DOI QR코드

DOI QR Code

Comparison of three-dimensional adaptation as per the rinsing time of temporary crown manufactured using a digital light processing printer

디지털 광 조명 방식으로 제작한 임시 크라운의 세척 시간에 따른 3차원 적합도 평가

  • Lee, Beom-Il (Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University) ;
  • You, Seung-Gyu (Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University) ;
  • You, Seung-Min (Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University) ;
  • Kim, Ji-Hwan (Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University)
  • 이범일 (고려대학교 일반대학원 보건과학과 치의기공전공) ;
  • 유승규 (고려대학교 일반대학원 보건과학과 치의기공전공) ;
  • 유승민 (고려대학교 일반대학원 보건과학과 치의기공전공) ;
  • 김지환 (고려대학교 일반대학원 보건과학과 치의기공전공)
  • Received : 2020.10.22
  • Accepted : 2020.12.07
  • Published : 2020.12.30

Abstract

Purpose: This study aimed to compare three-dimensional adaptation with the rinsing time of the temporary crown produced using the digital light processing method. Methods: The maxillary right first molar abutment was scanned with a dental scanner. A temporary crown was designed with the scanned abutment. The designed crown was made of 10 temporary crowns using a digital light processing printer. The crowns were divided into the 5-minute and 10-minute rinsing groups; 5 temporary crown washes were performed for each group. In order to obtain the internal data, each group was scanned for a temporary crown. The three-dimensional fit was measured by superimposing the scanned internal surface data and the abutment data. The average comparison of three-dimensional adaptation was analyzed using the Mann-Whitney U test. Results: The 5-minute rinsing group showed a significantly higher adaptation of 71.42±3.08 ㎛ as compared to the 10-minute rinsing group (67.52±0.92 ㎛) (p<0.05). Conclusion: When making a temporary crown with a digital light processing method, a rinsing time of 10 minutes is appropriate.

