Dynamic Analysis and Structural Safety Evaluation of the Cabinet of a Reactor Safety System |
Lee, Boo-Youn
(계명대학교 기계자동차공학부)
Cho, Chung-Rae (계명대학교 대학원 기계공학과) Kim, Won-Jin (계명대학교 기계자동차공학부) Jeong, Dong-Gwan (두산중공업(주) 기술연구원) Shon, Jae-Youl (씨아이이에스대구(주)) |
1 | Regulatory Guide 1.61, 'Damping Values for Seismic Design of Nuclear Power Plants,' U.S. Atomic Energy Commission, 1973 |
2 | Regulatory Guide 1.92, 'Combination of Modes and Spatial Components in Seismic Response Analysis,' U.S. Atomic Energy Commission, 1974 |
3 | Regulatory Guide 1.29, 'Seismic Design Classification,' U.S. Nuclear Regulatory Commission, 1978 |
4 | Regulatory Guide 1.222, 'Development of Floor Design Response Spectra for Seismic Design of Floor-Supported Equipment or Components,' U.S. Nuclear Regulatory Commission, 1978 |
5 | Regulatory Guide 1.100, 'Seismic Qualification of Electric and mechanical Equipment for Nuclear Power Plants,' U.S. Nuclear Regulatory Commission, 1988 |
6 | ANSI/IEEE SID 344-1987, 'IEEE Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations,' The Institute of Electrical and Electronics Engineers Inc, 1987 |
7 | Joe, Y. H. and Park, H. G., 'Modal Testing of Seismic Monitoring System Cabinet of Nuclear Power Plant,' Journal of the Korean Society of Civil Engineers, Vol. 19, No.2, pp. 449-457, 1999 |
8 | ANSYS, 'User's Manual,' Revision 6.2, ANSYS Inc., 2002 |
9 | Yang, B. S. and Kim, Y. H., 'Seismic Response Analysis of Steam Turbine-Gnerator Rotor System(1st Report, In Case of Rotor-Bearing System only),' Journal of KSNVE, Vol. 9, No.3, pp. 554-564, 1999 과학기술학회마을 |
10 | Byeon, H. S. and Lee, J. K., 'Seismic Qualification of the Main Control Board for Nuclear Power Plant,' Journal of KSNVE, Vol. 12, No. 11, pp. 856-863, 2002 과학기술학회마을 DOI |
11 | Mok, J. I. and Seong, P. H., 'Optimal Inspection Periods of Safety System of Wolsung Nuclear Power Plant Unit I with Human Error Consideration,' Journal of the Korean Nuclear Society, Vol. 26, No.1, pp. 9-19, 1994 과학기술학회마을 |
12 | Lee, J. K., Kim, J. Y. and Rhee, H. N., 'Seismic Qualification of the Air Cleaning Units for Nuclear Power Plants Ulchin 5&6,' Transactions of the KSME A, Vol. 26, No.7, pp. 1376-1383, 2002 |
13 | Lee, J. H. and Chang, S. H., 'Improvement of Pressurizer PROV System through Micro-Computer and PRA,' Journal of the Korean Nuclear Society, Vol. 17, No.4, pp. 302-317, 1985 과학기술학회마을 |
14 | Auh, G. S., Hwang, D. H. and Kim, S. H., 'A Steady-State Margin Comparison between Analog and Digital Protection Systems,' Journal of the Korean Nuclear Society, Vol. 22, No.1, pp. 45-58, 1990 과학기술학회마을 |
15 | The Enforcement Ordinance of Law of Atomic Energy, 1997 |
16 | Lee, J. K., Kim, J. Y., Chung, P. J. and Chung, J. H., 'Seismic Qualification of the Air Conditioning Equipment for Nuclear Power Plant,' Journal of KSNVE, Vol. 9, No.3, pp. 535-543, 1999 과학기술학회마을 |
17 | Regulatory Guide 1.60, 'Design Response Spectra for Seismic design of Nuclear Power plants,' U.S. Atomic Energy Commission, 1973 |