• Title/Summary/Keyword: Transformer Substation

Search Result 159, Processing Time 0.023 seconds

Improvement Method of SVR Control in Power Distribution System Interconnected Distributed Generator (분산전원이 연계된 배전계통에 있어서 선로전압조정장치(SVR)의 전압제어 개선방안)

  • Lee, Hyun-Ok;Huh, Jae-Sun;Kim, Byung-Ki;Rho, Dae-Seok;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.224-229
    • /
    • 2014
  • This paper presents the novel voltage control method in power distribution system with distributed generators. The voltage in distribution systems is regulated by Under Load Tap Changer(ULTC) of substation and pole transformer of primary feeders. Recently, Step Voltage Regulator(SVR) is getting located at distribution feeders to regulate effectively voltage of primary feeders. But the effectiveness of SVR decreases due to independent operation between SVR and ULTC, and also the existing Line Drop Compensator(LDC) method considering the distributed generators may be not able to regulate the proper voltage in a permissible range. Thus, this paper presents a optimal voltage control algorithm of SVR by using the secondary voltage data of main transformer in substation.

A Study on the Development of a Silencer and Noise Reduce for M.Tr Room (주변압기실의 소음저감 및 소음기 개발에 관한 연구)

  • Kim, Young-Dal
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.111-118
    • /
    • 2006
  • Relatively high noise emitted from Transformers of in-door-substation in urban area has become the target of public complaints and the frequency is on the rise in these days due to an extension of transformer installations and new establishment of substations. The noise consist of harmonics of a specific frequency of the twice of the electricity frequency(60[Hz]), which is hard to control by using the general sound proofing techniques. In this work, several effective methods were discussed for reducing the noise from a transformer, which is transmitted through explosion preventing shutter and air tunnels. By applying to the actual site, the effects of the methods were verified.

A New Volt/Var Control of Substation for Distribution Volt/Var Regulation (배전계통 전압/무효전력조정을 위한 새로운 전압/무효전력제어 방식)

  • Choi, Joon-Ho;Kim, Jae-Chul;Son, Hag-Sig;Im, Tae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.285-288
    • /
    • 2001
  • In this paper we proposed the on line volt/var control schemes of the load Tap Changer (LTC) transformer and shunt capacitor bank for distribution volt/var regulation. In the existing volt/var control of the distribution substation, the voltage of feeders and var of distribution systems is mainly controlled by the LTC transformer tap position and on/off status of the shunt capacitor. The LTC and shunt capacitor bank has discrete operation characteristics and therefore it is very difficult to control volt/var at the distribution networks within the satisfactory levels. Also there is limitation of the operation times of the LTC and shunt capacitor bank because it is affects on their functional lifetime. The proposed volt/var control algorithm determine an optimal tap position of LTC and on/off status of shunt capacitors at a distribution network with the multiple feeders. The mathematical equations of the proposed method are introduced. Simple case study was performed to verify the effectiveness of the proposed method.

  • PDF

A Study on the Effective Downscaling Methodology for Design of a Micro Smart Grid Simulator

  • Ko, Yun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1425-1437
    • /
    • 2018
  • In this paper, a methodology was proposed to reduce the electrical level and spatial size of the smart grid with distributed generations (DGs) to a scale in which the electrical phenomena and control strategies for disturbances on the smart grid could be safely and freely experimented and observed. Based on the design methodology, a micro smart grid simulator with a substation transformer capacity of 190VA, voltage level of 19V, maximum breaking current of 20A and size of $2{\times}2m^2$ was designed by reducing the substation transformer capacity of 45MVA, voltage level of 23kV and area of $2{\times}2km^2$ of the smart grid to over one thousandth, and also reducing the maximum breaking current of 12kA of the smart grid to 1/600. It was verified that the proposed design methodology and designed micro smart grid simulator were very effective by identifying how all of the fault currents are limited to within the maximum breaking current of 20A, and by confirming that the maximum error between the fault currents obtained from the fault analysis method and the simulation method is within 1.8% through the EMTP-RV simulation results to the micro smart grid simulator model.

