• Title/Summary/Keyword: Two transformer

Search Result 556, Processing Time 0.032 seconds

Design of PCB Embedded Balanced-to-unbalanced WiMax Duplexer Using Coupled LC Resonators (WiMAX 응용을 위한 결합 공진기 기반의 PCB 내장형 평형신호 듀플렉서의 설계)

  • Park, Ju-Y.;Park, Jong-C.;Park, Jae-Y.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1587_1588
    • /
    • 2009
  • In this paper, PCB embedded balanced-to-unbalamced duplexer using coupled LC resonator was introduced for low cost dualband WiMax front-end-module application. In order to obtain the function of bandpass filter and balun transformer, proposed duplexer was configured by using magnetically coupled LC resonator. Out-of-band suppression was enhanced by applying two m-Derived transform circuits to obtain transmission zeros at 2GHz and 4.8GHz. In order to reduce the size of embedded duplexer, BaSrTiO3 (BST) composite high Dk RCC film was applied to improve the capacitance density. This high Dk film provided the capacitance density of 12.2 pF/mm2. The simulation results shows that fabricated duplexer had an insertion loss of 2.9dB and 5.5dB and return loss of 15dB and 16dB for 2.5GHz~2.6GHz and 3.5GHz~3.6GHz, respectively. The maximum magnitude and phase imbalance were 0.01dB and 0.17dB, and 1degree and 2degree in its passband, respectively. The out-of-band suppression was observed approximately 29dB and 40dB below 1.9GHz and over 4.5GHz, respectively. It has a volume of 6 mm $\times$ 7 mm $\times$ 0.7 mm (height).

  • PDF

The Study of the Characteristics on Water Treatment Using Hybrid Water Plasma Torch (하이브리드 수중 플라즈마 토치를 이용한 수처리 특성연구)

  • Kwon, Soon-Kurl;Lee, Su-Ho;Cho, Man-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.138-143
    • /
    • 2006
  • This research emphasis the commercialize and experiment in the quality of water treatment by making water treatment reactor. The hybrid water plasma torch used this research is excellent in tans of economical efficiency because of using existent neon transformer. Further more, It has excellent energy efficiency because it is manufactured by low electric power. Especially hybrid water plasma torch used this research has two filed of water plasma and inputs each strong point into the water. Following The data such as dissolved ozone(2.8[ppm]), hydrogen peroxide(100[ppm]), 2[PH], are very affordable data and immensely useful in sterilization. Those data have excellent result: perfect eradication of a colon bacillus within maximum 10 minute applying to sterilization processing of a colon bacillus.

Fusing Time Characteristics Analysis of Cable according to Temperature and Insulator (온도 및 절연체에 따른 케이블의 단선시간 특성 해석)

  • Kim, Ju-Hee;Kang, Sin-Dong;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.15-20
    • /
    • 2018
  • This paper describes the fusing time characteristics of Light PVC Sheathed Circular Cord(VCTF) and Tray Frame Retardant(TFR) cables according to increased temperature under over current condition. The experimental equation will be used to determine the validity and reliability of the test results. The over current flowed 3, 5 and 10 times higher than the amount of allowable current using DC power supply with DAQ(Data Acquisition) measurement system. An infrared radiation heater, which was controlled by a variable AC auto transformer, was used to increase the temperature from room temperature to 50, 100 and 150 degrees Celsius. First, two type of cables were analyzed those with different cross-sectional areas with in the same structure and those with different structures with in the same cross-sectional areas. Then, it was determined how fusing time had been influenced according to the cross-sectional areas and different structures, respectively. The cable resistance was increased by joule heating according to increasing temperature. Therefore, the allowable current of cable is decreased. Finally, the fusing time of the cable was decreased due to increased temperatures at current flow, which were 3 times the amount of allowable current. The instantaneous breakdown was observed when current flow was 5 and 10 times over the amount of allowable current. The fusing time is directly affected by the structure of cable insulation.

