• 제목/요약/키워드: Transverse magnification

검색결과 16건 처리시간 0.025초

Determination of Transverse Magnifications by Distortion Analysis

  • Lee, Sukmock;Kim, Byungoh
    • Journal of the Optical Society of Korea
    • /
    • 제17권2호
    • /
    • pp.136-141
    • /
    • 2013
  • A method to determine the transverse magnification (TM) of an imaging system is discussed. This method is different in that TM can be determined accurately by using distortion analysis. We demonstrate the validity of the method via numerical simulation with accompanying experimental data for a thick bi-convex lens.

파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향 : 전후방 및 좌우 이동 (Effect of Head Positioning in Panoramic Radiography on the Vertical and Horizontal Magnification : Displacement along the Sagittal and Transverse Plane)

  • 김용건;이영균;안서영
    • 구강회복응용과학지
    • /
    • 제29권3호
    • /
    • pp.249-258
    • /
    • 2013
  • 이 연구의 목적은 환자의 머리 위치에 따른 파노라마방사선사진의 수평 및 수직 확대율을 비교 평가하는 것이었다. 직경 4 mm인 금속구를 건조 두개골의 하악 전치부와 우측 대구치부의 치조골 상방에 위치시켰다. 수평 및 수직적 위치의 변화를 재현하기 위해 수직, 수평 이동량을 조절할 수 있는 두개골 고정장치를 이용하여, 전방, 후방, 좌측 및 우측으로 이동시킨 후 파노라마방사선사진을 OP-100D를 이용하여 획득하였다. 촬영된 영상은 DICOM 형식으로 저장되었고, INFINITT PACS software를 이용하여 금속구의 폭과 높이의 평균값을 구하였다. 적절한 위치에서 촬영된 파노라마방사선사진에서 금속구의 수평 확대율은 1.224-1.439였고, 수직 확대율은 1.286-1.345였다. 건조 두개골의 위치 변화에 따른 수평 확대율은 0.798-6.297로 통계적으로 유의한 차이를 보인 반면(P<0.05), 수직 확대율은 1.245-1.418 정도로 수평 확대율에 비해 차이를 보이지 않았다.

파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향: 상하 및 좌우회전 (Effect of head positioning on the vertical and horizontal magnification in panoramic radiographs: rotation along the sagittal and transverse plane)

  • 김용건;변진석;안서영
    • 구강회복응용과학지
    • /
    • 제30권1호
    • /
    • pp.1-8
    • /
    • 2014
  • 목적: 이 연구는 파노라마방사선사진 촬영 시 환자의 머리 위치가 상방, 하방, 좌측 및 우측으로 회전됨에 따른 수평 및 수직 확대율의 변화를 비교 평가하는 것이었다. 연구 재료 및 방법: 직경 4 mm인 금속구 5개를 건조 두개골의 하악 전치부(2개)와 우측 대구치부(3개)의 치조골 상방에 위치시켰다. 상하 및 좌우 회전량을 조절할 수 있는 두개골 고정장치에 건조 두개골을 고정시킨 후, 기준 위치와 회전된 위치에서 파노라마방사선사진을 쵤영하였다. 결과: 기준 위치에서 평균 수평 확대율은 $1.22{\pm}0.01-1.44{\pm}0.01$이었고, 평균 수직 확대율은 $1.29{\pm}0.00-1.35{\pm}0.02$였다. 전치부와 구치부 비교시 수평 확대율은 전치부에서 $1.24{\pm}0.02-1.31{\pm}0.03$, 구치부에서 $1.40{\pm}0.03-1.33{\pm}0.02$로 유의한 차이가 있었고(P < 0.05), 수직 확대율은 차이가 없었다. 위치 변화에 따른 수평 확대율은 $0.88{\pm}0.03-3.73{\pm}0.16$으로 기준 위치와 비교 시 통계적으로 유의한 차이를 보인 반면 (P < 0.05), 수직 확대율은 $1.24{\pm}0.01-1.37{\pm}0.02$로 차이가 없었다. 결론: 회전된 머리위치에서 파노라마방사선사진 촬영 시 수평 확대율의 변화가 크다.