Keywords

References

  1. Nejatidanesh F, Lotfi HR, Savabi O. Marginal accuracy of interim restorations fabricated from four interim autopolymerizing resins. J Prosthet Dent. 2006;95:364-367. https://doi.org/10.1016/j.prosdent.2006.02.030
  2. Amin BM, Aras MA, Chitre V. A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: an in vitro study. Contemp Clin Dent. 2015;6:161-165. https://doi.org/10.4103/0976-237X.156035
  3. Karaokutan I, Sayin G, Kara O. In vitro study of fracture strength of provisional crown materials. J Adv Prosthodont. 2015;7:27-31. https://doi.org/10.4047/jap.2015.7.1.27
  4. Mai HN, Lee KB, Lee DH. Fit of interim crowns fabricated using photopolymer-jetting 3D printing. J Prosthet Dent. 2017;118:208-215. https://doi.org/10.1016/j.prosdent.2016.10.030
  5. Peng CC, Chung KH, Yau HT, Ramos V Jr. Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods. J Prosthet Dent. 2020;123:514-522. https://doi.org/10.1016/j.prosdent.2019.02.024
  6. You SM, You SG, Kang SY, Bae SY, Kim JH. Evaluation of the accuracy (trueness and precision) of a maxillary trial denture according to the layer thickness: an in vitro study. J Prosthet Dent 2020. https://doi.org/10.1016/j.prosdent.2019.12.014 [Epub ahead of print]
  7. Alharbi N, Osman R, Wismeijer D. Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations. J Prosthet Dent. 2016;115:760-767. https://doi.org/10.1016/j.prosdent.2015.12.002
  8. Kim DY, Jeon JH, Kim JH, Kim HY, Kim WC. Reproducibility of different arrangement of resin copings by dental microstereolithography: evaluating the marginal discrepancy of resin copings. J Prosthet Dent. 2017;117:260-265. https://doi.org/10.1016/j.prosdent.2016.07.007
  9. ASTM. Standard terminology for additive manufacturing-general principles-terminology. West Conshohocken (PA): ASTM International, 2015. Report No.: ISO/ASTM52900-15.
  10. You SG, You SM, Kang SY, Bae SY, Kim JH. Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: an in vitro study. J Prosthet Dent 2020. https://doi.org/10.1016/j.prosdent.2020.01.039 [Epub ahead of print]
  11. Alharbi N, Osman RB, Wismeijer D. Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology. Int J Prosthodont. 2016;29:503-510. https://doi.org/10.11607/ijp.4835
  12. Revilla-Leon M, Ozcan M. Additive manufacturing technologies used for processing polymers: current status and potential application in prosthetic dentistry. J Prosthodont. 2019;28:146-158. https://doi.org/10.1111/jopr.12801
  13. Yang Y, Yang Z, Zhou J, Chen L, Tan J. Effect of tooth preparation design on marginal adaptation of composite resin CAD-CAM onlays. J Prosthet Dent. 2020;124:88-93. https://doi.org/10.1016/j.prosdent.2019.08.010
  14. Wang W, Yu H, Liu Y, Jiang X, Gao B. Trueness analysis of zirconia crowns fabricated with 3-dimensional printing. J Prosthet Dent. 2019;121:285-291. https://doi.org/10.1016/j.prosdent.2018.04.012
  15. Alharbi N, Alharbi S, Cuijpers VMJI, Osman RB, Wismeijer D. Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs. J Prosthodont Res. 2018;62:218-226. https://doi.org/10.1016/j.jpor.2017.09.002
  16. Katheng A, Kanazawa M, Iwaki M, Minakuchi S. Evaluation of dimensional accuracy and degree of polymerization of stereolithography photopolymer resin under different postpolymerization conditions: an in vitro study. J Prosthet Dent 2020. https://doi.org/10.1016/j.prosdent.2020.02.023 [Epub ahead of print]
  17. Park GS, Kim SK, Heo SJ, Koak JY, Seo DG. Effects of printing parameters on the fit of implant-supported 3D printing resin prosthetics. Materials (Basel). 2019;12:2533. https://doi.org/10.3390/ma12162533
  18. Jeon JH. In vitro precision evaluation of blue light scanning of abutment teeth made with impressions and dental stone casts according to different 3D superimposition methods. J Prosthodont Res. 2020;64:368-372. https://doi.org/10.1016/j.jpor.2019.10.005
  19. Kang SY, Park JH, Kim JH, Kim WC. Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique. J Adv Prosthodont. 2018;10:354-360. https://doi.org/10.4047/jap.2018.10.5.354
  20. Kang SY, Park JH, Kim JH, Kim WC. Three-dimensional trueness analysis of ceramic crowns fabricated using a chairside computer-aided design/manufacturing system: an in vitro study. J Prosthodont Res. 2020;64:152-158. https://doi.org/10.1016/j.jpor.2019.06.004
  21. Ender A, Attin T, Mehl A. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. J Prosthet Dent. 2016;115:313-320. https://doi.org/10.1016/j.prosdent.2015.09.011
  22. Kaleli N, Ural C. Digital evaluation of laser scanning speed effects on the intaglio surface adaptation of laser-sintered metal frameworks. J Prosthet Dent. 2020;123:874.e1-874.e7. https://doi.org/10.1016/j.prosdent.2019.12.020
  23. O'Toole S, Osnes C, Bartlett D, Keeling A. Investigation into the accuracy and measurement methods of sequential 3D dental scan alignment. Dent Mater. 2019;35:495-500. https://doi.org/10.1016/j.dental.2019.01.012
  24. Martorelli M, Gerbino S, Giudice M, Ausiello P. A comparison between customized clear and removable orthodontic appliances manufactured using RP and CNC techniques. Dent Mater. 2013;29:e1-e10.
  25. Loflin WA, English JD, Borders C, Harris LM, Moon A, Holland JN, et al. Effect of print layer height on the assessment of 3D-printed models. Am J Orthod Dentofacial Orthop. 2019;156:283-289. https://doi.org/10.1016/j.ajodo.2019.02.013
  26. Keating AP, Knox J, Bibb R, Zhurov AI. A comparison of plaster, digital and reconstructed study model accuracy. J Orthod. 2008;35:191-201. https://doi.org/10.1179/146531207225022626
  27. Jang Y, Sim JY, Park JK, Kim WC, Kim HY, Kim JH. Accuracy of 3-unit fixed dental prostheses fabricated on 3D-printed casts. J Prosthet Dent. 2020;123:135-142. https://doi.org/10.1016/j.prosdent.2018.11.004
  28. Kirsch C, Ender A, Attin T, Mehl A. Trueness of four different milling procedures used in dental CAD/CAM systems. Clin Oral Investig. 2017;21:551-558. https://doi.org/10.1007/s00784-016-1916-y
  29. McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971;131:107-111. https://doi.org/10.1038/sj.bdj.4802708

Cited by

  1. 3D 프린팅용 광 중합 수지의 두께에 따른 수축 비교 vol.43, pp.1, 2021, https://doi.org/10.14347/jtd.2021.43.1.1