Dynamic Analysis and Control Loop Design of ZVS-FB PWM DC/DC Converter (ZVS-FB PWM DC/DC 변환기의 동특성 해석 및 제어기 설계)

  • 이득기;윤길문;차영길;김흥근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.231-239
    • /
    • 1998
  • This paper presents the dynamic analysis and control loop design of a zero voltage switching full bridge (ZVS-FB) PWM DC/DC converter. The small-signal model is derived incorporating the effects of phase shift control and the utilization of transformer leakage inductance and power FET junction capacitance to achieve zero voltage resonant switching. These effects are modeled by introducing additional feedforward and feedback terms for duty cycle modulation. Based on the results of the small-signal analysis, the control loop is designed using a simple two-pole one-zero compensation circuit. To show the validity of the design procedures, the small signal analysis of the closed loop system is carried out and the potential of the zero voltage switching and the superiority of the dynamic characteristics are verified through the experiment with a 2 kW prototype converter.

  • PDF

Design and Application of PFC Direct Drive Inverter for LCD-TV (LCD-TV용 PFC Direct 구동 인버터의 설계와 응용)

  • Ko, Tae-Seok;Jung, Yong-Joon;Hong, Sung-Soo;Han, Sang-Kyu;Jang, Byung-Jun;Jang, Young-Su;Han, Seung-Ho;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • The conventional CCFL (Cold Cathode Fluorescent Lamp) inverter used in the backlight unit for LCD-TV, composed of the three power stage, can degrade the whole power conversion efficiency. In this paper, a novel scheme to drive the CCFL, composed only of the two power stage without using a dc/dc power stage, is proposed to enhance the whole power conversion efficiency. By adopting the proposed "4-in-1 Transformer", the current balance and the simultaneous ignition among the four CCFL lamp are assured with the one inverter circuit. The proposed scheme features the simple circuit structure, which can save the volume and the cost in the LCD backlight unit. Design considerations are discussed and design procedures are derived. Experimental results of the proposed scheme for 40" LCD-TV are presented to confirm the theoretical analysis.

A Study on Future System Construction Using WSCR Strengthness Index based on Python (Python 기반 WSCR 강건 지수를 이용한 미래계통 구축에 관한 연구)

  • Park, Seong-Jun;Hur, Jin;Kim, Hyun-Jin;Cho, Yoon-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.994-1001
    • /
    • 2018
  • In this paper, to studied about future power system construction using PSS / E-Python API. Python-based future system automatical construction methods and modeling of renewable sources. it confirmed the stability of the powert system for each renewable area by calculating the weighted short circuit ratio (WSCR) index. it calculated the short circuit ratio (SCR) and selected the transmission line linkage scenario to improve the stability of vulnerable areas. it confirmed the WSCR index improvement through the selected transmission line linkage of scenario, and analyzed the stability of the renewable power system applying the scenario. It describes Facts and Shunt devices adjustment for the load flow convergence. It describes the stable methed of the bus voltage through the transformer Ratio Tap adjustment. By performing PSS/E ASCC using the Python it was performed three-phase short circuit fault capacity analysis, it is confirmed whether excess of the fault current circuit breaker capacity. In order to contingency accident analysis, it have described the generation of one or two line list of each areas using the Python. The list is used to contingency analysis and describe the soluted of the transmission line overload through comparison before and after adding the scenario line.

Implementation of Various FIR Filters using Constrained Least Square Criterion (제한된 최소 자승 오차 기준에 의한 다양한 FIR 필터 구현)

  • Hong, Seung-Eok;Kim, Joong-Kyu
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.175-185
    • /
    • 1998
  • In this paper, we studied some design methodologies of typical FIR filters based on the peak-error constrained least square criterion which was first introducedd by Adams in 1991. This method is a mixed type of the classical least squared error method(LSM) and the so-called min-max error method (MMM). And by considering both the least squared error as well as the maximum error, the solution, i.e. the impulse response of the filter, can be found only when the restrictions on maximum gain, transition bandwidth, and the squared error are satisfied simultaneously under some trade-off conditions. We used the multiple exchange algorithms for optimization procedure and applied the design methodology to the cases of the multiband filter, the differentiator, and the Hilbert transformer by taking the balance of two design criteria into account. The results show that the peak-error constrained least weighted square error design method(PLEM) is superior in performance to the existing LSM and MMM from both the squared error and the maximum error standpoints. And it is verified that PLEM can be applied to not only the case of simple low pass filter, but also to various types of FIR filters.

