• 제목/요약/키워드: Transient Operation

검색결과 803건 처리시간 0.028초

영구자석 동기모터 진동 및 과전류 저감을 위한 능동단락회로 제어 기법 (Active Short Circuit Control Method to Reduce Overcurrent and Oscillation Current in PMSM)

  • 최종원;김윤재
    • 전력전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.339-347
    • /
    • 2022
  • This study proposes the mitigation method for overcurrent and oscillation motor current in an active short-circuit operation. This operation is attracting attention as the safe state of electric vehicle traction inverters. However, the active short-circuit operation generates oscillation and overcurrent of motor currents during a transient state. The proposed method uses two different safe states in PMSM, such as active short circuit and freewheeling. The active short circuit is used for safe state in a steady state. To reduce the overshoot and oscillation, a freewheeling state is injected between active short-circuit operation by comparing the motor phase current with an analytically calculated steady-state motor current. Freewheeling state is only used in a transient state. The performance is demonstrated through simulations and experimental results. The peak current of the motor was reduced from 52 A to 40 A, and oscillation time was reduced.

Measurement of Transient Electric Field Emission from a 245 kV Gas Insulated Substation Model during Switching

  • Rao, M. Mohana;Thomas, M. Joy;Singh, B.P.
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.306-311
    • /
    • 2007
  • The transient fields generated during switching operations in a Gas Insulated Substation (GIS) are associated with high frequency components in the order of few tens of MHz. These transient fields leak into the external environment of the gas-insulated equipment and can interfere with the nearby electronics. Measurements of the transient fields are thus required to characterise the interference caused by switching phenomena in such substations. In view of the above, E-field emission measurement during a switching operation has been carried out for a 245 kV GIS model, using a resonant dipole antenna and D-dot sensor. The characteristics of the E-fields i.e., frequency spectra and their levels have been analysed and are reported in the paper. Suitability of the measurements has been confirmed by comparing frequency spectra of the measured and computed transient fields.

석유 시추선 전력 계통의 과도 안정도 해석 (Analysis on transient stability for drilling rigs power system)

  • 김윤식;김철호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1119-1124
    • /
    • 2014
  • 본 논문은 석유시추선의 전력 계통 시스템의 비상시 전력 계통 해석에 대하여 기술하였다. 특히 석유시추선의 추진부하와 발전기의 탈락으로 인해 발생하는 전력계통 시스템에 미치는 영향을 검토하였다. 또한 고정 여자방식과 조속기의 제어 변수를 조정하여 임의의 사고 전후 정상상태로의 복귀까지 과도 안정도 해석으로 전력계통에 나타나는 현상을 관찰하였다. 전력계통 설계와 해석 및 과도 현상해석 프로그램인 ETAP(Electrical Transient Analysis Program)을 사용하였으며, 수치해석의 결과를 도출하여 그 특성을 분석하였다.

345[kV] 100[MVA] STATCOM 과도해석 모델 개발 및 동특성 분석 (The Development of Transient Analysis Model and Performace Analysis of 345[kV] 100[MVA] STATCOM)

  • 윤종수
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.28-34
    • /
    • 2011
  • This paper describes the development of the transient analysis model of 345[kV] 100[MVA] STATCOM and the result of the performance analysis. The Korea power utility company, KEPCO began a commercial operation of a 100[MVA] STATCOM(Static synchronous COMpensator) at 345[kV] Migeum substation in Seoul. In order to operate a new control device like STATCOM to the power system, suitable transient model is needed. Therfore, Korea Electric Power Coporation(KEPCO) developed a transient analysis models using EMTDC/PSCAD. The development of this transient analysis model is based on the actual STATCOM S/W algorithm and H/W specification that was provided by its manufacture. Through this model, the transient/dynamic performance of STATCOM at Migeum substation can be analyzed.

MNSR transient analysis using the RELAP5/Mod3.2 code

  • Dawahra, S.;Khattab, K.;Alhabit, F.
    • Nuclear Engineering and Technology
    • /
    • 제52권9호
    • /
    • pp.1990-1997
    • /
    • 2020
  • To support the safe operation of the Miniature Neutron Source Reactor (MNSR), a thermo-hydraulic transient model using the RELAP5/Mod3.2 code was simulated. The model was verified by comparing the results with the measured and the previously calculated data. The comparisons consisted of comparing the MNSR parameters under normal constant power operation and reactivity insertion transients. Reactivity Insertion Accident (RIA) for three different initial reactivity values of 3.6, 6.0, and 6.53 mk have been simulated. The calculated peaks of the reactor power, fuel, clad and coolant temperatures in hot channel were calculated in this model. The reactor power peaks were: 103 kW at 240 s, 174 kW at 160 s and 195 kW at 140 s, respectively. The fuel temperature reached its maximum value of 116 ℃ at 240 s, 124 ℃ at 160 s and 126 ℃ at 140 s respectively. These calculation results ensured the high inherently safety features of the MNSR under all phases of the RIAs.

