• Title/Summary/Keyword: Transmission Suspension Insulator

Search Result 32, Processing Time 0.044 seconds

Development of Live-line Insulator Inspection Robot System for both Suspension and Tension Insulator Strings (현수/내장애자련 겸용 활선애자 점검로봇 시스템 개발)

  • Park, Joon-Young;Lee, Jae-Kyung;Oh, Ki-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1239-1244
    • /
    • 2011
  • In our previous paper, we developed an insulator inspection robot system for a suspension insulator string in the 345kV power transmission line. However, this robot cannot be applied to a tension insulator string, because its constituent insulators are different in diameter and height from those of a suspension insulator string. To solve this problem, we developed a new live-line insulator inspection robot system that is applicable to both suspension and tension insulator strings. We confirmed its effectiveness through live-line performance tests.

Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test (송전용 폴리머 애자의 산불 모의시험에 따른 표면열화 특성)

  • Cho, Han-Goo;Kim, Kyang-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.110-110
    • /
    • 2010
  • Suspension insulator have made use of porcelain insulator mainly, but polymer insulator is using recently. Polymer suspension insulator have advantage that it is light than porcelain insulator. The ageing performance is excellent and it is possible for mass production. There is high possibility of mountain fire because a lot of potential inflammables such as fallen leaves are stacked on the ground Therefore surface aging of polymer insulator most of the overhead transmission lines in Korea are operated on the mountain need analysis of transmission line into forest fire. surface aging property is analyzed by SEM, EDX, XPS, FTIR, DSC in this paper.

  • PDF

Evaluation of Material Characteristics of Suspension-Type Porcelain Insulators for 154 KV Power Transmission Lines

  • Choi, In-Hyuk;Park, Joon-Young;Kim, Tae-gyun;Yoon, Yong-Beum;Yi, Junsin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.4
    • /
    • pp.207-210
    • /
    • 2017
  • The suspension arrangement of insulators provides flexibility and assists in power transmission in transmission lines. The performance of the insulator string is strongly influenced by the environmental conditions to which it is exposed, its shape and the inherent material properties of suspension-type insulators. The suspension-type insulators are mostly made from glass, porcelain and ceramic material due to their high resistivity. Irregularity in charge distribution throughout the porcelain insulator may lead to accelerated aging and electrical breakdown. A very high and steep lightning impulse voltage may also cause breakdown of suspension-type insulators. We investigated various material characteristics such as alumina addition, surface morphology, x-ray diffraction pattern and relative density of suspension porcelain insulators manufactured in 1989 (36,000 lbs.), 1995 (36,000 lbs.) and 2001 (36,000 lbs.) by the KRI Company for use in 154 kV high power transmission lines. We compared the material characteristics of these porcelain insulators with that of the top-of-the-line porcelain insulators (36,000 lbs.) manufactured by the NGK Company in 2000. These suspension-type porcelain insulators were exposed to arc and flashover tests to examine their electrical and mechanical strength. It was noted that alumina addition (17 wt.%) for K-2001 was one of the major contributors to the enhancement of the performance of the porcelain insulators and to their ability to withstand very high current generation during the arc test. The porcelain insulators manufactured during 2001 also showed the highest relative density of 95.8% as compared to the other insulators manufactured in 1989 and 1995 respectively 94.2% and 91.5%. We also discuss reports of various failure modes of suspension-type porcelain insulators.

Tracking Property of Polymer Suspension Insulator for Transmission line with secular variation (경년변화에 따른 송전용 폴리머 현수애자의 트래킹 성능평가)

  • Cho, Han-Goo;Lee, Un-Yong;Lee, You-Jung;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.558-559
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. In this paper, the tracking property of polymer suspension insulator for power transmission is investigated with CEA tracking wheel test. The diagnosis of insulator sample in tracking test has been analyzed by leakage current, STRI Guide, SEM, FTIR and thermal image.

  • PDF

The Design Analysis of Distribution Polymer Suspension Insulator (배전용 폴리머 현수애자의 설계해석)

  • Lee, Un-Yong;Cho, Han-Goo;Han, Dong-Hee;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.66-68
    • /
    • 2001
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, distribution polymer suspension insulator has been designed and investigated electric field distribution by FEM.

