• 제목/요약/키워드: Two-step adhesives

검색결과 29건 처리시간 0.034초

지각과민억제제 적용이 수종 접착제의 미세인장결합강도에 미치는 영향 (EFFECT OF A DESENSITIZER ON MICROTENSILE BOND STRENGTH OF DIFFERENT ADHESIVES)

  • 황성연;이경하;유미경;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.378-384
    • /
    • 2003
  • This study evaluated the influence of a desensitizer(MS coat) on microtensile bond strength of different adhesives:a three-step adhesive(All-Bond 2), a two-step adhesive(Single Bond), a one-step adhesive(One-up Bond F). Non-caries extracted human molars were used. Dentin surface was obtained by horizontal section on mid-portion of crown using a water-cooled low speed diamond saw. Teeth were randomly divided into 6 group. AMO(MS coat + All Bond), SMO(MS coat + Single Bond)- and OMO(MS coat + One-up Bond F)-dentin surface were treated with 17% EDTA before bonded adhesive. AMX-, SMX- and OMX-dentin surface were bonded with All-Bond 2, Single Bond and One-up Bond F, respectively. with no previous treatment with MS coat and 17% EDTA. About 1cm high resin composite($Z-250^{TM}$) were incrementally build-up on the treated surface. The specimens for the microtensile test were serially sectioned perpendicular to the adhesive layer to obtain $0.7{\times}0.7mm$ sticks. 30 sticks were prepared from each group. After that. tensile bond strength for each stick was measured with Microtensile Tester at a 1mm/min crosshead speed. Fractured dentin surfaces were observed under the SEM. The results were statistically analysed by using a One-way ANOVA and Tukey's test(p<0.05). Value in MPa were: $AMO-44.35{\pm}13.21;{\;}SMO-39.35{\pm}13.32;{\;}OMO-31.07{\pm}10.25;{\;}AMX-49.22{\pm}16.38;{\;}SMX-56.02{\pm}13.35;{\;}OMX-72.93{\pm}16.19$. Application of MS coat reduced microtensile bond strengths of both Single Bond and One-up Bond F, whereas microtensile bond strengths of All-Bond 2 were not affected significantly.

Bovine teeth에 대한 수 종 상아질 접착제의 미세인장결합강도 (MICROTENSILE BOND STRENGTH OF DENTIN BONDING ADHESIVES ON BOVINE TEETH)

  • 송은주;김재문;김신;정태성
    • 대한소아치과학회지
    • /
    • 제34권3호
    • /
    • pp.420-429
    • /
    • 2007
  • 전통적인 3단계 total-etching 시스템인 제 4세대 상아질 접착제로부터 술식의 단순화를 이루며 진화한 제 5, 6세대 및 최근에 소개된 제 7세대 상아질 접착제를 상아질 표면처리방식과 적용단계별로 구분하여 bovine teeth 상아질에 대한 미세인장결합강도를 측정하여 그 효용성을 비교 평가하였다. Bovine incisor의 상아질 표면을 노출시키고, 적절한 표면처리 후 제조사의 지시에 따라 5종의 상아질 접착제; 제 4 세대로 Scotch $Bond^{TM}$ Multipurpose(3M ESPE, USA), $Adper^{TM}$ Single Bond 2(3M ESPE, USA), 제 5세대 $Clearfil^{(R)}$ SE Bond(KURARAY, JAPAN), 제 6세대 AQ $Bond^{TM}$(SUN MEDICAL, JAPAN), 제 7세대 $Clearfil^{(R)}$ tri-S Bond(KURARAY, JAPAN)를 각각 적용하여 미세인장결합강도를 측정하고 접착계면의 파절양상을 관찰하였다. 연구결과 미세인장결합강도는 $Clearfil^{(R)}$ SE Bond군에서 가장 높았으며 다음으로 Scotch $Bond^{TM}$ Multipurpose군, $Adper^{TM}$ Single Bond 2군, AQ $Bond^{TM}$군, $Clearfil^{(R)}$ tri-S Bond군의 순으로 나타났다. 계면의 파절양상은 상대적으로 미세인장강도가 높게 나타난 Scotch $Bond^{TM}$ Multipurpose, $Adper^{TM}$ Single Bond2, $Clearfil^{(R)}$ SE Bond군은 레진의 응집성 파절이 많이 발생하였고 상대적으로 미세인장강도가 낮은 AQ $Bond^{TM}$, $Clearfil^{(R)}$ tri-S Bond 군의 경우에는 대부분 접착성 파절이 관찰되었다. 이상의 결과를 종합하면 상아질 접착제의 미세인장결합강도는 각 접착시스템별로 다소의 차이를 보이며, 특히 제 6, 7세대 상아질 접착제가 이전 세대보다 낮은 것으로 나타났다.