Alternative Description for Gaussian Image Plane

  • Kim, Byongoh;Lee, Sukmock
    • Journal of the Optical Society of Korea
    • /
    • 제19권2호
    • /
    • pp.144-148
    • /
    • 2015
  • An alternative description for the Gaussian image plane (GIP) of an optical system for a given object is presented, which applies to both aberration-free and non-aberration-free systems. We extend the definition of transverse magnification (TM) to the image plane (IP) displaced from the GIP and find that the TM depends linearly on the locations of both an aperture stop placed in front of the system and the IP. Hence, we redefine the GIP as the location at which the slope of the TM variance changes sign. The definition is deterministic and self-consistent and, therefore, no other parameters or measurements are needed. The derivation of this definition using a set of paraxial ray tracings and supporting experimental data for a thick bi-convex lens system is presented.

수종 레진으로 의치상 조직면 개조시 의치상의 크기변화와 물리적 성질 및 표면상태 비교 연구 (AN EXPERIMENTAL STUDY ON THE DIMENSIONAL CHANGES OF RELINED DENTURES AND MECHANICAL PROPERTIES AND SURFACE TEXTURES OF SEVERAL RESINS USED IN DENTURE RELINING)

  • 이창한;김영수
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.25-41
    • /
    • 1990
  • The purpose of this study was to evaluate and compare the dimensional changes of relined dentures with a light-curing resin, a heat-curing resin, and a direct, hard reline resin. And also to measure the transverse strength, impact strength, surface hardness of the three resins used in relining. The surface textures of three resins also of evaluated by using scanning electron microscope. Through analyses on the data from this study, the following conclusions were obtained. 1. Impact strength of heat-curing resin was highest, and direct, hard reline resin higher, light-curing resin lowest. 2. Transverse strength of heat-curing resin was highest, and direct, hard reline resin and light-curing resin was lower and not signiicantly different. 3. Surface hardness of light-curing resin was lighest, heat-curing resin higher, and direct, hard reline resin was lowest. 4. After storage of the relined dentures for 1 day and 1 week in water at room temperature, linear shrinkage of distance between the reference points in the maxillary base relined with direct, hard reline resin was lowest, and those relined with light-curing resin and heat-curing resin were lower and were not significantly different. 5. After storage for 4 weeks in orator at room tempeature, linear shrinkage of distance between ridge crests of dentures relined with heat-curing resin was highest and that of distance between denture borders was not significantly different. 6. The dimensional changes of relined dentures during storage in water was not significant except those of distance between denture borders relined with light-curing resin at 1 day and 1 week storage in water. 7. At low magnification (x40) of SEM examination, the surface textures of three resins were similar except light-curing resin which had some defects. At high magnification (x200), the surface textures of hard, direct reline resin were smooth with little defects, but those of heat-curing resin and light-curing resin w ere irregular.

  • PDF

고온고속류에서 기화를 고려한 연료액적의 분열(Breakup)기구 해석에 관한 연구 (A Study on Analysis of Breakup Mechanism of Vaporizing Fuel Droplet in High Temperature and Velocity Air Stream)

  • 김관철;황상순
    • 한국분무공학회지
    • /
    • 제3권3호
    • /
    • pp.1-13
    • /
    • 1998
  • In this study, an experimental study was performed to investigate the breakup mechanism of vaporizing droplet. A well-controlled experimental apparatus was used to study breakup mechanisms of a monodisperse stream of drops injected into a transverse high temperature and velocity air stream. The experiments gave information$ about the microscopic structure of the liquid drop breakup process, drop breakup regimes, and drop trajectories in high temperature flow region. The breakup time, drop acceleration and wavelength of surface instability wave were measured from a high-magnification and double spark photography. The two instability theories, i.e., Kelvin-Helmholtz instability and Rayleigh-Taylor instability, were estimated by comparing the calculated data with the measurements. The results showed that the breakup time in high temperature flow condition is shortened because the surface tension is decreased by the increase of gas temperature.

  • PDF

고속기류에 분사된 액적궤적 및 입경분포에 미치는 주위 기체밀도의 영향 (The effect of gas density on the drop trajectory and drop size distribution in high speed gas stream)

  • 이충훈
    • 한국분무공학회지
    • /
    • 제5권3호
    • /
    • pp.37-44
    • /
    • 2000
  • High velocity, gas-assisted liquid drop trajectories were investigated under well-controlled experimental conditions at elevated gas densities and room temperature. A monodisperse stream of drops which are generated by a vibrating-orifice drop generator were injected into a transverse high velocity gas stream. The gas density and air jet velocity were adjusted independently to keep the Weber numbers constant. The Weber numbers studied were 72, 148, 270, 532. The range of experimental conditions included studied the three drop breakup regimes previously referred as bag, stretching/thinning and catastrophic breakup regimes. High-magnification photography and conventional spray field photographs were taken to study the microscopic breakup mechanisms and the drop trajectories in high velocity gas flow fields, respectively. The parent drop trajectories were affected by the gas density and the gas jet velocities and do not show similarity with respect to the either Weber or the Reynolds number, as expected.

