• Title/Summary/Keyword: Triple Controlled Type

Search Result 7, Processing Time 0.026 seconds

Applications of Triple Controlled Type DDFS-driven PLL Frequency Synthesizer to Broadband Wireless Systems (3중조절 DDFS 구동 PLL 주파수 합성기의 광대역 무선 통신시스템에 응용)

  • Heung-Gyoon Ryu;Byeong-Rok An
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.6
    • /
    • pp.546-551
    • /
    • 2002
  • In this paper, a triple controlled type DDFS-driven PLL frequency synthesizer with reduced complexity is used to show its applications for broadband wireless communication systems by frequency synthesis control. Since the proposed DDFS-driven PLL synthesizer is very simplified to use only phase accumulator in DDFS, it improves the switching speed and power consumption than the conventional DDFS-driven PLL frequency synthesizer. It is appropriate for applications with requirements of broadband, low-power consumption and high switching speed, since the proposed synthesizer can cover a wide range of frequency bands by the triple frequency control parameters. Method and results of frequency control parameters assignment are shown for the several frequency bands applications such as GSM, IMT-2000, Bluetooth and PCS system.

A Study on the novel Nano ESD Protection Circuit with High Speed and Low Voltage (새로운 구조의 나노소자기반 고속/저전압 ESD 보호회로에 대한 연구)

  • Lee, Jo-Woon;Yuk, Seung-Bum;Koo, Yong-Seo;Kim, Kui-Dong;Kwon, Jong-Ki
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.589-590
    • /
    • 2006
  • A novel Triple-Well P-type Triggered Silicon Controlled Rectifier (TWPTSCR) for on-chip ESD protection implemented with a triple-well CMOS technology is presented. Unlike conventional SCR devices, the proposed TWPTSCR offers a reduced triggering voltage level as well as the enhanced ESD performance of the SCR devices. From the experimental results, the TWPTSCR with a device width of 20um has the triggering voltage of 1.1V.

  • PDF

Study on Optimal Working Conditions for Picking Head of Self-Propelled Pepper Harvester by Factorial Test

  • Kang, Kyung-Sik;Park, Hoon-Sang;Park, Seung-Je;Kang, Young-Sun;Kim, Dae-Cheol
    • Journal of Biosystems Engineering
    • /
    • v.41 no.1
    • /
    • pp.12-20
    • /
    • 2016
  • Purpose: Pepper prices have risen continuously because of a decrease in cultivation area; therefore, mechanical harvesting systems for peppers should be developed to reduce cost, time, and labor during harvest. In this study, a screw type picking head for a self-propelled pepper harvester was developed, and the optimal working conditions were evaluated considering helix types, winding directions of helix, and rotational speeds of the helix. Methods: The screw type was selected for the picking head after analyzing previous studies, and the device consisted of helices and a feed chain mechanism for conveying pepper branches. A double helix and a triple helix were manufactured, and rotational speeds of 200, 300, and 400 rpm were tested. The device was controlled by a variable speed (VS) motor and an inverter. Both the forward and reverse directions were tested for the winding and rotating directions of the helix. An experiment crop (cultivar: Longgreenmat) was cultivated in a plastic greenhouse. The test results were analyzed using the SAS program with ANOVA to examine the relationship between each factor and the performance of the picking head. Results: The results of the double and triple helix tests in the reverse direction showed gross harvest efficiency levels of 60-95%, mechanical damage rates of 8-20%, and net marketable portion rates of 50-80%. The dividing ratio was highest at a rotational speed of 400 rpm. Gross harvest efficiency was influenced by the types of helix and rotational speed. Net marketable portion was influenced by rotational speed but not influenced by the type of helix. Mechanical damage was not influenced by the type of helix or rotational speed. Conclusions: Best gross harvest efficiency was obtained at a rotational speed of 400 rpm; however, operating the device at that speed resulted in vibration, which should be reduced.

Fabrication of Depth-probe type Silicon Microelectrode array for Neural signal Recording (신경신호기록용 탐침형 반도체 미세전극 어레이의 제작)

  • Yoon, T.H.;Hwang, E.J.;Shin, D.Y.;Kim, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.147-148
    • /
    • 1998
  • In this paper, we developed the process for depth-probe type silicon microelectrode arrays. The process consists of four mask steps only. The steps are for defining sites, windows, and for shaping probe using plasma etch from above, and for shaping using wet etch from below, respectively. The probe thickness is controlled by dry etching, not by impurity diffusion. We used gold electrodes with a triple dielectric system consisting of oxide/nitride/oxide. The shank of the probe taper from 200um to tens of urn tip and has 30 um thickness.