  • PDF

인공타액오염이 유치 상아질에서 3종 상아질 접착제의 결합 강도에 미치는 영향 (Effects of Artificial Saliva Contamination on the Bond Strength of Three Dentin Adhesives to Dentin of Primary Teeth)

  • 배영은;김신;정태성;김지연
    • 대한소아치과학회지
    • /
    • 제44권1호
    • /
    • pp.72-81
    • /
    • 2017
  • 본 연구의 목적은 유치 상아질의 복합레진 술식에서 각 단계별로 치면에 인공타액이 오염되었을 때와 이것을 제거하는 방법이 한 단계 자가부식 접착제와 두 단계 산 부식 접착제의 결합강도에 미치는 영향을 비교 분석하는 것이다. 연구 목적을 달성하기 위해, 건전한 유구치 42개를 선정하여 세 종류의 상아질 접착제인 Scotchbond Universal Adhesive(SBU), All-Bond Universal(ABU)과 Prime & Bond NT(PNT)에 따라 3개의 군으로 분류하였다. 이를 다시 각 접착제에서 7개의 하위 그룹으로 나누었다. 대조군인 1군을 제외한 나머지 군은 인공타액으로 오염시킨 군으로 다음과 같이 분류하였다: 2, 3군 - 접착제 도포 전; 4, 5군 - 접착제 중합 전; 6, 7군 - 접착제 중합 후. 인공타액은 수세, 건조(2, 4, 6군)와 건조(3, 5, 7군)로 제거하였다. 처치된 치면에 복합레진(Filtek, Z-350)으로 수복하고 시편을 제작한 후 미세인장 결합강도(Microtensile bond strength, MTBS)를 측정하였다. One-way ANOVA와 Tukey HSD test를 이용해서 통계분석을 실시하였다(p < 0.05). 대조군에서 MTBS의 평균값은 PNT가 ABU와 SBU에 비해 높게 나타났다(p < 0.001). 세 가지 접착제의 각 오염단계에서 수세와 건조를 시행했을 때(2, 4, 6군)가 건조만 시행했을 때(3, 5, 7군)보다 높은 결합강도를 나타내었다. 그리고 접착제 중합 전 단계에서 인공타액의 오염이 발생했을 때(4, 5군)는 대조군에 비해 낮은 MTBS를 보였다(p < 0.001). 전반적으로 두 단계 산 부식 접착제가 한 단계 자가부식 접착제에 비해 높은 MTBS를 보였다. 접착제를 중합하기 전 단계에서 인공타액에 오염되었을 경우에는 접착 강도가 현저히 감소하였고, 수세와 건조 과정으로 접착강도를 회복할 수 없었다.

Unground enamel에 대한 all-in-one adhesive의 1회 또는 2회 적용이 미세인장 결합강도에 미치는 영향 (Effects of one or two applications of all-in-one adhesive on microtensile bond strength to unground enamel)

