. The average comparison of three-dimensional adaptation was analyzed using the Mann-Whitney U test. Results: The 5-minute rinsing group showed a significantly higher adaptation of 71.42±3.08 ㎛ as compared to the 10-minute rinsing group (67.52±0.92 ㎛) (p<0.05). Conclusion: When making a temporary crown with a digital light processing method, a rinsing time of 10 minutes is appropriate.

Accuracy of dies fabricated by various three dimensional printing systems: a comparative study (다양한 삼차원 프린팅 시스템으로 제작된 다이의 정확도 비교)

  • Baek, Ju Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.242-253
    • /
    • 2020
  • Purpose: The aim of this study was to compare the accuracy of dies fabricated using 3D printing system to conventional method and to evaluate overall volumetric changes by arranging the superimposed surfaces. Materials and Methods: A mandibular right first molar from a dental model was prepared, scanned and fabricated with composites of polyetherketoneketone (PEKK). Master dies were classified into 4 groups. For the conventional method, the impression was taken with polyvinylsiloxane and the impression was poured with Type IV dental stone. For the 3D printing, the standard die was scanned and converted into models using three different 3D printers. Each of four methods was used to make 10 specimens. Scanned files were superimposed with the standard die by using 3D surface matching software. For statistical analysis, Kruskal-Wallis test and Mann-Whitney U test were done (P < 0.05). Results: Compared to the standard model, the volumetric changes of dies fabricated by each method were significantly different except the models fabricated by conventional method and 3D printer of Stereolithography (P < 0.05). The conventional dies showed the lowest volumetric change than 3D printed dies (P < 0.05). 3D printed dies fabricated by Stereolithography showed the lowest volumetric change among the different 3D printers (P < 0.05). Conclusion: The conventional dies were more accurate than 3D printed dies, though 3D printed dies were within clinically acceptable range. Thus, 3D printed dies can be used for fabricating restorations.

METHYL MERCAPTAN CONCENTRATION DURING EXPERIMENTAL GINGIVITIS IN MAN (실험적 치은염에서 구강내 휘발성 메틸머캅단 농도 변화에 관한 연구)

  • Kim, Young-Jun
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.35-44
    • /
    • 1995
  • The purpose of present study was to evaluate the relationship between the early change of gingival condition and methyl mercaptan concentration during experimental gingivitis. Ten men(23-25 years old) whose gingiva were clinically healthy were selected. The participants have ceased to perform all forms of oral hygiene during 14 days and then did thorough plaque control for 7 days. For each subject, the methyl mercaptan concentration was measured by $B.B.Checker^{(R)}$ (Bad Breath Checker with printer, Tokuyama Soda Co.,LTD., Japan)before experiment and 1,4,7,14,21 days during experiment. Plaque index(Silness & $L\ddot{o}e$), gingival sulcus depth and sulcus bleeding index($M\ddot{u}hlemann$ & Son)score were recorded. The results were as follows. 1. Methyl mercaptan concentration increased continuously from the first day to the 14th day, decreased on the 21th day but it was still higher(P<0.001). 2. Plaque index score and sulcus bleeding index score tended to increase on the 4th day, markedly increased on the 14th day and returned to baseline level on the 21th day. 3. There was parallel relationhsip among methyl mercaptan concentration, plaque index score and sulcus bleeding index score. This result suggests that methyl mercaptan concentration increased with deterioration in gingival health, but decreased during recovery of normal health condition.

  • PDF

PostScript Conversion of ODIF Data Stream (ODIF 데이터스림의 포스트스크립트 변환)

  • 홍온선;윤근종;이수연
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.11
    • /
    • pp.1027-1036
    • /
    • 1991
  • This paper proposes an implementation of ODIF(Open Document Interchange Format)decoder and PostScript converter. AS ODIF data stream based on IS 8613 is described according to ASN.1 notation it is necessary to decode ODIF data stream to the proper internal structure to PostScript format as proposed in order to make hard copies in good quality using LBP(Laser Beam Printer). Among several kinds of DA(Document Architecture) and DAP(Document Application Profile). PDA(Processable DA) and Core 26(Level 2 DAP) are selected for our study. An ODIF data stream submitted by ICL is used to show the conformance in the level of data stream.