  • PDF

A Study on the Injection Characteristics of a Piezo Injector for Controlling Accurate Multiple Injection (커먼레일 타입 피에조 인젝터의 정밀 다단분사 제어를 위한 분사특성 연구)

  • Park, Heebum;Kim, Hyungik;Park, Sangki;Lee, Kihyung
    • Journal of ILASS-Korea
    • /
    • v.18 no.4
    • /
    • pp.176-181
    • /
    • 2013
  • In this study, injection quantity, rate and spray image of multiple injections which are important design parameters for a piezo type injector have been investigated. Interval of injections and a number of injections in multiple injection strategy has been controlled to verify interaction of each injection. Spray characteristics of multiple injections have been researched through optical process with a high speed camera in a high pressure chamber. In addition, a method of RMS(Root Mean Square) process has been used for comprehending the distribution of injection easily. As a result, in case of piezo type injector, characteristics of injection quantity according to charging voltage and the difference of injection quantity between single and triple injection were confirmed. Also, injection rate for increasing injection duration was confirmed. And spray characteristics of multiple injections were improved; multiple injections were possible in a shorter time interval between each injection. With this study, a possibilities of more accurate multiple injection control would be expected.

Analysis of Soil Samples Obtained from Piston Sampler and Large Diameter Sampler (피스톤 샘플러와 대구경 샘플러를 이용한 시료 샘플의 공학적 분석)

  • Kim, Young Chin;Kang, Jae Mo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.29-34
    • /
    • 2008
  • A large diameter sampler was developed to take undisturbed samples from not only soft ground but also sandy and weathered ground. The large diameter sampler which was developed in Korea Institute of Construction Technology(KICT-type large diameter sampler) was manufactured based on the principle of triple core barrel sampling. A specially designed cutting device was used to cut and contain various kinds of samples in the sampler during a sampling and retrieval procedure. By adjusting the stiffness of the spring located at the top of the sampler, the distance between the cutting shoe and auger can be controlled in accordance with the ground condition. In order to investigate the applicability of the developed sampler and compare the quality of the samples taken by the sampler with that by the traditional thin-walled tube sampler, samples were taken at various sites according to the ground condition. And a series of laboratory tests such as the unconfined compress ion test, triaxial compression test, oedometer test, large diameter Rowe cell consolidation test (D: 150 mm) were performed. The test results showed that the samples by the KICT-type large diameter sampler show higher quality than the samples by the thin-walled tube sampler. And the validity and applicability of the developed KICT-type large diameter sampler was confirmed accordingly.

  • PDF

Effect of Glucose Control, SDSCA and Quality of Life of D-chiro-inositol(DCI) in patients with type 2 diabetes: A Path Analysis (제2형 당뇨병 환자의 D-chiro-inositol의 혈당강하 효과와 당뇨 자가관리 및 삶의 질: 경로분석)

  • Kang, Young Mi;Kim, Hyun Jin;Lee, Tae-Yong;Ku, Bon-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.243-253
    • /
    • 2018
  • This study aimed to investigate the effects of DCI on glucose control, quality of life(SF-36 Version 2.0, Korean) and SDSCA(Summary of Diabetes Self-Care Activities) in patients with type 2 diabetes mellitus. A randomized, double-blind, placebo-controlled study was performed on 46 patients with HbA1c 7.0% taking triple anti-diabetic drug regimen who visited the department of Endocrinology and Metabolism in Chungnam National University Hospital between March 2015 and May 2016. As a result, DCI treatment in the intervention group resulted in significantly reduced HbA1c levels $8.75{\pm}0.79%$(baseline), $8.36{\pm}1.03%$(after 12weeks), and $8.65{\pm}0.81%$(after 24weeks). However, patients in the control group did not show any significant change. Interestingly, both DCI treatment group and the control group significantly showed improvements in SDSCA. Participants in the intervention group showed a small yet significant improvement in their only fasting blood glucose test in SDSCA and revealed significant increase in the quantitative levels of quality of life, from $73.05{\pm}16.85$ to $82.74{\pm}10.68$. By using pathway analysis, improvement of SDSCA scores(${\beta}=-0.505$, t=-2.743) was the most influential factor to the fasting blood glucose. The quality of life of patients with type 2 diabetes mellitus was affected by changes of SDSCA scores(${\beta}=0.411$, t=2.024) and fasting c-peptide(${\beta}=-0.445$, t=-2.668) in DCI treatment group. In conclusion, treatment of DCI effectively improved glucose control in patients with type 2 DM(HbA1c level>7.0%) after 12 weeks of treatment, although it had no impact on glucose control after 24 weeks of treatment. Improved glucose control may encourage diabetic patients to conduct self-care activities and improve the quality of life. Based on the present study, we suggest that diabetes self-management, as well as consideration of comprehensive laboratory findings, may be important factor in regulating the quality of life in type 2 DM patients.