Abstract
The conventional CCFL (Cold Cathode Fluorescent Lamp) inverter used in the backlight unit for LCD-TV, composed of the three power stage, can degrade the whole power conversion efficiency. In this paper, a novel scheme to drive the CCFL, composed only of the two power stage without using a dc/dc power stage, is proposed to enhance the whole power conversion efficiency. By adopting the proposed "4-in-1 Transformer", the current balance and the simultaneous ignition among the four CCFL lamp are assured with the one inverter circuit. The proposed scheme features the simple circuit structure, which can save the volume and the cost in the LCD backlight unit. Design considerations are discussed and design procedures are derived. Experimental results of the proposed scheme for 40" LCD-TV are presented to confirm the theoretical analysis.
기존의 LCD-TV의 백라이트 모듈로 사용되는 CCFL(Cold Cathode fluorescent Lamp:냉 음극형 형광램프)을 구동 하는 인버터 회로는 3단으로 구성되어 전체 시스템의 효율저하 문제가 발생한다. 본 논문에서 제안된 회로는 DC/DC단을 사용하지 않아 전체 시스템의 효율을 향상 시킬 수 있다. 역률 개선을 위한 PFC(Power Factor Corrector)단의 출력 전압을 인버터의 입력전압으로 사용하여 CCFL을 구동한다. 인버터에서는 4-in-1트랜스포머를 사용하여 CCFL간의 전류평형 및 동시점등을 이룰 수 있으며, 전류평형을 위한 부가회로가 불필요하다. 인버터 시스템을 2단으로 구성하여 회로구성이 간소화되고 회로의 부피 및 제작 원가를 저감 할 수 있다. 제안된 기준에 따라 설계한 인버터를 40인치 LCD-TV용 백라이트 모듈에 적용한 실험결과를 통해 유용성을 검증한다.