Power Loss Characteristics according to Winding Method of High Frequency Transformer

고주파 트랜스포머의 권선기법 따른 손실특성

  • Published : 2004.07.01

Abstract

This paper researched the power loss characteristics according to winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM software. The ferrite core model for analysis be used the EE type. Transformer model objected type applied to flyback converter. Therefore, analysis result was obtained the many parameter of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.