• 제목/요약/키워드: Type of wires

검색결과 174건 처리시간 0.026초

A Study on the Self-Oscillating Mixer

  • Park, K. D.;S. Sakurazawa;H. Arai
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 춘계종합학술대회
    • /
    • pp.132-134
    • /
    • 2000
  • This paper presents self-oscillating mixer(SOM) with simple structure which includes dc source, a cross type groove, and a three terminal GaAsFET. By using parasitic elements such as cooper wires, If level of the active antenna is increased. In order to include active device into FDTD analysis, equivalent voltage source are used to substitute for the active device and to describe the voltage-current relationships. This approach is applied to analyze SOM theoretically.

  • PDF

원형검지기와 기존검지기의 비교 분석에 관한 연구 (A Comparison Between Round Loop and Existing Octagonal Loop Detectors)

  • 장덕명;김영남
    • 대한교통학회지
    • /
    • 제12권4호
    • /
    • pp.35-52
    • /
    • 1994
  • In order to operate the computerized traffic signal system, it requires the detectors which ensure the exact detections of actual traffic data (e.g., traffic volume, occupancy and velocity of vehicles). The octagonal detectors are used currently in Korea. However, the maintenance of the detectors has many problems with the road repairs and the constructions on the pavement, and failure due to the disconnection of the wires. Serious delay due to the long installation time of loops also causes the traffic disturbances. The low sensitivities and splash-over effect can sometimes create error data after installation of the octagonal loops. The mai purpose of this study is to evaluate the feasibility of domestic use of the round (circular) inductive loops which developed recently in U.S.A. It was found that the round loops are comparable to the existing octagonal loops. In addition, the use of the high quality of materials in the round loop system can reduce the current problems and weakpoints of the octagonal loops. The installation cost of the round loop was found out as economic as the octagonal loop. The installation time of the round loop system can be reduced with the specially equipped loop truck, and wide/deep slots without sharp corners can extend the durability without serious stress of loop head wires. In conclusion, the round loop is superior to the octagonal type in overall points. It is recommended that the localization of the materials and equipments of round loop system is required to carry out the extensive local installations. Also, several contractors to meet the nationwide demand should be arranged to gurantee the proper maintenance and operation of the systems.

  • PDF

고전압 초전도 변압기용 연속 디스크 권선의 특성 해석 (Characteristics of a Continuous Disk Winding for High Voltage HTS Transformer)

  • 황영인;이승욱;김우석;최경달
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.295-300
    • /
    • 2007
  • High temperature superconducting (HTS) windings for an HTS transformer which have been developed have two kinds of type, one is the layer winding and the other is disk winding. The layer winding has adopted for an HTS power transformer so far because of the small AC losses of the HTS windings. The disk windings have surface of the HTS wire. We propose a new winding method for a high voltage HTS transformer which has advantages of both type of HTS windings, and we call it continuous disk winding. This new HTS winding consists of pile of HTS disk windings. The continuous disk winding was fabricated with multi-stacked HTS wires for dover HTS transformer. We can check the potential possibility from the characteristic test of the fabricated winding. The new type HTS windings can be applied to HTS power transformers, especially to the high voltage ones.

고속철도 전차선로 고장력 실시간 모니터링 기술 구현 (Implementation Technique of Real-time Monitoring System for High-Speed Rail Contact Wire with High Tension)

  • 조용현;박영;정현진
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1256-1261
    • /
    • 2015
  • Along with the increase of railway catenary system operation speed to 400 km/h, there have been growing demands for good quality current collection systems that satisfy quality standards as well as criteria for safe working. Retaining uniform elasticity tension of contact wires is essential in maintaining high quality contact between pantograph and OCL (Overhead Contact Line) of current collection systems in high speed railways. Therefore, the tension of contact wire must be kept within tight tolerance limits in both working conditions and adverse weather conditions of catenary system. In accordance with these conditions, this paper presents a real time monitoring system for the tensioning device of the newly installed catenary system on the special route of Honam high speed line for 400 km/h operation. For the verification of the true value of tension of contact wires, we have developed ring-type tensioning sensors which were installed on supporting points of mast which compose the catenary system. According to the field test performed on the Honam high speed line catenary system, variation of tension was measured accurately in real-time.

Effect of Ambient Temperature on Insulation Lifetime of Winding Coil Prepared with Polyamideimide/Nanosilica Enamelled Wire

  • Park, Jae-Jun;Woo, Myung-Ha;Lee, Jae-Young;Hwang, Don-Ha
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권5호
    • /
    • pp.297-301
    • /
    • 2016
  • The effects of ambient temperature and diameter on the insulation lifetime of winding coils prepared with polyamideimide (PAI), flexural PAI (nanosilica 5 wt%) and anti-corona PAI (nanosilica 15 wt%) wires were investigated. The winding coils were made of enameled wire with enamel thickness of 30~50 μm. The thickness and width of the rectangular copper wires were 0.77~0.83 mm and 1.17~1.23 mm, respectively. The insulation breakdown lifetime decreased with increasing ambient temperature regardless of wire type and winding coil diameter under an inverter surge of 1.5 kV/20 kHz. The insulation breakdown lifetimes of φ5 mm winding coils at 150, 200, and 250℃ were 11.38, 5.19, and 4.22 min respectively, and those of φ10 mm winding coils at 150, 200, and 250℃ were 11.32, 5.79, and 4.57min respectively. The winding coil diameter had little effect on the insulation lifetime.

