• Title/Summary/Keyword: Transmission Line Parameter

검색결과 115건 처리시간 0.029초

EMTP를 이용한 765kV 송전선로 다상 섬락에 관한 연구 (A Study on Multi-Phase Flashover in 765kV Transmission Line using EMTP)

  • 가복현;민석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1586-1588
    • /
    • 1998
  • To use the EMTP, in this paper, a arcing horn is simulated by non-linear resistor and inductor element using TACS, a tower by distributed parameter model, and lines as K. C. Lee model. Changing lightning current characteristics, lightning position, and tower footing resistor value, we analysis multi-phase flashover characteristics in 765 kV transmission line.

  • PDF

S-파라미터 변환을 통한 비대칭 분배되는 임피던스 변환기 (An Impedance Transformer with Unequal Split Based on S-Parameter Conversion)

  • 김영
    • 한국항행학회논문지
    • /
    • 제20권4호
    • /
    • pp.361-366
    • /
    • 2016
  • 본 논문은 S-파라미터를 어드미턴스 파라미터로 변환하는 것을 바탕으로 비대칭 분배되면서 동시에 임의의 임피던스로 변환시킬 수 있는 임피던스 변환기를 나타내었다. 회로 해석 방법을 우수/ 기수 모드 방법과 비교하면 본 논문의 파라미터 변환을 통한 방법은 위상 지연 정보와 임의의 포트 임피던스 값을 포함시키고 그리고 비대칭 구조등을 해석하는데 간단함을 알 수 있다. 이 설계 방법의 타당성을 확인하기 위해서 중심주파수 1 GHz에서 3:1의 비대칭 분배비율을 갖고 있고 $50{\Omega}$$12.5{\Omega}$ 비율로 변환되는 임피던스 변환기를 설계하였다. 임피던스 변환기를 구현하는 방법은 유도된 수식으로부터 계산된 작은 임피던스 선로를 병렬 오픈스터브가 연결된 전송선로를 사용하여 구현하였고, 이것의 실험 결과는 시뮬레이션 결과와 동일하게 나옴을 확인하였다.

송전선로 고장과 LPATS 낙뢰자료 DB와의 비교분석에 관한 연구 (A study on the comparison/analysis between the fault of transmission line and the LPATS lightning data)

  • 우정욱;심응보;김정부;이건웅;민병욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2073-2075
    • /
    • 1999
  • To study the basic research of the lightning parameter for power system operation. LPATS(Lightning Position and Tracking System) has been introduced since 1995 in KEPCO. We have developed the lightning parameter analysis program. We obtained the various statistical distribution of lightning current parameters from 1995 by this program. In this paper, we describe the results on the comparison/analysis between the fault of transmission line and the LPATS lightning data.

  • PDF

근역장 측정용 프로브의 설계 및 제작 (Probe Design and Fabrication for Measuring Near Field)

  • 김병찬;최형도;이애경;이형수
    • 한국전자파학회논문지
    • /
    • 제13권2호
    • /
    • pp.164-169
    • /
    • 2002
  • 본 논문에서는 300~3000 MHz 의 주파수 영역에서 동작하는 근역장 측정 프로브를 설계하여 제작하였다. 설계 파라미터는 프로브에 대한 등가회로를 이용하여 추출하였으며 S파라미터를 이용한 수치해석을 통해 그 특성을 예측하였다. 제작된 프로브는 3.25 mm 길이의 다이폴 안테나와 제로 바이어스 쇼트키 다이오드, 고저항 전송 선으로 구성되어 있으며 TEM 셀을 이용하여 성능을 확인하였다.

송전선로의 고장점 표정 알고리즘 (An Algorithm of fault Location Technique for Long Transmission Line)

  • 박철원;김삼룡;신명철;남시복;이복구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.145-147
    • /
    • 2002
  • In this paper, the improved fault locating method using distributed parameter which calculating the reduced voltage and current according to the ground capacitance in long transmission line was proposed. For the purpose of the fault locating algorithm non influenced source impedance, the loop method was used in the system modeling analysis. To enhance the fault locating, zero sequence of the fault current which is variable according to ground capacitance was not used but positive and negative sequence. System model was simulated using EMTP software. To verify the accuracy of proposed method, in different cases 64 sampled data per cycle was used and 160km and 300km long transmission line has fault resistance $0{\Omega}\;and\;100{\Omega}$ respectively was compared.

  • PDF

전송선로를 가진 Chua 회로에서의 카오스 현상 해석 (Analysis of Chaotic Phenomena with Transmission line of Chua's Circuit)

  • 고재호;배영철;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.533-535
    • /
    • 1997
  • Chua's circuit is a simple electronic network which exhibits a variety of bifurcation and attractors. The circuit consists of two capacitors, an inductor, a linear resistor, and a nonlinear resistor. In this paper we analyze a circuit obtained by replacing the parallel LC resonator in the Chua's circuit by lossless transmission line. By using the method of characteristics of this circuit we show that various periodic motions and chaotic motions can the attained according to parameter variations. From Chua's circuit with a lossless transmission line, a variety of chaotic attractors which are similar to those of the normal Chua's circuit are observed.

