Browse > Article
http://dx.doi.org/10.5370/KIEE.2015.64.12.1818

A Study on the Protection Wire Type Decision of Catenary System in the 350km/h High Speed Line  

Lee, Hack-Pyo (Woomin Electric Corporation)
Seo, Ki-Bum (Division of Railroad System Engineering, Woosong University)
Park, Jae-Young (Division of Railroad System Engineering, Woosong University)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.64, no.12, 2015 , pp. 1818-1823 More about this Journal
Abstract
In this paper, we analyzed the optimal configuration of protection wire that have been installed in the electric railway power supply system. Protection wires are to suppress the ground potential rise when the short circuit fault between contact wire-rail(C-F), and protect the electronics equipments(signalling and communication) that are facility the wayside. The role of protection wires must be feed back quickly the fault current to the substation when a short circuit fault occurs. In this paper, we proposed that only one line to install the protection wire. Comparing how to newly proposed and existing system, most of the performance is similar. The reason is that most of the current flowing in the protection wire near the location where the fault occurred. There is no problem even if in one line for human safe and the low impedance of the return circuit in dimension to ensure the safety of the facility during the fault. To ensure safety during an fault occurs, it is sufficient even by one line. But, In the protection wire of facilities planning it is necessary to design taking into account the potential utility.
Keywords
High speed catenary system; Overhead contact lines; Fault protection wire; Current capacity; Mechanical strength;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 S.H Chang, "Technical Considerations Relation to the Protection Wire Type Decision of Catenary System in the High Speed Line", Spring Conference Proceeding of the Korean Society for Railway, 2014. 5
2 S.H Chang, et al., "A Study on the stability of electric railway power feeding system", KRRI, 2001. 12
3 H.B Ryoo, J.O Eim, et al., "Distribution of Fault Current and Potential by Ground Fault Test at the Common Grounding System of the Electric Railway", Spring Conference Proceeding of the Korean Society for Railway, 2012.5
4 H.M Lee, G.D Kim, et al., "Unbalance Analysis on Electric Railway System using PSCAD/EMTDC", ICEE 2005
5 H.M Lee, G.S Jang, et al., "Fault Analysis of AC Electric Railway System using EMTDC", ICEE 2004
6 J. kim, et. al., "Development of Integrated Simulator for AC Traction Power Supply System", Trans. KIEE. Vol 59, No. 1, pp. 76-81, 2010
7 Hansang Lee, Changmu Lee, et al., "A Study for Fault Location Scheme Using the 9-Conductor Modeling of Korean Electric Railway System", Autumn Conference Proceeding of the KIEE, 2006. 11