  • 손창용;김현철;허복;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제31권6호
    • /
    • pp.445-451
    • /
    • 2006
  • 이 연구에서는 미세인장결합강도 실험과 주사전자현미경을 이용하여 unground enamel에 대한 all-in-one adhesive의 1회 또는 2회 적용에 따른 효과를 평가하였다. 발거된 하악 대구치의 설측 치관부를 사용하여 3개씩 5개의 군으로 분류하였다. SE군은 Clearfil$^{tm}$ SE Bond를 적용하였다. LP1 군, LP2 군은 Adper Prompt L-Pop$^{tm}$을 각각 1회 , 2회 적용하였다. XN1 군, XN2 군은 Xeno$^{R}$III를 각각 1회, 2회 적용하였다. 그런 다음 복합 레진 Z100을 적층 충전하였다. 법랑질 표면의 접착제를 아세톤으로 제거하고 주사 전자 현미경을 이용하여 산 부식 양상을 관찰하였다 미세인장결합강도 측정을 위해 표본을 절단하여 레진과 치아의 접착 계면이 1 mm$^2$이 되도록 하여 실험하였다. 실험의 결과는 One-way ANOVA를 사용해 분석한 다음 Duncan's post-hoc test로 사후 검정 하였다. 본 연구의 결과 all-in-one adhesive의 1회와 2회 적용간에는 유의한 차이가 나타나지 않았으며 two-step self-etching adhesive와 all-in-one adhesive의 산 부식 양상 모두 얕고 불규칙 하였다.

상아질 접착 후 저장기간에 따른 접착제의 접착력 변화 (THE CHANCE OF ADAPTABILITY CHANCE IN ADHESIVE SYSTEMS TO DENTIN SUBSTRTE ACCORDING TO STORAGE TIME)

  • 조영곤;반일환;유미경
    • Restorative Dentistry and Endodontics
    • /
    • 제30권3호
    • /
    • pp.204-214
    • /
    • 2005
  • 본 연구는 상아질에 2단계와 단일 단계 자가 산부식 접착제를 적용하여 복합레진을 접착한 후 저장기간에 따른 미세 인장 결합강도와 접착계면의 변화를 상호 비교하기 위하여 시행하였다. 발거된 상 하악 대구치 48개의 교합면측 상아질을 노출시켜 12개씩 4개의 군으로 분류하였다 사용된 접착제의 종류에 따라 SE Bond 군, AdheSE 군, Adper 군, Xeno III 군으로 분류하여 접착제를 적용한 후, 동일 회사의 복합레진 을 4 mm두께로 접착시켰다. 각 군당 4개의 치아를 선택하여 증류수가 담겨진 용기에 집어넣고 37$^{\circ}C$의 항온기에 각각 1일 15일, 30일 동안 저장한 후 시편을 제작하여 각각 미세인장 결합강도의 측정과 주사전자 현미경 관찰 하여 다음과 같은 결과를 나타내었다. 2단계 자가 산부식 접착제는 1일에서 30간의 저장기간 동안 결합강도가 점차적으로 감소하였지만 통계학적으로 유의한 차이를 나타내지 않았고, 상아질과 접착제 간에 긴밀한 접착관계를 보였다. 반면에 단일 단계자가 산부식 접착제는 1일의 저장기간에 비해 30일의 저장기간에서 통계학적인 결합강도의 감소를 나타내었으며, 상아질과 접착제 간에 넓은 간극이 관찰되었다. 따라서 본 연구에서 나타난 두 종류의 30일 동안의 접착내구성은 2단계 자가 산부식 접착제가 단일 단계 자가 산부식 접착제보다 우수한 것으로 나타났다.

Effect of Multi-functional Group of Acrylate Crosslinker on Properties of Waterborne Polyurethane-acrylate

  • Moon, Seok Kyu;Kim, Eun-jin;Kwon, Yong Rok;Kim, Jung Soo;Kim, Hae Chan;Park, Han Soo;Kim, Dong Hyun
    • Elastomers and Composites
    • /
    • 제57권3호
    • /
    • pp.100-106
    • /
    • 2022
  • Waterborne polyurethane-acrylate(WPUA) dispersions were prepared by surfactant-free emulsion polymerization in a two-step process. In the first step, polytetrahydrofuran, isophorone diisocyanate, dimethylol proponic acid, and 2-hydroxyethyl methacrylate were used to synthesize a vinyl-terminated polyurethane prepolymer. In the second step, styrene, methyl methacrylate, butyl acrylate, and different multi-functional crosslinkers were copolymerized. 1,6-hexanediol diacrylate, trimethylolpropane triacrylate, and pentaerythritol tetraacrylate were used as the crosslinkers, and their effect on the mechanical and thermal properties of WPUA was investigated. Overall, as the number of functional groups of the cross-linker increased, the gel fraction improved to 79.26%, the particle size increased from 75.9 nm to 148.7 nm, and the tensile strength was improved from 5.86 MPa to 12.40 MPa. In thermal properties, the glass transition temperature and decomposition temperature increased by 9.9℃ and 18℃, respectively. The chemical structures of the WPUA dispersions were characterized by Fourier-transform infrared spectroscopy. The synthesized WPUA has high potential for applications such as coatings, leather coatings, adhesives, and wood finishing.

