• 제목/요약/키워드: Transmission Loss Factor

검색결과 158건 처리시간 0.031초

청감실험을 이용한 건축설비소음의 등급화 (Grading of Architectural Plumbing Noise using Psycho-Acoustic Experiment)

  • 유희종;정철운;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.488-492
    • /
    • 2007
  • Since Equipment-Noises occurring in machine room penetrate wall-body and travel to the adjacent room in the form of air-borne sound and structure-borne sound, it is appearing as the main factor that injures a peaceful residential environment, and due to this, such noise-damage is currently increasing rapidly. Consequently, despite the measures for sound-insulation and soundproof against the equipment-noise penetrated wall-body is urgently required, but as the subjective evaluation considered for psychological response about the equipment-noise was not practiced, many dissatisfactions are still raising even after some measure was taken. On such point of view, this Research, at the spot, has actually measured the equipment-noise that had permeated various wall-bodies, and examined its physical characteristics, thence based upon this, has conducted Psycho-Acoustics Experiment and investigated the interrelation between the physical evaluation value and psychological reaction value. It is considered that such study result could be utilized as the useful material at the time of establishment of the Grading Standard for the insulation performance against the Architectural Plumbing Noise, in the future.

  • PDF

장거리 해저 무중계 전송기술 연구 (Consideration for the Repeaterless Transmission in Long Distance Optical Submarine Cable System)

  • 박홍태;김천석
    • 한국전자통신학회논문지
    • /
    • 제2권1호
    • /
    • pp.40-45
    • /
    • 2007
  • 수백Km 정도의 섬과 섬 섬과 내륙을 해저광케이블로 연결하는 경우 일반 국가간의 500Km이상의 장거리의 중계기 증폭 시스템과 달리 송신단 및 수신단, 광케이블에 EDFA 기술을 적용하여 무중계 시스템을 설계할 수 있다. 중계기가 없음으로 해서 중계기에 공급하는 전력시스템, 동튜브가 내장된 해저케이블, 중계 증폭시 필요한 여기 파장공급용 Laser Diode등이 필요가 없어 고신뢰성 및 경제적인 시스템을 구성 할 수 있다. 그러나 중계 증폭을 하지 않는 만큼 저손실의 광케이블을 사용하여야 한다. 이러한 광증폭 제약 요소들을 고려하여 장거리 무중계 시스템을 고찰 하였다.

  • PDF

Optical and dielectric properties of SrMoO4 powders prepared by the combustion synthesis method

  • Vidya, S.;John, Annamma;Solomon, Sam;Thomas, J.K.
    • Advances in materials Research
    • /
    • 제1권3호
    • /
    • pp.191-204
    • /
    • 2012
  • In this paper, we report on the obtention of nanocrystalline $SrMoO_4$ synthesized through modified combustion process. These powders were characterized by X-ray diffraction, Fourier Transform Raman and Infrared Spectroscopy. These studies reveal that the scheelite-type $SrMoO_4$ crystallizes in tetragonal structure with I41/${\alpha}$ (N#88) space group. Transmission electron microscopy image shows that the nanocrystalline $SrMoO_4$ powders have average size of 18 nm. The optical band gap determined from the UV-V is absorption spectra for the as prepared sample is 3.7 eV. These powders showed a strong green photoluminescence emission. The samples are sintered at a relatively low temperature of $850^{\circ}C$. The morphology of the sintered pellet is studied with scanning electron microscopy. The dielectric constant and loss factor values obtained at 5 MHz for a well sintered $SrMoO_4$ pellet has been found to be 9.50 and $7.5{\times}10^{-3}$ respectively. Thus nano $SrMoO_4$ is a potential candidate for low temperature co-fired ceramics and luminescent applications.

Conductivity Evaluation of a Newly Proposed Material for a SAR Reflector Antenna

  • Yoon, Seong Sik;Lee, Jae Wook;Lee, Taek Kyung;Roh, Jin Ho;Kim, Hark Inn;Yi, Dong Woo
    • Journal of electromagnetic engineering and science
    • /
    • 제14권3호
    • /
    • pp.293-298
    • /
    • 2014
  • Large spaceborne antennas should be lightweight, a factor related to the development costs of launch vehicles. In order to overcome this drawback, a feasibility study of a new carbon fiber reinforced polymer (CFRP) named M55J/RS3 is carried out for a synthetic aperture radar (SAR) reflector antenna. In particular, the high resolution of detected images is taken into consideration. To validate the electrical performance, a test of the CFRP specimen is fabricated, and the transmission/reflection coefficients are measured using a standard X-band waveguide. Finally, the effective complex permittivity and effective electrical conductivity are derived from the obtained measured data. By applying the derived conductivity to the simulation of the radiation pattern, antenna gain, and beamwidth-instead of relying on the assumption of a perfect electric conductor-variations in electrical performance are also investigated and discussed.

