• Title/Summary/Keyword: Transmission Width

Search Result 371, Processing Time 0.034 seconds

Basic study on laser triggered lightning : The generation of plasma channel by ${CO}_{2}$ laser (레이저에 의한 誘雷의 기초적 연구 -${CO}_{2}$ 레이저에 의한 플라즈마 채널 발생-)

  • 장용무;강형부
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.289-293
    • /
    • 1996
  • The basic study on laser triggered lightning was carried out for the active protection of lightning in power transmission system. The lengths of generated plasma channels were simulated numerically for variations of energy and pulse width of CO$_{2}$ laser by Runge-Kutta-Gill method. As results, the effective lengths of plasma channels were 2.3m, 2.67m and 3.4m respectively for energy of 45J, 60J and 100J of CO$_{2}$ laser pulse with pulse width of 50nsec using focusing mirror with focal length of 10m. And also the effects of pulse width of first pulse and tail pulse of CO$_{2}$ laser on the length of plasma channel were examined.

  • PDF

A Study on Inter-leaf Transmission and Cross-leaf Transmission for Clinical Applications of the Multileaf Collimator (다엽 콜리메이터의 임상적용을 위한 엽측간 투과선량 및 엽종단간 투과선량 연구)

  • 이규찬;최진호
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.17-22
    • /
    • 2004
  • Multileaf collimator (MLC) is now rapidly replacing the lead ahoy block to shape the radiation treatment field. In addition to its defect of rectangular field shaping and increased penumbra width, it has another possible problem, and that is of radiation transmission between leaves, which needs to be maintained at as low a level as is permissible. The authors measured and analyzed the inter-leaf and cross-leaf transmissions of MLC by Varian Associates Inc, before its clinical application. The inter-leaf and cross-leaf transmissions were calculated by comparing the measured point doses in the polystyrene phantom in the open field and in a total closure of MLC. The beam profile of the inter-leaf and cross-leaf transmissions were depicted by using a water phantom. A photon beam of 6 MV was used in the measurement. The inter-leaf transmission was 1.63∼1.67%, indicating that the shielding effect of MLC is excellent. However, the cross-leaf transmission in the central area was 18.4∼18.7% and this is well over the clinically acceptable limitation of 5%. The beam profile of cross-leaf transmission displayed 80∼90% transmission near the field edge, so that the cross-leaf transmission was 14∼17% in this area. The multileaf collimator has an excellent shi디ding effect and the inter-leaf transmission is negligible so that it can be used in clinic as a good replacement of the conventional lead alloy block. However, care must be taken to avoid the cross-leaf transmission in the radiation field.

  • PDF

Fully Integrated Electromagnetic Noise Suppressors Incorporated with a Magnetic Thin Film on an Oxidized Si Substrate

  • Sohn, Jae-Cheon;Han, S.H.;Yamaguchi, Masahiro;Lim, S.H.
    • Journal of Magnetics
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 2007
  • Si-based electromagnetic noise suppressors on coplanar waveguide transmission lines incorporated with a $SiO_2$ dielectric layer and a nanogranular Co-Fe-Al-O magnetic thin film are reported. Unlike glass-based devices, large signal attenuation is observed even in the bare structure without coating the magnetic thin film. Much larger signal attenuation is achieved in fully integrated devices. The transmission scattering parameter ($S_{21}$) is as small as -90 dB at 20 GHz at the following device dimensions; the thicknesses of the $SiO_2$ and Co-Fe-Al-O thin films are 0.1 $\mu$m and 1 $\mu$m, respectively, the length of the transmission line is 15 mm, and the width of the magnetic thin film is 2000 $\mu$m. In all cases, the reflection scattering parameter ($S_{11}$) is below -10 dB over the whole frequency band. Additional distributed capacitance formed by the Cu transmission line/$SiO_2$/Si substrate is responsible for these characteristics. It is considered that the present noise suppressors based on the Si substrate are a first important step to the realization of MMIC noise suppressors.

Power Splitting of Plasmonic Directional Couplers with Nano-scale Three Channels (나노 크기의 세 채널 플라즈마 방향성 결합기의 전력분배)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.3
    • /
    • pp.47-52
    • /
    • 2011
  • Directional couplers based on plasmonic waveguides with nano-scale three channels are designed by utilizing mode coupling effect as well as rib-guiding structure. Longitudinal modal transmission-line theory(L-MTLT) is used for simulating the light propagation and optimizing the design parameters. The designed plasmonic coupler operating as power splitter has nano-scale size of about 200~250 nm width. In order to achieve the desired power splitting ratio, the refractive index of guiding modes is evaluated along the width variation of center channel. Finally, a power splitter based on triple rib directional coupler, which ensures maximum power transfer from one outermost guide to the other outermost guide, is designed.