접착시스템의 종류에 따른 유동성 레진과 법랑질의 미세전단 결합강도 (Microshear bond strength of a flowable resin to enamel according to the different adhesive systems)

  • 김정호;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제36권1호
    • /
    • pp.50-58
    • /
    • 2011
  • 연구목적: 이 연구는 2종의 전부식 접착제와 4종의 자가부식 접착제를 이용하여 유동성 레진을 법랑질에 접착할 경우, 접착제에 따른 미세전단 결합강도와 파절양상을 비교하기 위하여 시행하였다. 연구 재료 및 방법: 발거된 60개의 대구치 치관의 법랑질을 이용하였고, 사용된 접착시스템의 종류에 따라 6개의 군; OS 군(One-Step), SB 군(Single Bond), SE 군(Clearfil SE Bond), TY 군(Tyrian SPE와 One-Step Plus), AP 군(Adper prompt L-Pop), GB 군(G-Bond)으로 분류하였다. 각 군의 법랑질 표면에 배정된 접착시스템을 적용한 후, Tygon tube를 이용하여 법랑질 표면에 유동성 레진(Filtek Z 350 flowable resin)을 접착하였다. 각 군의 미세전단 결합강도를 측정한 후 주사전자현미경하에서 파절양상을 비교하였다. 결과: 1. SB 군의 결합강도는 다른 모든 군보다 통계학적으로 높게 나타났고, GB 군의 결합강도는 다른 모든 군의 결합강도 보다 통계학적으로 낮게 나타났다(p < 0.05). 2. OS 군과 SE 군 및 AP 군의 결합강도는 SB 군보다 낮게 나타났지만, TY 군과 GB 군보다 통계학적으로 높게 나타났다(p < 0.05). 3. TY 군의 결합강도는 GB 군보다 통계학적으로 높게 나타났다(p < 0.05). 4. 접착성 파절은 TY 군과 GB 군에서 가장 많이 나타났고, 혼합파절은 SB 군과 SE 군에서 가장 많이 나타났으며, 응집성 파절은 OS 군, SB 군, SE 군 및 AP 군에서 각각 1개씩 나타났다. 결론: 접착 단계가 같은 접착시스템이라 해도 법랑질에 대한 유동성 레진의 미세전단 결합강도는 서로 다르게 나타났다.

Effect of dimethyl sulfoxide on bond durability of fiber posts cemented with etch-and-rinse adhesives

  • Shafiei, Fereshteh;Memarpour, Mahtab;Sarafraz, Zahra
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.251-258
    • /
    • 2016
  • PURPOSE. This study was undertaken to investigate whether use of an adhesive penetration enhancer, dimethyl sulfoxide (DMSO), improves bond stability of fiber posts to root dentin using two two-step etch-and-rinse resin cements. MATERIALS AND METHODS. Forty human maxillary central incisor roots were randomly divided into 4 groups after endodontic treatment and post space preparation, based on the fiber post/cement used with and without DMSO pretreatment. Acid-etched root dentin was treated with 5% DMSO aqueous solution for 60 seconds or with distilled water (control) prior to the application of Excite DSC/Variolink II or One-Step Plus/Duolink for post cementation. After micro-slicing the bonded root dentin, push-out bond strength (P-OBS) test was performed immediately or after 1-year of water storage in each group. Data were analyzed using three-way ANOVA and Student's t-test (${\alpha}$=.05). RESULTS. A significant effect of time, DMSO treatment, and treatment${\times}$time interaction were observed (P<.001). DMSO did not affect immediate bonding of the two cements. Aging significantly reduced P-OBS in control groups (P<.001), while in DMSO-treated groups, no difference in P-OBS was observed after aging (P>.05). CONCLUSION. DMSO-wet bonding might be a beneficial method in preserving the stability of resin-dentin bond strength over time when fiber post is cemented with the tested etch-and-rinse adhesive cements.