  • PDF

Performance Characteristics of Type II LiBr-H2O Absorption Heat Pump in Accordance with the Refrigerant Heat Exchanger Configuration (냉매 열교환기 구성방법에 따른 제 2종 흡수식 히트펌프의 성능 특성 변화에 관한 연구)

  • Lee, Chang Hyun;Yoon, Jun Seong;Kim, In Gwan;Kwon, Oh Kyung;Cha, Dong An;Bae, Kyung Jin;Kim, Min Su;Park, Chan Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.7
    • /
    • pp.373-384
    • /
    • 2017
  • The objective of this study was to determine the effect of refrigerant heat exchanger on the performance of type II absorption heat pump performance using numerical analysis. Two heat exchange installation methods were used: solution to refrigerant and waste hot water to refrigerant. These methods were compared to the standard model of hot water flow without using refrigerant heat exchanger. When waste hot waters were bypassed to refrigerant heat exchanger, COP was not affected. However, steam mass generation rates were increased compared to those of the standard model. When solutions were bypassed to the refrigerant heat exchanger, results were different depending on the place where the solution rejoined. COP and steam mass generation rates were lower compared to those when waste heat water was passed to refrigerant heat exchanger. Thus, it is possible to obtain higher steam mass generation rates by using waste water and installing refrigerant heat exchanger.

Wideband horn antenna including circular-polarizer and straight-type mode-converter for Ka-band (Ka-대역 원형 편파기와 직선구조 모드 변환기를 포함한 광대역 혼 안테나)

  • Jung, Young-Bae
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.299-304
    • /
    • 2011
  • In this paper, the circular polarized horn antenna composed of circular polarizer and impedance transformer is designed, and fabricated. For the circular polarizer, two types of the polarizer are designed and the electrical performance of them is compared; rectangular waveguide polarizer with $45^{\circ}$-inclined dielectric slab and oval shaped one. Straight type mode converter has a stepped impedance structure and plays a role of converting waveguide TE mode into coaxial TEM mode, and the proposed antenna is designed to directly connect with active components using the feed-through in the input port of the mode converter. Fabricated antenna has the wideband performance, VSWR<1.5 and Axial ratio < 1.0dB, ranging from 30.085 to 30.885 GHz, and the antenna gain is 6.7~7.0 dBi.

Study on the Magnetic Shield Effect of Carbon-based Materials at Extremely Low Frequency (탄소계 소재를 이용한 극저주파 영역에서의 자기 차폐효과 연구)

  • Oh, Seong Moon;Kang, Dong Su;Lee, Sang Min;Baek, Un Gyeong;Roh, Jae Seung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • To examine the magnetic shielding effect for carbon-based materials at extremely low frequencies (60 Hz), two types of carbon black (Super-P and Denka Black) and a natural graphite (HC-198) were mixed into organic binder at 10 wt.% to produce a coating solution, and a powder coating with varying thickness was applied on an aluminum disk measuring 88 mm in radius. A device was developed to measure the sheielding effect at extremely low frequencies. A closed circuit was achieved by connecting a transformer and a resistor. The applied voltage was fixed at 65 V, and the magnetic field was measured to being the range of 4.95~5.10 mG. Depending on the thickness of the coating layer, the magnetic field showed a decreasing trend. The maximum decrease in the magnetic field of 38.3% was measured when natural graphite was coated with specimens averaging $455{\mu}m$. This study confirmed that carbon-based materials enable magnetic shielding at extremely low frequencies, and that the magnetic shielding effect can be enhanced by varying the coating thickness.