• Title/Summary/Keyword: Transmission Zero

Search Result 330, Processing Time 0.032 seconds

Probe Design and Fabrication for Measuring Near Field (근역장 측정용 프로브의 설계 및 제작)

  • 김병찬;최형도;이애경;이형수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.2
    • /
    • pp.164-169
    • /
    • 2002
  • This paper reports on design and fabrication of near field probe operating at 300~3000 MHz. Design parameters are extracted by equivalent circuit of E-field probe and simulation using S parameter is performed to predict probes performance. The probe consists of a dipole antenna with 3.25 mm length, a zero bias Schottky diode and a highly resistive transmission line. A TEM cell was used for performance evaluation.

Derivation of Transfer Function for the Cross-Coupled Filter Systems Using Chain Matrices

  • Um, Kee-Hong
    • International journal of advanced smart convergence
    • /
    • v.7 no.1
    • /
    • pp.7-14
    • /
    • 2018
  • In this paper, we derive a transfer function of cross-coupled microwave filter systems by using a characteristics of chain matrices. Depending on the lumped element of capacitor or inductor, the cross-coupled system is negatively- or positively system. We used a ladder network as a starting system composed of several subsystems connected in chain. Each subsystem is descrived by Laplace impedance. By solving the transmission zero characteristic equation derived from the cascaded subsystems, we can find the zeros of filter system with externally cross-coupled lumped elements. With the cross-coupled elements of capacitors, the numerator polynomial of system transfer function is used to locate the quadruplet zeros in complex plane. We show the polynomoials of numerator and denominator of cascaded transfer function, obtaining the zeros of the cross-coupled system.

Fault Detection Relaying for Transmission line Protection using ANFIS (적응형 퍼지 시스템에 의한 송전선로보호의 고장검출 계전기법)

  • 전병준
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.9 no.5
    • /
    • pp.538-544
    • /
    • 1999
  • In this paper, we propose a new fault detection algorithm for transmission line protection using ANFIS(Adaptive Network Fuzzy Inference System). The developed system consists of two subsystems: fault type classification, and fault location estimation. We use rms value, zero sequence component and positive sequence of current, and then using learning method of neural network, premise and consequent parameters are tuned properly. To prove the performance of the proposcd system, generated data by EMTP(Electr0- Magnetic Transient Program) sin~ulationi s used. It is shown that the proposed relaying classifies fault types accurately and advances fault location estimation.

  • PDF

A Directional Relay Algorithm Using Positive-Sequence Superimposed Quantity for Transmission Line Protection (정상 성분 변화량을 이용한 송전선로 보호용 방향 계전 알고리즘)

  • 이명수;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.226-233
    • /
    • 2003
  • Directional elements are fundamental to protection scheme security and selectivity, performing such critical tasks as supervising distance elements and controlling overcurrent elements. But, conventional operating principles for directional detection based on negative or zero sequence quantify do not satisfy the requirements for improved sensitivity and fast operation under any fault conditions. In this paper, new algorithm for directional elements is proposed. The proposed algorithm use the positive-sequence superimposed voltages and currents in order to be used in all fault conditions. Also, because this algorithm uses a voltage compensation method. it can be well operated under strong source conditions.

Fault Location Estimation Algorithm of the parallel transmission lines using a variable data window method (가변 데이터 윈도우 기법을 이용한 병행 2회선 송전선 고장점 추정 알고리즘)

  • Jung, Ho-Sung;Yoon, Chang-Dae;Lee, Seung-Youn;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.266-268
    • /
    • 2003
  • This paper proposes the Fault Location Estimation Algorithm in the parallel transmission lines. These algorithm uses a variable data window method based on least square error method to estimate fault impedance quickly. And it selects the optimal equation according to the operation situation and usable fault data for minimizing the fault estimation error effected by the zero sequence mutual coupling. After simulation result, we can see that these algorithm estimates fault location more rapidly and exactly.

  • PDF

Impedance Matching Characteristic Research Utilizing L-type Matching Network

  • Jun Gyu Ha;Bo Keun Kim;Dae Sik Junn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.2
    • /
    • pp.64-71
    • /
    • 2023
  • If an impedance mismatch occurs between the source and load in a Radio Frequency transmission system, reflected power is generated. This results in incomplete power transmission and the generation of Reflected Power, which returns to the Radio Frequency generator. To minimize this Reflected Power, Impedance matching is performed. Fast and efficient Impedance matching, along with converging reflected power towards zero, is advantageous for achieving desired plasma characteristics in semiconductor processes. This paper explores Impedance matching by adjusting the Vacuum Variable Capacitor of an L-type Matching Module based on the trends observed in the voltage of the Phase Sensor and Electromotive Force voltage. After assessing the impedance matching characteristics, the findings are described.

  • PDF

New Vibration Suppression Control of 2-Mass System using $H_{\infty}$ Filter (2관성계의 $H_{\infty}$ 필터를 이용한 새로운 전동억제제어)

  • 김진수;유상봉
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.339-342
    • /
    • 2002
  • In the industrial motor drive system which is composed of a motor and load connected with a flexible shaft, a torsional vibration is often generated because of the elastic elements in torque transmission. To solve this problem H$_{\infty}$ controller was designed. In this paper, H$_{\infty}$ control of 2-mass system using H$_{\infty}$ filter for compensating shaft torque is proposed. Pole-zero maps show the validity of proposed controller.

  • PDF

Optical Pulse Compression at $1.319{\mu}m$ Through Fiber-grating Pair (광섬유와 회절격자를 이용한 $1.319{\mu}m$ 파장 광펄스의 압축)

  • 이재승;박희갑;심창섭
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.13-19
    • /
    • 1991
  • Utilizing self-phase modulation effects of a dispersion-shifted fiber and delayline characteristics of two gratings, mode-locked 80 ps pulses at 1.319 $\mu \textrm m$ wavelength from a Nd:YAG laser are compressed to 2.1 ps. This experiment is suitable for studying the transmission characteristics of high energy short pulses along normal fibers in zero dispersion regime.

  • PDF

Polarization Independent, Figure-Eight Birefringent Sagnac Variable Comb-Filter/Attenuator

  • Kim, Sung-Won;Kang, Jin-U
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2004.02a
    • /
    • pp.298-299
    • /
    • 2004
  • We propose and theoretically analyze multi-functional integrated optical device based on figure-eight shaped birefringent Sagnac loops. Our analysis shows that the propose device exhibit many unique features which allows it to operate as a tunable high-Q comb filter with a good channel isolation, and the intensity transmission of the filter can be varied from zero to 100 percent.

  • PDF

THE EFFECTS OF Sm ON THE MICROSTRUCTURE AND MAGNETOSTRICTION OF Fe-Co ALLOYS

  • Shima, Toshiyuki;Aoyagi, Eiji;Fujimori, Hiroyasu
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.726-729
    • /
    • 1995
  • We investigated the effects of Sm on the microstructure and magnetic properties of Fe-Co Alloy films prepared by a DC triode sputtering. The magnetostriction was found to be changed with the Sm content from positive to negative values, taking a zero magnetostriction was at about 3 at% Sm. The Sm content dependence of magnetostriction was explained by the formation of Sm enriched amorphous phase surrounding the main bcc (Fe,Co) crystalline phase, which was observed by a high resolution transmission electron microscopy.

  • PDF