350km/h급 고속전차선로 보호선의 선종결정 기법에 관한 연구 (A Study on the Protection Wire Type Decision of Catenary System in the 350km/h High Speed Line)

  • 이학표;서기범;박재영
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1818-1823
    • /
    • 2015
  • In this paper, we analyzed the optimal configuration of protection wire that have been installed in the electric railway power supply system. Protection wires are to suppress the ground potential rise when the short circuit fault between contact wire-rail(C-F), and protect the electronics equipments(signalling and communication) that are facility the wayside. The role of protection wires must be feed back quickly the fault current to the substation when a short circuit fault occurs. In this paper, we proposed that only one line to install the protection wire. Comparing how to newly proposed and existing system, most of the performance is similar. The reason is that most of the current flowing in the protection wire near the location where the fault occurred. There is no problem even if in one line for human safe and the low impedance of the return circuit in dimension to ensure the safety of the facility during the fault. To ensure safety during an fault occurs, it is sufficient even by one line. But, In the protection wire of facilities planning it is necessary to design taking into account the potential utility.

단열양생재 변화 및 열선 전력용량 차이에 따른 슬래브 콘크리트의 온도이력 특성 (Characteristic of Temperature History of Slab concrete by the Change of Insulation Curing Material and Difference of Heated cable Power Capacity.)

  • 정은봉;안상구;정상현;고경택;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.334-336
    • /
    • 2013
  • In this study, the temperature history was evaluated for the improved bubble sheets combining hot wires and PE films, which were developed under the extreme environmental condition of -10℃ and applied on the top surface of slab to prevent initial damage by freezing. Results can be summarized as follows. If improved bubble sheets combining hot wires with different capacity on double and quadruple bubble sheets are used, the temperature history for all materials decreased to 2~3℃ below zero but all test materials except Type 1 secured the accumulative temperature of 45° D·D at 7 days of material age, required for the prevention of initial freezing damage. This indicates the bubble sheets can prevent the initial damage by freezing.

  • PDF

성인의 상완골 과상부 골절의 도수 정복 후 경피적 고정 방식의 치료 결과 (Results of Closed Reduction and Percutaneous Fixation of the Supracondylar Fractures of the Humerus in Adults)

  • 박진수
    • Clinics in Shoulder and Elbow
    • /
    • 제5권2호
    • /
    • pp.102-109
    • /
    • 2002
  • Purpose: To evaluate the results of the treatment of the supracondylar fractures of the humerus according to the fixation methods in adults Materials and Methods: Seven patients, aged 55 to 52 years (average,69 years), were reviewed after a mean follow-up of 37 months (range, 11-65 months). According to AO classification all fractures were classified as type A2 (simple transverse supracondylar fracture). Six patients underwent closed reduction and one patient, open reduction after failure of closed reduction. Percutaneous fixation with cannulated screws was performed to the 4 patients, per- cuta)leous fixation with Kirschner wires in 3 patients. All except one patients have associated medical problems. The results were assessed based on the Mayo Elbow Performance Score. Results: All the patients with cannulated screw fixation had stable bony union with excellent ranges of motion (mean: 5-125 degrees). All the three patients who received percuatnaous smooth K-wire fixation had nonunion with poor results, one of them had changed into cannulated screw. and then had good result. Conclusion: Although simple supracondylar fracture is similar to the pediatric fracture in nature, it should be firmly fixed with the method such as threaded cannualted screw rather than the simple fixation with K-wires.

저온검출기의 열전도 연구 (Heat Flow Studies in Low Temperature Detectors)

  • 김일환;이민규;김용함
    • Progress in Superconductivity
    • /
    • 제12권1호
    • /
    • pp.41-45
    • /
    • 2010
  • Low temperature micro-calorimeters have been employed in the field of high resolution alpha spectrometers. These alpha detectors typically consist of a superconducting or metal absorber and a temperature sensor. The temperature sensor can be a transition edge sensor (TES), a metallic magnetic calorimeter (MMC) or other low temperature detectors for an accurate measurement of temperature change due to an alpha particle absorption. We report a recent study of the heat flow between a replaceable absorber and a temperature sensor. A piece of gold foil in $2.4{\times}2.7{\times}0.03\;mm^3$ is used as an absorber. A $40\;{\mu}m$ diameter Au:Er paramagnetic sensor is attached to another small piece of gold foil in $400{\times}200{\times}30\;{\mu}m^3$ to serve as the temperature sensor. This sensor assembly, Au:Er and gold foil, is placed on a miniature SQUID susceptometer in a gradiometric configuration. The thermal connection between the absorber and the sensor was made with three gold bonding wires. The measured thermal conductance shows a linear dependence to the temperature. The values are in a good agreement with Wiedemann-Franz type thermal conductance of the gold wires.

젤리충전통신케이블의 구리회수를 위한 친환경적 분리기술평가 (Evaluation of Separation on the Copper Recovery from Jelly filled type Cable)

  • 민달기;성일화
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.21-26
    • /
    • 2003
  • The generation of waste cable has been continuously increased as a production of electrical and communication media are extended. The current recovery methods, such as mechanical peeling, incineration, solvent extraction and pyrolysis, seems inadequate because they are either hard to apply in some cases or environmentally unacceptable. It has been shown that copper can be effectively separated from the jelly filled type cables using a soybean oil treatment method. As a result, jelly compound is vanished from the wire by soybean oil bath and waste wires are separated copper and PE by the mechanical chipper. This is a more environmentally friendly method than burning, and considerably faster than Stripping.