Trust-aware secure routing protocol for wireless sensor networks

  • Hu, Huangshui;Han, Youjia;Wang, Hongzhi;Yao, Meiqin;Wang, Chuhang
    • ETRI Journal
    • /
    • 제43권4호
    • /
    • pp.674-683
    • /
    • 2021
  • A trust-aware secure routing protocol (TSRP) for wireless sensor networks is proposed in this paper to defend against varieties of attacks. First, each node calculates the comprehensive trust values of its neighbors based on direct trust value, indirect trust value, volatilization factor, and residual energy to defend against black hole, selective forwarding, wormhole, hello flood, and sinkhole attacks. Second, any source node that needs to send data forwards a routing request packet to its neighbors in multi-path mode, and this continues until the sink at the end is reached. Finally, the sink finds the optimal path based on the path's comprehensive trust values, transmission distance, and hop count by analyzing the received packets. Simulation results show that TSRP has lower network latency, smaller packet loss rate, and lower average network energy consumption than ad hoc on-demand distance vector routing and trust based secure routing protocol.

금속패널지붕의 열교 방지를 위한 열교차단장치 개발 및 적용효과 분석 (Study of Thermal Bridge Breaker to Prevent the Thermal Bridge Effect on Metal Panel Roofs)

  • 김선호;정채봉;이충식;김종민;김병철
    • 한국기계가공학회지
    • /
    • 제20권2호
    • /
    • pp.32-37
    • /
    • 2021
  • To realize a zero-energy building, a technology that minimizes the energy loss due to thermal bridges by preventing their formation is emerging as an important design factor. In this study, we develop a thermal bridge breaker to prevent thermal bridging in a metal panel roof and attempt to analyze the effects of its application. To this end, we fabricated a thermal bridge breaker and analyzed it in terms of its strength and heat-transfer characteristics, in addition to conducting a load simulation. The thermal bridge prevention effect of the developed thermal bridge breaker improved the insulation performance of the metal panel roof, and the results of a cooling/heating peak load simulation performed by applying the heat transmission resistance test results to a building proved the existence of this effect.

농촌주택표준설계도 에너지효율등급평가 및 설계변수에 따른 에너지소요량 변화에 관한 연구 (A Study on Energy Requirement Variation According to Energy Efficiency Rating Evaluation and Design Variable of Standard Design of Rural Houses)

  • 박미란;류연수;최정만;서혜원
    • 한국농촌건축학회논문집
    • /
    • 제19권2호
    • /
    • pp.9-16
    • /
    • 2017
  • The study analyzed the heat losses and the building energy efficiency grade by the energy simulation using the ENERGY# and ECO2 programs for the three types of Standard design of rural houses. It was calculated the energy efficiency rating by the ECO2 program for the rural housing standard design, and the energy demand and the energy consumption by each factor were compared and analyzed. And it analyzed energy consumption by element of each house by ENERGY # program. As a result, first in the evaluation of the energy efficiency grade of buildings by the ECO2 program, the rating for primary energy requirement for the housing newly built by the standard design of rural house is expected to range from 2 to 4 with 189.3 to $238.7kWh/m^2.a$. Second, the energy loss of each part of standard design of rural housing occurs in the order of ventilation 39%, window 33%, outer wall 14%, roof 9%, bottom 5%, and energy loss through ventilation and window occurs more than 70%. Third, the most beneficial effects on the energy efficiency grade is obtained the lowest grade of all three types by 2 when the lowering of the window and door heat transmission rate and the lowering of the light density, and the heat exchange ventilation device is not installed. Fourth, in the standard design of rural housing, the energy demand is occupied by heating > hot water > lighting order, and the order of the weight is changed in order of heating > lighting > ventilation > hot water. Fifth, building energy efficiency assessment system needs to establish policy for fixing rural housing energy as a practical device to ensure energy performance and quality.