  • PDF

Numerical study on RC flat plates subjected to combined axial and transverse load

  • Park, Honggun
    • Structural Engineering and Mechanics
    • /
    • 제8권2호
    • /
    • pp.137-150
    • /
    • 1999
  • This paper presents a numerical study on the flat plates in deep basements, subjected to floor load and in-plane compressive load due to soil and hydraulic lateral pressure. For nonlinear finite element analysis, a computer program addressing material and geometric nonlinearities is developed. The validity of the numerical model is established by comparison with existing experiments performed on plates simply supported on four edges. The flat plates to be studied are designed according to the Direct Design Method in ACI 318-95. Through numerical study on the effects of different load combinations and loading sequence, the load condition that governs the strength of the flat plates is determined. For plates under the governing load condition, parametric studies are performed to investigate the strength variations with reinforcement ratio, aspect ratio, concrete strength, and slenderness ratio. Based on the numerical results, the floor load magnification factor is proposed.

2군 줌 복사기 렌즈계의 광학적 성능 (A study on the Optical Properties of two component zoom copier lens system)

  • 지택상;임현선;김봉환
    • 한국안광학회지
    • /
    • 제5권2호
    • /
    • pp.119-125
    • /
    • 2000
  • 본 연구에서는 기존에 설계된 2군 zoom 복사기 렌즈계를 선택하여 광학적 성능을 계산하고 분석하여 보았다. 이 렌즈계는 유한 물점에 대한 zoom 렌즈계로서 우리가 일반적으로 사용하는 무한 물점에 대한 카메라 zoom 렌즈와는 달리, 고정된 물체와 상면사이에서 움직이기 때문에 제한된 이동영역을 갖게 된다. 광학계의 배율은 횡배율로서 -1.41~0.64의 확대, 축소된 상을 얻을 수가 있고 f/12의 값과 약 $20^{\circ}$의 시야를 확보하고 있다. 이 2군 zoom 복사기 렌즈계는 카메라 렌즈가 갖는 f/2.8에 비하여 비록 어둡고 해상력이 떨어진다고 할 수 있으나, 전방 또는 후방에 보조군을 추가함에 의하여 보다 나은 수차보정과 large aperture를 가능하게 할 수 있는 가능성이 있다.

  • PDF

마이크로파 중합에 의한 의치상 레진의 물리적 성질에 관한 연구 (AN EXPERIMENTAL STUDY ON THE PHYSICAL PROPERTIES OF THE DENTURE BASE RESINS CURED BY MICROWAVE IRRADIATION)

  • 김학선;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.109-124
    • /
    • 1990
  • The purpose of this study was to investigate the physical propertise and determine whether three were any differences in the amount of porosity of the denture base resins cured by microwave irradiation and conventional water bath heating. The resins used in this study were K-33 resin and Acron MC resin. The properties selected were transverse strength, Knoop hardness, and density. A ten-power eyepiece and scanning electron microscope(Magnification of ${\times}$ 30and ${\times}$150)were used to examine the specimens for porosity. Through analyses of the data from this study, the following conclusions were obtained. 1. Microwave energy can be effectively use dtopolymerize poly(methylmethacrylate) denture base resins. 2. In the transverse strength, K-33 resin cured by microwave irradiation was the first highest, water bath cured K-33 resin the second, microwave cured Acron MC resin the third, water bath cured Acron MC resin the fourth. 3. In the Knoop hardness, K-33 resin cured by microwave irradiation was the first hardest, water bath cured K-33 resin the second, water bath cured Acron MC resin the third, microwave cured Acron MC resin the the fourth. 4. No significant difference was found between the density of resin denture bases polymerized by either method. 5. K-33 resin showed the most porosity for the microwave curing. But there was no significant difference in the Acron MC resin and other curing method.

  • PDF