  • PDF

Structural Behavior Analysis of Polymer Lattice Reinforced 3D Printing Cementitious Cladding (폴리머 격자 보강재를 이용한 3D 프린팅 시멘트계 외장재의 구조 거동 분석)

  • Kim, Hak-Beom;Park, Min-Jae;Ju, Young K.
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.3-10
    • /
    • 2018
  • Cladding that finishes the exterior of a building could enhance the value of the building, and shape control is an important factor. With the recent development of 3D printing, cementitious claddings were printed by 3D printer in China, U.S.A and elsewhere. On the other hand, the structural safety of the exterior panel should be examined, as casualties occur when the exterior panel fails due to typhoon or impact. Cement-based cladding is reinforced by wire mesh to improve safety. Introducing 3D printing composite system with polymer and cement, makes it possible to produce claddings fast and accurate. Prior to the development of 3D printing cementitious cladding, the major parameters influencing the optimal shape were identified based on structural performance. The wind load, joint, and bond behavior between polymer and cement were considered. Polymer laminate shape, order, and thickness were variables, and finite element analysis was performed.

Tensile Tests for Copper Thin Foils by Using DIC Method (DIC 법을 이용한 구리박막의 인장시험)

  • Kim, Chung Youb;Song, Ji Ho;Park, Kyung Jo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1529-1534
    • /
    • 2012
  • In this study, tensile tests for 12-${\mu}m$-thick copper thin foils were performed by using the DIC method. The DIC method provided precise stress-strain curves for thin film materials, and a commercial inkjet printer can be simply and effectively used for printing speckle patterns on the specimen of Cu thin films whose surface contrast is too low to apply the DIC method. The mechanical properties of Cu thin foils obtained in this study are as follows: elastic modulus E = 89.2 GPa, 0.2% offset yield stress $S_{0.2%}$= 232.8 MPa, tensile strength $S_u$= 319.2 MPa, elongation at fracture ${\varepsilon}_f$=16.8 %, and Poisson's ratio ${\nu}$= 0.34.

The comparison of the accuracy of temporary crowns fabricated with several 3D printers and a milling machine

  • Junsik Lee;Sungwon Ju;Jihyung Kim;Sion Hwang;Jinsoo Ahn
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.2
    • /
    • pp.72-79
    • /
    • 2023
  • PURPOSE. The purpose of this in vitro study was to compare the accuracy of various 3D printers and a milling machine. MATERIALS AND METHODS. The die model was designed using CAD (Autodesk Inventor 2018 sp3). The 30 ㎛ cement space was given to the die and the ideal crown of the mandibular left first molar was designed using CAD (ExoCAD). The crowns were produced using the milling machine (Imes-icore 250i) and the 3D printers (Zenith U, Zenith D, W11) and they were divided into four groups. In all groups, the interior of each crown was scanned (Identica blue) and superimposed (Geomagic Control X) with the previously designed die. The difference between the die and the actual crown was measured at specific points. The Kruskal-Wallis test, the Mann-Whitney test, and Bonferroni's method were performed with a statistical analysis software (P < .008 in inter-group comparison P < .001 in intra-group comparison). RESULTS. In all groups, the center of the occlusal area and the anti-rotational dimple area showed significantly greater difference and the marginal area showed the smallest difference comparatively. The mean value of the difference in each area and the sum of the differences were higher in order of W11, Imes-icore 250i, Zenith D, and Zenith U. CONCLUSION. The digital light processing (DLP) method shows higher accuracy compared to the sereolithography (SLA) method using the same resin material.