ELECTRON MICROSCOPIC STUDY OF THE IRRADIATION EFFECT ON THE RAT MANDIBULAR CONDYLE (방사선조사가 하악과두에 미치는 영향에 관한 전자현미경적 연구)

  • Park Myoung Seon;Park Tae Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.45-63
    • /
    • 1996
  • In attempt to determine radiation effect on the mandibular condyle of the growing rat, 27 white female rats (Sprague-Dawley) were divided into 3 groups and irradiated respectively 5Gy, 10Gy, 20Gy using MK Cell Irradiator. Mandibular condyles from rats on the day of 1, 7, 14 after the irradiation day were obtained, sectioned sagittally and examined by light microscopy, and thereafter middle portion through anteroposterior direction on the sagittal plane was selected to examine the ultrastructural change by transmission electron microscopy. The obtained results are followings. 1. In the proliferative zone some cells showed little organelles in case of 5Gy irradiation, in addition the number of degenerative cells increased and in case of 10Gy irradiation, and in case of 20 Gy irradiation total number of cells decreased. 2. In the hypertrophic zone, narrowing of width and partial disorder in hypertrophic process were noted in case of 5 Gy irradiation, and more prominent narrowing of width and more irregular disorder in hypertrophic process in case of both 10Gy and 20Gy irradiation. 3. In the upper hypertrophic zone some chondrocytes seemed to be dying and the polarity of nuclei could not be seen, if any. 4. The periodic observation showed the severest change at day 7 and the signs of recovery at day 14 after irradiation.

  • PDF

Active Voltage-balancing Control Methods for the Floating Capacitors and DC-link Capacitors of Five-level Active Neutral-Point-Clamped Converter

  • Li, Junjie;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.653-663
    • /
    • 2017
  • Multilevel active neutral-point-clamped (ANPC) converter combines the advantages of three-level ANPC converter and multilevel flying capacitor (FC) converter. However, multilevel ANPC converter often suffers from capacitor voltage balancing problems. In order to solve the capacitor voltage balancing problems for five-level ANPC converter, phase-shifted pulse width modulation (PS-PWM) is used, which generally provides natural voltage balancing ability. However, the natural voltage balancing ability depends on the load conditions and converter parameters. In order to eliminate voltage deviations under steady-state and dynamic conditions, the active voltage-balancing control (AVBC) methods of floating capacitors and dc-link capacitors based on PS-PWM are proposed. First, the neutral-point current is regulated to balance the neutral-point voltage by injecting zero-sequence voltage. After that, the duty cycles of the redundant switch combinations are adjusted to balance the floating-capacitor voltages by introducing moderating variables for each of the phases. Finally, the effectiveness of the proposed AVBC methods is verified by experimental results.

Quantitative Evaluation of Dislocation Density in Epitaxial GaAs Layer on Si Using Transmission Electron Microscopy

  • Kim, Kangsik;Lee, Jongyoung;Kim, Hyojin;Lee, Zonghoon
    • Applied Microscopy
    • /
    • v.44 no.2
    • /
    • pp.74-78
    • /
    • 2014
  • Dislocation density and distribution in epitaxial GaAs layer on Si are evaluated quantitatively and effectively using image processing of transmission electron microscopy image. In order to evaluate dislocation density and distribution, three methods are introduced based on line-intercept, line-length measurement and our coding with line-scanning method. Our coding method based on line-scanning is used to detect the dislocations line-by-line effectively by sweeping a thin line with the width of one pixel. The proposed method has advances in the evaluation of dislocation density and distribution. Dislocations can be detected automatically and continuously by a sweeping line in the code. Variation of dislocation density in epitaxial GaAs films can be precisely analyzed along the growth direction on the film.

A Study on the Analysis of Hydraulic Circuit for First Pressure Control of Automatic Transmission KICK DOWN System (자동변속기 KICK DOWN 시스템의 1차 압력 제어를 위한 유압 회로 해석에 관한 연구)

  • 김대중;송창섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.171-179
    • /
    • 1991
  • This paper refers to the results of a study on the usefulness of simulation techniques based on both modeling and experiments of KICK DOWN pressure control circuit using an duty solenoid valve controlled by pulse width modulation for an automatic transmission. In this study, dynamic characteristics of solenoid valve plunger and first pressure are verified. Besides, this paper shows the design data for improvement of feeling in changing of gear by means of simulation according to varying the size of jet orifice and temperature of automatic transmission fluid, which are the important variables of the first pressure.

  • PDF

Modelling and Performance Analysis of UPFC Using EMTP/ATPDraw (EMTP/ATPDraw를 이용한 UPFC구현 및 동작 분석)

  • Jang, Won-Hyeok;Lee, You-Jin;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.217-219
    • /
    • 2008
  • Among the Flexible AC Transmission Systems (FACTS) devices, Unified Power Flow Controller (UPFC) is considered as the most powerful and versatile one as it provides simultaneous, real time control of the transmission parameters, voltages, impedances, and phase angles which determine the power flow in AC transmission systems. This paper presents modelling of UPFC and describes its characteristics. The UPFC implemented in this paper is based on Sinusoidal Pulse Width Modulation (SPWM) and Electro-Magnetic Transients Program (EMTP)/ATPDraw is used to model and analyze it. The simulation results confirm advantages of UPFC in operational performance with respect to the steady state Power flow regulation and the transient stability control.

  • PDF

The Study on the Optimal Transmission Efficiency Characteristics of Pulse Energy Using Magnetic Pulse Compressors (가포화 자기스위치 MPC를 적용한 저온 플라즈마의 펄스에너지 전송효율 특성)

  • 이유수;정종한;정현주;김문환;김희제
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.383-387
    • /
    • 2003
  • In this paper, we have studied about optimal transmission efficiency characteristics of pulse energy in a coal plant for removing environmental polluted gas. The electrical efficiency of pulse power systems depends on impedance of the reactor. To obtain high efficiency, we used MPC(Magnetic pulse compressor) as the power switch and tested their characteristics as electrode length of the reactor and charging voltage of capacitor, As results, we obtained a compressed pulse such as pulse voltage of 10㎸, rising time 200ns and pulse width of 500ns. With increasing electrode length, the load impedance was decreased but the electrical efficiency was increased.