  • PDF

마이크로스트립 Meander 라인의 S-파라메터 특성 (S-Parameter Characteristics of Microstrip Meander Line)

  • 김태원;신용조;김윤석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1201-1202
    • /
    • 2008
  • In this paper, using symmetrical condensed node(SCN), the TLM numerical technique has been successfully applied to microstrip meander line. A detailed technique of the symmetrical condensed node(SCN) may be used to model planar microstrip transmission line is presented. Also, the S-parameters $S_{11}$ and $S_{21}$ of microstrip meander line have been computed. From obtained results, TLM analysis is shown to be an efficient method for modeling complicated structure of planar microstrip transmission line.

  • PDF

장거리 송전선로를 고려한 사고거리추정 수치해석 알고리즘 (A Numerical Algorithm for Fault Location Estimation Considering Long-Transmission Line)

  • 김병만;채명석;강용철
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2139-2146
    • /
    • 2008
  • This paper presents a numerical algorithm for fault location estimation which used to data from both end of the transmission line. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the PMUs(Phasor Measurement Units) in the time-domain. This paper has separated from two part of with/without shunt capacitance(short/long distance). Most fault was arc one-ground fault which is 75% over [1]. so most study focused with it. In this paper, the numerical algorithm has calculated to distance for ground fault and line-line fault. In this paper, the algorithm is given with/without shunt capacitance using II parameter line model, simple impedance model and estimated using DFT(Discrete Fourier Transform) and the LES(Least Error Squares Method). To verify the validity of the proposed algorithm, the EMTP(Electro- Magnetic Transient Program) and MATLAB did used.

확장된 TRL 오차 수정 방법 (An Extended TRL Calibration Method)

  • 김유신;이창석
    • 한국전자파학회논문지
    • /
    • 제16권11호
    • /
    • pp.1099-1105
    • /
    • 2005
  • TRL 오차 수정 방법은 PCB 위에 제작된 고주파 소자를 측정할 때 많이 사용되는 방법이지만 오차 수정을 위해 제작된 표준 전송선 패턴의 특성 임피던스를 알아야만 보다 정확하게 측정 오차를 수정할 수 있다. 기존의 방법에서는 저항을 종단 처리한 표준 패턴을 추가로 이용하여 전송선의 단위 길이당 커패시턴스를 계산하고 주파수에 대해 fitting하는 방법으로 표준 전송선의 특성 임피던스를 계산하고 있으나 제작상의 부정확성에 의해 추출된 특성 임피던스가 영향을 받고 있음을 확인하였다. 본 논문에서는 측정된 S-parameter를 이용하여 제작상의 부정확성을 줄일 수 있고 기존 방법보다 정확한 특성 임피던스를 추출할 수 있다.

테라급 스위치 패브릭 인터페이스를 위한 고속 신호 전송로의 성능 분석 (Performance Analysis of High-Speed Transmission Line for Terabit Per Second Switch Fabric Interface)

  • 최창호;김환우
    • 전자공학회논문지
    • /
    • 제51권12호
    • /
    • pp.46-55
    • /
    • 2014
  • 고속 전송로를 위한 PCB(Printed Circuit Board) 설계기술은 꾸준히 발전되고 있으며, 통신 시스템의 대용량화에 맞추어 백플레인(Backplane)에 사용되는 스위치 패브릭 인터페이스(Switch Fabric Interface) 또한 10Gbps 이상의 직렬 인터페이스(Serial Interface)를 사용하도록 표준화가 진행되고 있다. 본 논문에서는 테라급 시스템에서 스위치 패브릭 인터페이스로 11.5Gbps의 직렬링크를 사용하기 위하여, PCB 재질 따른 전송로의 전송거리 별 성능을 비교하고, 비아 스터브(Via Stub)의 길이에 의한 영향 및 누화현상(Crosstalk)에 의한 영향을 시뮬레이션을 수행하여 분석하였다. 시뮬레이션의 결과로 백플레인 보드에 저유전 재질 PCB를 사용함으로써, 전송손실에서 8dB의 개선효과를 얻어 표준에서 정한 -25dB 기준을 만족하는 것을 확인하였다. 또한 비아 스터브 길이에 의한 반사손실의 영향을 분석하여 백드릴(Back-drill)여부를 결정하였으며, 전송신호 간 상호간섭을 최소화하는 이격거리를 검증하였다. 이러한 시뮬레이션의 결과로부터 모든 스위치 패브릭 링크에 11.5Gbps의 직렬 링크를 적용할 수 있도록 가장 효율적인 시스템구조를 확정하였다.