안정도 지수와 에너지 마진을 이용한 불안정 발전기의 clustering 법 (A Novel Method for Clustering Critical Generator by using Stability Indices and Energy Margin)

  • 장동환;정연재;전영환;남해곤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권9호
    • /
    • pp.441-448
    • /
    • 2005
  • On-line dynamic security assessment is becoming more and more important for the stable operation of power systems as load level increases. The necessity is getting apparent under Electricity Market environments, as operation of power system is exposed to more various operating conditions. For on-line dynamic security assessment, fast transient stability analysis tool is required for contingency selection. The TEF(Transient Energy Function) method is a good candidate for this purpose. The clustering of critical generators is crucial for the precise and fast calculation of energy margin. In this paper, we propose a new method for fast decision of mode of instability by using stability indices. Case study shows very promising results.

원자로 보호계통 캐비닛의 동해석과 구조 안전성 평가 (Dynamic Analysis and Structural Safety Evaluation of the Cabinet of a Reactor Safety System)

  • 이부윤;조정래;김원진;정동관;손재율
    • 한국정밀공학회지
    • /
    • 제22권12호
    • /
    • pp.131-140
    • /
    • 2005
  • Responses of the cabinet of the reactor safety system under seismic leadings are analyzed, its dynamic characteristics and structural reliability being evaluated. Analyzed natural frequencies are compared with those measured from a resonance test. Structural safety of the cabinet is evaluated in consideration of the required response spectrums of the operation-base and safe-shutdown earthquakes. Transient responses of the cabinet are analyzed with input ground acceleration measured during the seismic test, accelerations being extracted at the locations of the main internal parts. The transient responses are compared with those from the seismic test, favorable results being shown.

TFT-LCD 생산공장 내 유틸리티 가동으로 인한 정밀장비 과도진동 현상 및 평가 (An Analysis and Assessment of Transient Vibration Phenomenon for Precision Equipment Due to Adjacent Utility Operation in TFT-LCD Fab)

  • 백재호;이홍기;손성완;전종균
    • 한국소음진동공학회논문집
    • /
    • 제17권8호
    • /
    • pp.726-735
    • /
    • 2007
  • Inside the factory buildings of aprecision industry (which produces semiconductors or TFT-LCD), thousands of vibration-sensitive precision equipments operate in the clean rooms. Various utility equipments that are installed around them for proper operation cause various sources of noise and of vibration to exist inside the clean rooms and thus deteriorate the noise and the vibration environment within. In this study, we check if the existing transient vibration phenomenon is caused by the vibrations that arise from operating the utility installed near these equipments; compare and evaluate the vibration criteria of precision equipments regarding the transient vibration phenomenon; and check the efficiency of these criteria.

과도응답 해석에 의한 전자레인지 도어 프레임의 비틀림 변형 평가 (Evaluation of Twisting Deformation of the Door Frame of a Microwave Oven by Transient Response Analysis)

  • 구진영;이부윤
    • 대한기계학회논문집A
    • /
    • 제29권9호
    • /
    • pp.1282-1288
    • /
    • 2005
  • This research has been motivated by the need to minimize possible leakage of microwave when one opens the door during operation of the microwave oven. An explicit finite element program is used to analyze the transient response the door of the oven under door-opening condition. Operation of the micro switch which plays an important role to hun off the power is simulated on the basis of the response of the latch. Using the results of the analysis, twisting deformation of the door frame is defined and evaluated.

Electric power system design and analysis for FLNG vessel

  • Lee, Geunbo;Jang, Jaehyeoung;Lyu, Sungkak;Yu, Jinyeol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.573-580
    • /
    • 2014
  • The electrical reliability of the power generation and distribution system of Floating Liquefied Natural Gas vessels has been analyzed according to the operating modes using Electrical Transient Analysis Program in this paper. Electricity is used for the topside processes, cargo pumps for off-loading, thrusters for heading control and marine equipment. It is very important to improve the safety, efficiency, and stability of the electrical power system for successful operation. The voltage variation of the high and the low voltage bus shall be within the primitive limitation range at normal operation loads both in steady state and in the transient state. The power system was simulated and compared with class rule for design verification.