• 제목/요약/키워드: Transformer leakage inductance

검색결과 157건 처리시간 0.027초

고주파 트랜스포머의 권선기법 따른 손실특성 (Power Loss Characteristics according to Winding Method of High Frequency Transformer)

  • 김일남;윤신용;이공희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.49-51
    • /
    • 2004
  • This paper researched the power loss characteristics according to winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM software. The ferrite core model for analysis be used the EE type. Transformer model objected type applied to flyback converter. Therefore, analysis result was obtained the many parameter of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

  • PDF

권선구조에 따른 IPT transformer 해석 (The analysis of IPT transformer by winding structures)

  • 한경희;이병송;권삼영;박현준;백수현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.916-921
    • /
    • 2007
  • In this paper, the inductive power collector using electromagnetic induction for vehicle such as the electric railway vehicle system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The inductive power of secondary part is related to amount of linked flux to secondary part by the length of air-gap, which is expected by such a system parameter as mutual inductance. This paper will study for the transfer characteristic of power from input to output and equation including mutual inductance. And also, effect of leakage inductance variation of inductive power collector according to structure of winding was considered.

  • PDF

퀜치시 초전도 변압기의 최대온도에 철심이 미치는 영향 (Iron Core Effects on Maximum Temperature Rise of Superconducting Transformer during Quench)

  • 나완수;주진호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권1호
    • /
    • pp.7-12
    • /
    • 1999
  • In this paper, the analytical results on the maximum temperature rise estimation, taking account of the magnetizing current, are presented. Magnetizing current effects are considered for the maximum temperature rise estimation during quenches. By introducing the first order model of the infinite solenoids, we calculate the magnetizing and leakage inductances of the coaxial-wound-superconducting transformers. As the permeability of the transformer core increases, so does the magnetizing inductance, while the leakage inductances and the magnetizing current of the transformer go down. These varying permeability effects on maximum temperature rise estimation is applied to the superconducting transformers, of which specifications have already been published. The calculated results showed sufficient margins to the thermal damage.

  • PDF

누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구 (A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary)

  • 정현주;이동훈;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권9호
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

High-Efficiency Non-contact Power Supply System

  • Zheng, Bin;Kwan, Dae-Hwan;Lee, Dae-Sik
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.233-235
    • /
    • 2005
  • Non-contact power supply (NCPS), as a clean and safe energy supply concept has been applying wildly. Comparing with the conventional transformer the non-contact transformer has a large air gap between the long primary winding and the secondary winding. Due to it, the non-contact transformer has increased leakage inductance and reduced magnetizing inductance. So the high frequency series resonant converter has been widly used on the non-contact power supply system for transferring the primary power to the secondary one, from what a high influence voltage can be gained on the secondry coil even though the large air gap exists. However, it still has the disadvantages of the load sensitive voltage gain characteristics when load is changing. In this paper, we propose a fuzzy logic controller to adjust the frequency of the inverter to track the resonat which is changing when the load is change.

  • PDF

A Hybrid DC/DC Converter for EV OBCs Using Full-bridge and Resonant Converters with a Single Transformer

  • Hassan, Najam ul;Kim, Yoon-Jae;Han, Byung-Moon;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.11-19
    • /
    • 2017
  • This paper proposes a dc/dc converter for electric vehicle onboard chargers using a secondary resonant tank. To attain soft switching characteristics, such as zero voltage switching, magnetizing inductance has been used at the primary side of the transformer. The leakage inductance of the transformer is used as a resonant inductor on the secondary side to avoid the use of a separate inductor as resonance. The proposed converter is applicable for a wide load range. A 6.6KW prototype has been implemented for a wide range of load variations (250V, 330V, 360V, and 413V). A maximum efficiency of 97.4% is achieved at 413V.

High Power Density, High Frequency, and High Voltage Pulse Transformer

  • Kim, S.C.;Jeong, S.H.;Nam, S.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권4호
    • /
    • pp.180-184
    • /
    • 2001
  • The high operation frequency mainly reduces transformer volume in the power supply. A high frequency and high voltage pulse transformer is designed, fabricated, and tested. Switching frequency of the transformer is 100 kHz. Input and output voltages of the transformer are 250 V and 4 kV, respectively. Normal operation power of the transformer is 3 kW. Maximum volume of the transformer is 400 $cm^3$. The power density is thus 7.5 W/$cm^3$. The transformer will be installed in a metal box that has nominal operation temperature of 85 degree centigrade. The transformer and other high voltage components in the box will be molded with Silicon RTV(Room Temperature Vulcaniza) that has a very low thermal conductivity. Procedure of design and test results are discussed. Analytical as well as experimental results of varous paramters such as transformer loss, leakage inductance, distributed capacitance are also discussed. In addition, thermal analysis results from ANSYS code for three different operation conditions are discussed.

  • PDF

유한요소법을 이용한 전기기기의 누설인덕턴스 계산 (The Calculation Method of Leakage Inductances in Electrical Machines Using F.E.M.)

  • 김형석;최명준;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.18-20
    • /
    • 1995
  • In this paper we presented a calculation method of leakage inductance in electrical machines. For its accurate calculation the finite element method is applied to the analysis of magnetic field distribution. The self and mutual inductances are derived using the results of the magnetic field analysis and the leakage inductance is easily obtained from these inductances. As numerical examples, we tread a single phase transformer and a rotor slot model of induction motor. In the finite element analysis we used the 2D linear magnetostatic formulation with the first-order triangular element.

  • PDF

저손실 자심재료를 이용한 평면변압기 제조 및 동작특성 (Manufacture and Characteristics of the Planar Transformer using low power loss magnetic materials)

  • 이해연;허정섭;김현식;박혜영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.19-22
    • /
    • 2004
  • The resonant planar transformer, which had power capacity of 300 W, input voltage of 220 V, output voltage of 15 V, and switching frequency of 500 kHz, was designed and manufactured by using the planar core with large effective area and the flat copper lead frames for miniaturization and high efficiency of the switching mode power supply (SMPS). As well as, a resonant converter equipped with the above mentioned planar transformer was manufactured and electromagnetic characteristics were investigated. The numerical value of turns for 1st and 2nd winding were 12 and 2 respectively. The self inductance of 1st winding was 33.2 ${\mu}H$, very low leakage inductance of 1.27 ${\mu}H$, and the coupling factor of 0.98 were obtained at switching frequency of 300 kHz. The high efficiency of 88.21 % for the SMPS equipped with planar transformer was obtained at power capacity of 300 W.

  • PDF

소프트 스위칭 기법을 이용한 1단 PFC-flyback 컨버터 (The Study on the One-stage PFC-flyback Converter using the Soft Switching Technique)

  • 이상혁;황정구;박성준
    • 전력전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.263-269
    • /
    • 2013
  • The flyback converter has been applied widely in isolated DC/DC power converters because this converters employ a single MOSFET switch. The leakage inductance should be minimized for high efficiency of flyback converter. but in reality, it is very difficult. Namely, The Snubber circuit is essential to recover the leakage inductance stored energy when the switch is turn off. Flyback Converter typically operates in DCM mode and when switch is turn off in hard switching, this hard switching action results in a high power losses and switching stresses. In order to overcome these problems, a novel soft switching flyback converter using resonant snubber circuit is proposed in this paper. The resonant snubber circuit is composed of the transformer leakage inductance and a capacitor. To verify and confirm the proposed resonant snubber circuit, PSIM simulation and hardware prototype are implemented. Simulation and Experimental results indicate that the proposed resonant snubber circuit is effective.