  • PDF

A Study on the Performance Evaluation of Transmission Suspension Insulators (송전용 현수애자의 성능평가에 관한 연구)

  • Song, Il-Geun;Kim, Chan-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.406-411
    • /
    • 2000
  • This paper presents the results of performance confirmation tests for domestic 20 [Ton] transmission suspension insulators which will be widely utilized in transmission lines. The new test methods such as power arc test, steep-front-of-wave flashover voltage test, and etc. which have been only utilized for the distribution insulators were applied in transmission suspension insulators. The properties of metal and cement used in the 20 [Ton] transmission insulators were also evaluated by the various analysis techniques. Based on the results, we evaluated the performance of the transmission suspension insulators.

  • PDF

Solid Core Suspension Disc Insulators Preventing Puncture Caused by Steep Front Surge Voltage

  • Sangkasaad, Samruay
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.165-170
    • /
    • 2003
  • This paper presents development of solid core suspension disc insulators (cap and cap suspension disc insulator) for replacing cap and pin suspension disc insulators in overhead transmission and distribution lines which expose to lightning discharges. By this means the punctured problem caused by steep front surge voltage created by lightning discharge on the lines can be solved. The solid core suspension insulator was designed and constructed based on the dimensions of conventional suspension disc insulators (cap and pin insulators). The insulators are made of alumina porcelain. The electrical and mechanical characteristics of the solid core suspension insulators were carried out. The puncture test was performed in the air by applying steep front impulse voltage with amplitude about 2.5 per unit of 50% flashover (CFO) of the insulator unit at negative standard lightning impulse $1.2/50\;\mu\textrm{s}$ with steepness up to $9200\;kV/\mu\textrm{s}$. The testing results show that solid core suspension disc insulators are not punctured eventhough the steepness of the steep front impulse voltage was increased up to $9200\;kV/\mu\textrm{s}$.

Various Factors Influencing the Lifetime of Suspension-Type Porcelain Insulators for 154 kV Power Transmission Lines

  • Choi, In Hyuk;Park, Joon Young;Kim, Tae Gyun;Yoon, Yong Beum;Yi, Junsin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.151-154
    • /
    • 2017
  • In this article, we investigated the various influencing factors that degraded the lifetime of suspension insulators in 154 kV transmission lines, and showed the possible solutions to avoid such breakdowns. With respect to achieve safety, reliability and aesthetical considerations, the characteristics of transmission and distribution network power cables should be improved. Suspension insulators are particularly important to study, as they have developed to be the main component of transmission lines due to their ability to withstand the electrical conductivity of high-voltage power transmission. Suspension insulators are mostly made from glass, rubber and ceramic material due to their high resistivity. In Korea, porcelain suspension insulators are typically used in the transmission line system, as they are cheaper and more flexible compared to other types of insulators. This is effective from preventing very high and steep lightening impulse voltages from causing the breakdown of suspension insulators used in power lines. Other influential factors affect the lifetime of suspension insulators that we studied include temperature, water moisture, contamination, mechanical vibration and electrical stress.

Surface and Tracking Properties of Polymer Suspension Insulator for Power Transmission with secular variation (경년열화에 따른 송전용 폴리머 현수애자의 표면 및 트래킹 성능)

  • Cho, Han-Goo;Lee, Un-Yong;Han, Se-Won;Han, Dong-Hee;Huh, Jong-Chul;Choi, In-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.233-236
    • /
    • 2004
  • Recently, the polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. The shape design of porcelain insulator is formalized but design standard for polymer insulator is no standardized up to now, much research is necessary in real condition. In this paper, the surface and tracking properties of polymer suspension insulator for power transmission is investigated with ICP-AES, SEM, EDX, tracking wheel test and flashover voltage test. The diagnosis of insulator sample in tracking test hass been analyzed by leakage current STRI Guide and thermal image.

  • PDF

A Variation of Maximum Stress with Axial Loading in Porcelain Insulators for Transmission Line using ANSYS (ANSYS를 이용한 송전용 자기재 애자의 장력에 따른 특성 변화)

  • Woo, B.C.;Han, S.W.;Cho, H.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.104-107
    • /
    • 2003
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of cement for suspension insulator. These simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing. These simulation analysis and experimental results show that axial loading affects of Porcelain insulators severely to be mechanical failure ageing.

  • PDF