• 제목/요약/키워드: Transmission Angle

검색결과 600건 처리시간 0.03초

비균일 선형 전송선로에 관한 연구 (A Study on Nonuniform Transmission Lines with Linear Taper)

  • 홍성용;김세윤;나정웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.443-446
    • /
    • 1990
  • Comparison between two approaches for analysis of nonuniform transmission line with linear taper is presented. The input impedance evaluated analytically for tapered angle $2^{\circ}$ is deviated about 2.5% from that of numerical approach. The validity of our analytic method is illustrated physically.

  • PDF

다양한 고장조건에서 154kV 지중송전케이블 시스유기전압해석에 관한 연구 (A Study on the Analysis of Induced Voltage of Sheath on 154kV Transmission Power Cable in Multi Fault Cases)

  • 이준성;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1179-1181
    • /
    • 1998
  • This paper describes the induced voltage of sheath on 154kV transmission power cable in multi fault states. Simulation was carried out to obtain the induced voltage of sheath according to change of, fault angle and grounding resistance using EMTP. Modeling of cable system is also established in EMTP to analyze. The simulation results can be useful reference to design cable system in power system.

  • PDF

Power Reflection and Transmission Coefficients for Meander-Line Polarizers with a Chiral Slab

  • Delihacioglu, Kemal;Uckun, Savas
    • ETRI Journal
    • /
    • 제25권1호
    • /
    • pp.41-48
    • /
    • 2003
  • This paper presents a theoretical investigation of power reflection and transmission coefficients for a meander-line polarizer placed periodically on a chiral slab. It is assumed that a linearly polarized transverse magnetic wave is incident on a chiral slab from the air region. In the analysis, we derive the electric and magnetic fields in the modal form in the air and chiral regions. We obtain power reflection and transmission coefficients in a straightforward manner after matching the tangential components of the electric and magnetic fields at the boundaries. We present numerical results for the power reflection and transmission coefficients versus frequency and incident angle for different values of the chirality admittance. A meander-line polarizer placed on a dielectric slab can convert a linearly polarized wave to a circularly polarized wave. The design parameters for a meander-line polarizer are the dimensions of the meander-line and the values of the dielectric slab. Replacing a dielectric slab with a chiral slab introduces a new independent parameter which controls the wave polarization.

  • PDF

Resonant Transmission through Slits in a Cavity inside a Thin Conducting Plane

  • Lee, Jong-Ig;Cho, Young-Ki
    • Journal of electromagnetic engineering and science
    • /
    • 제10권3호
    • /
    • pp.127-131
    • /
    • 2010
  • In this paper, the problem of electromagnetic transmission via slits in a cavity inside a conducting screen of finite thickness has been considered in the case that the transverse electric(to the slit axis) polarized plane wave is incident on a slit. The problem is solved numerically by the method of moments and the results are compared with those obtained from an equivalent circuit suitable for a case in which the slit width is infinite and the structure is modified to the two partially overlapped conducting planes. It is observed that when the cavity is resonated, the effective slit width reaches its maximum value of $1/\pi$ wavelengths, irrespective of the actual slit width and the incidence angle. When the thickness of the conducting plane is much smaller than the wavelength, the numerical results for the effective slit width(or transmission width) agree well with those obtained from the equivalent circuit, even though the slit is as narrow as the thickness of the conducting plane.

A Metamodeling Approach for Leader Progression Model-based Shielding Failure Rate Calculation of Transmission Lines Using Artificial Neural Networks

  • Tavakoli, Mohammad Reza Bank;Vahidi, Behrooz
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.760-768
    • /
    • 2011
  • The performance of transmission lines and its shielding design during a lightning phenomenon are quite essential in the maintenance of a reliable power supply to consumers. The leader progression model, as an advanced approach, has been recently developed to calculate the shielding failure rate (SFR) of transmission lines using geometrical data and physical behavior of upward and downward lightning leaders. However, such method is quite time consuming. In the present paper, an effective method that utilizes artificial neural networks (ANNs) to create a metamodel for calculating the SFR of a transmission line based on shielding angle and height is introduced. The results of investigations on a real case study reveal that, through proper selection of an ANN structure and good training, the ANN prediction is very close to the result of the detailed simulation, whereas the Processing time is by far lower than that of the detailed model.

구형 마이크로스트립 패치 배열을 이용한 진행파 안테나의 특성 해석에 관한 연구 (Analysis of traveling wave antenna using rectangular microstip patch array)

  • 안광진;윤상원;장익수
    • 전자공학회논문지A
    • /
    • 제31A권10호
    • /
    • pp.31-38
    • /
    • 1994
  • In this paper, the leaky wave readiation characteristics of a microstrip rectangular patch array is presented. The reflection and transmission characteristics are analyzed using the equivalent transmission line method. Since the leaky wave is generated from the periodic array, using the Floquet'theorem, leaky wave frequency range is predicted and confirmed by the measured reflection and transmission characterstics of the array. A 17 element microstrip patch array at X-Band is designed and tested. Teh scattering Characteristics show good agreement woth those obtained from the equivalent transmission line analysis. The radiatio characteristics at 10GHz using this method show about 3${\circ}$ shift in main lobe angle compared with measured results.

  • PDF

UPFC가 계통에 미치는 영향을 선로정수 G, B의 함수로 표현한 새로운 UPFC 정태 해석모델 개발 (The Development of New UPFG Steady-State Model using Transmission Line Constant G. B)

  • 전동훈;김태균;추진부;김건중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1167-1169
    • /
    • 1999
  • This paper presents the new unified power flow controller(UPFC) load flow algorithm using UPFC transmission line constant model. The UPFC transmission line constant model represents a function of transmission line constant(G.B) UPFC's effect in power system. It can easily be incorporated in a load flow program. The algorithm is suited for monitoring the power system state as well as determining the magnitude and Phase angle of UPFC serial voltage source.

  • PDF

전달각을 고려한 조향기구의 최적합성 (Optimal Synthesis of Steering Mechanisms Considering Transmission Angles)

  • 박종근
    • 한국기계가공학회지
    • /
    • 제11권1호
    • /
    • pp.68-75
    • /
    • 2012
  • In this study, the optimal synthesis of planar steering mechanisms for vehicles is studied. The author minimized the steering error between two front wheels subject to the constraints of transmission angles. Nonlinear programming methods such as BFGS method and golden section search method are used for this optimization. As numerical examples, Ackermann's steering mechanism, 6-link and 10-link planar mechanism are adopted to check the usefulness of this method. Consequently, among the three optimized mechanisms, 10-link planar one conducts far more accurate performance subject to tight constraints of transmission angles.

외부 전자파의 입사방향에 대한 각진 두 스트립으로 구성된 전송선의 반응, II:등가구조의 모드해석 (Response of Angled two-Strip Transmission Lines to the Incident Angle of an External Electromagnetic Field, II : Modal Analysis on an Equivalent Structure)

  • 홍성용;김세윤;나정웅
    • 한국전자파학회지:전자파기술
    • /
    • 제4권1호
    • /
    • pp.3-9
    • /
    • 1993
  • 각진 두 스트립으로 된 전송선의 전자파 결합에 대한 새로운 해석 방법을 개발하였다. 이 방법은 먼저 원통형 전송선벙정식을 해석적으로 푼다음, 관련 변수들의 값을 등가구조인 각진 두 평판으로된 전송선을 따라 원통형 TEM 모드가 유지되도록 조정한다. 이러한 방법으로 구한 해석적인 형태의 해는 회로개념의 방법으로 구한 수치계산값과 거의 일치함을 보였다.

  • PDF