자가 중합 복합 레진과 두 단계 산 부식 접착제의 친화성에 대한 중간 접착제와 흐름성 레진의 효과 (EFFECT OF AN INTERMEDIATE BONDING RESIN AND FLOWABLE RESIN ON THE COMPATIBILITY OF TWO-STEP TOTAL ETCHING ADHESIVES WITH A SELF-CURING COMPOSITE RESIN)

  • 최속경;염지완;김현철;허복;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.397-405
    • /
    • 2009
  • 이 연구의 목적은 자가 중합복합 레진과 두 단계 산 부식 접착제의 친화성에 대한 중간 접착제와흐름성 레진의 효과를 미세 인장 결합 강도를 통해 비교하는 것이었다. 20개의 발거된 대구치를 사용해 접착제와 부가적인 적용(활성제, 중간 접착제, 흐름성 레진)에 따라 XP bond 그룹 (XA, XB, XF 그룹), Prime & Bond NT 그룹 (NA, NB, NF 그룹), Optibond solo plus 그룹 (OA, OB OX 그룹)으로 나누었다. 접착제 적용 후 활성제, 중간 접착제, 흐름성 레진을 각각 적용하고 상부에 자가 중합 레진을 축성하였다. 24시간 동안 실온의 증류수에 보관 후 각 그룹당 10개의 시편을 준비하였다. 모든 시편의 미세인장 결합 강도를 측정하여 다음과 같은 결과를 얻었다. 1. 모든 그룹에서 중간 접착제와 흐름성 레진의 적용은 활성제 적용보다 더 높은 결합 강도를 보였다. 2. 선택된 방법에 관계없이, Optibond solo plus 그룹은 가장 낮은 미세인장 결합강도를 보였다. 3. 파절 양상은 대부분 접착성 파절을 보였고 일부 레진 내에서 응집성 파절을 보였다. 이번 연구의 결과로부터, 중간 접착제와 흐름성 레진의 적용이 낮은 pH를 가지는 두 단계 산 부식 접착제와 자가 중합복합 레진의 상아질 접착에 더 효과적이라 예상된다.

최근 소개된 상아질 접착제의 전단 접착 강도 비교 (An Evaluation of Shear Bond Strength of New Dentin Bonding Agents)

  • 신지선;황은지;김종빈
    • 대한소아치과학회지
    • /
    • 제44권3호
    • /
    • pp.358-364
    • /
    • 2017
  • 소아치과 영역에서 수복 치료에 널리 쓰이는 레진 치료의 술식 민감성 및 시간 감소에 대한 꾸준한 노력으로 새로운 접착제의 개발이 이루어지고 있는데 최근 출시된 접착제와 기존에 널리 쓰이는 두 단계 접착제와 비교 분석하여 임상적으로 적용하기에 어떠할지 평가해 보고자 하였다. 본 연구에서는 78개의 건전한 소구치를 3군으로 나누어 순면 법랑질에 새로 개발된 $Tetric^{(R)}$ N-Bond Universal (Ivoclar Vivadent, Liechtenstein)과 $GC^{(R)}$ G-Premio BOND (GC Co., Japan)를 실험군으로 하고 기존의 5세대 $3M^{TM}$ Single Bond2 (3M ESPE, USA)를 대조군으로 설정하여 동일하게 $Filtek^{TM}$ Z-350 (3M ESPE, USA)복합 레진을 접착시킨 후 접착제에 따른 전단접착강도를 비교 평가하였다. 그 결과 산부식 과정을 따로 적용하지 않은 두 실험군에서 각각의 전단접착강도가 산부식 과정을 포함한 대조군의 결과보다 통계학적으로 유의성 있게 낮은 결과를 나타내었다. 또한 새로 개발된 두 접착제간 비교에서는 $Tetric^{(R)}$ N-Bond Universal 제품이 $GC^{(R)}$ G-Premio BOND 제품보다 전단 접착 강도가 유의성 있게 큰 것으로 나타나 임상에서 제품을 선택할 때 참조할 수 있을 것으로 생각된다.