Optical and dielectric properties of nano BaNbO3 prepared by a combustion technique

  • Vidya, S.;Mathai, K.C.;John, Annamma;Solomon, Sam;Joy, K.;Thomas, J.K.
    • Advances in materials Research
    • /
    • 제2권3호
    • /
    • pp.141-153
    • /
    • 2013
  • Nanocrystalline Barium niobate ($BaNbO_3$) has been synthesized by a novel auto-igniting combustion technique. The X-Ray diffraction studies reveals that $BaNbO_3$ posses a cubic structure with lattice constant $a=4.071{\AA}$. Phase purity and structure of the nano powder are further examined using Fourier-Transform Infrared and Raman spectroscopy. The average particle size of the as prepared nano particles from the Transmission Electron Microscopy is 20 nm. The UV-Vis absorption spectra of the samples are recorded and the calculated average optical band gap is 3.74eV. The sample is sintered at an optimized temperature of $1425^{\circ}C$ for 2h and attained nearly 98% of the theoretical density. The morphology of the sintered pellet is studied with Scanning Electron Microscopy. The dielectric constant and loss factor of a well-sintered $BaNbO_3$ at 5MHz sample is found to be 32.92 and $8.09{\times}10^{-4}$ respectively, at room temperature. The temperature coefficient of dielectric constant was $-179pp/^{\circ}C$. The high dielectric constant, low loss and negative temperature coefficient of dielectric constant makes it a potential candidate for temperature sensitive dielectric applications.

K-EMS 계통해석 어플리케이션을 위한 공통 데이터 모델 구축 (Common Data Model for Network Analysis Applications of K-EMS)

  • 윤상윤;조윤성;이욱화;손진만;남영우;이진;김홍래;김병호;김선구;허성일;이효상;신만철;민경일;최영진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.75-76
    • /
    • 2008
  • 본 논문에서는 한국형 에너지 관리 시스템의 계통 해석용 프로그램을 위한 공통 데이터 모델의 구축에 대해 다루었다. 공통 데이터 모델이란 다양한 어플리케이션이 공유하여 사용할 수 있는 계통 모델의 데이터베이스를 가리키며 본 논문에서는 토폴로지 프로세서(topology processor, TP), 상태추정(state estimator, SE), 급전원 조류계산(dispatcher power flow, DPF), 휴전계획(outage scheduler, OS), 부하 분포계수(bus load distribution factor, BLDF), 송전 손실 민감도 계수(transmission loss sensitivity factor, TLSF) 등을 위한 공통 모델에 대해 다루었다. 공통 모델의 구축을 위해 각 어플리케이션에서 필요한 정보를 수집하여 전력계통의 토폴로지 구조과 계통 설비를 모델링 하였다. 최종적으로 계층적(hierarchy) 구조와 비계층적(non-hierarchy) 구조로 나뉘어진 직접(direct) 및 간접(indirect) 인덱스 코드를 사용하여 데이터로의 빠른 접근이 가능한 실시간 데이터베이스 형태를 제시하였다.

  • PDF

An ICI Canceling 5G System Receiver for 500km/h Linear Motor Car

  • Suguru Kuniyoshi;Rie Saotome;Shiho Oshiro;Tomohisa Wada
    • International Journal of Computer Science & Network Security
    • /
    • 제23권6호
    • /
    • pp.27-34
    • /
    • 2023
  • This paper proposed an Inter-Carrier-Interference (ICI) Canceling Orthogonal Frequency Division Multiplexing (OFDM) receiver for 5G mobile system to support 500 km/h linear motor high speed terrestrial transportation service. A receiver in such high-speed train sees the transmission channel which is composed of multiple Doppler-shifted propagation paths. Then, a loss of sub-carrier orthogonality due to Doppler-spread channels causes ICI. The ICI Canceler is realized by the following three steps. First, using the Demodulation Reference Symbol (DMRS) pilot signals, it analyzes three parameters such as attenuation, relative delay, and Doppler-shift of each multi-path component. Secondly, based on the sets of three parameters, Channel Transfer Function (CTF) of sender sub-carrier number 𝒏 to receiver sub-carrier number 𝒍 is generated. In case of 𝒏≠𝒍, the CTF corresponds to ICI factor. Thirdly, since ICI factor is obtained, by applying ICI reverse operation by Multi-Tap Equalizer, ICI canceling can be realized. ICI canceling performance has been simulated assuming severe channel condition such as 500 km/h, 2 path reverse Doppler Shift for QPSK, 16QAM, 64QAM and 256QAM modulations. In particular, for modulation schemes below 16QAM, we confirmed that the difference between BER in a 2 path reverse Doppler shift environment and stationary environment at a moving speed of 500 km/h was very small when the number of taps in the multi-tap equalizer was set to 31 taps or more. We also confirmed that the BER performance in high-speed mobile communications for multi-level modulation schemes above 64QAM is dramatically improved by the use of a multi-tap equalizer.