Fault Diagnosis of Power Transformer by FCM and Euclidean Based Distance Measure (FCM과 유클리디언 기반 거리유사도에 의한 전력용 변압기의 고장진단)

  • Lee, Dae-Jong;Lee, Jong-Pil;Ji, Pyeong-Shik;Lim, Jae-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1007-1016
    • /
    • 2007
  • In power system, substation facilities have become too complex and larger according to an extended power system. Also, customers require the high quality of electrical power system. However, some facilities become old and often break down unexpectedly. The unexpected failure may cause a break in power system and loss of profits. Therefore it is important to prevent abrupt faults by monitoring the condition of power systems. Among the various power facilities, power transformers play an important role in the transmission and distribution systems. In this research, we develop intelligent diagnosis technique for predicting faults of power transformer by FCM(Fuzzy c-means) and Euclidean based distance measure. The proposed technique make it possible to measures the possibility and degree of aging as well as the faults occurred in transformer. To demonstrate the validity of proposed method, various experiments are performed and their results are presented.

Development of a Silencer for an Acoustic Enclosure of a Large Transformer (대형 변압기의 밀폐장치용 소음기 개발)

  • Lee, Jun-Shin;Lee, Wook-Ryun;Lee, Tae-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.786-789
    • /
    • 2005
  • An acoustic total or partial enclosure is widely used to reduce the sound pressure level propagating from a noise source. However, the performance of the acoustic enclosure is decreased by its inherent limitations such as temperature rise or acoustic pressure build up inside the enclosed acoustic field. In general, a silencer is installed to overcome these limitations, for large amount of air can be exchanged through the silencers. In this reason, a parallel baffle type duct silencer with acoustic resonators is studied to reduce the transmitted noise from a transformer. In this silencer, the high frequency components of the transmitted noise over 360Hz are effectively absorbed by the parallel baffles and the other ones, 120 and 240 Hz, are reduced due to the presence of Helmholtz resonators. Large sound attenuation is achieved by applying the sound resonating barrier to the large transformers in a substation.

  • PDF

The analysis for flooding prevention countermeasures of Electrical facility and Transformer Vault on Foreign (국외 수변전실 및 지상 전력기기 침수방지 대책에 관한 조사연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Jean, Hyun-Jae;Bae, Suk-Myong;Lee, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.305-307
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-tying shore by heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment (Pad-mounted Transformer and Switch). So we research the flooding prevention countermeasures of electrical facility and Transformer Vault on Foreign. We conform the site facility and related regulation for flooding prevention on Foreign.

  • PDF

Establishment of Diagnostic Criteria in the Preventive Diagnostic System for the Power Transformer (전력용 변압기 예방진단새스템의 진단기준치 실정)

  • Kweon Dong-Jin;Koo Kyo-Sun;Kwak Joo-Sik;Woo Jung-Wook;Kang Yeon-Wook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.449-456
    • /
    • 2005
  • The preventive diagnostic technique prevents transformers from power failure through giving alarm and observing transformers in service. And it helps to establish the plan for optimum maintenance of the transformer as well as to find location or cause of fault using accumulated data. Data detection and experience of the preventive diagnostic system need to establish the preventive diagnostic algorithm regarding interrelationship between detected data and deterioration of equipment. Therefore in-depth analysis about the preventive diagnosis system is required. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Techniques for component sensors of the preventive diagnosis system were settled but diagnosis algorithm, diagnostic criteria and practical use of accumulated data are not yet established. This paper, to build up the base of preventive diagnostic algorithm for the Power transformer. investigated the preventive diagnostic criteria for the power transformer.

A Study on the Core Noise Reduction Techniques of Power Transformers (전력용 변압기 철심소음 저감기술에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Cho, Ik-Choon;Kim, Yoo-Hyun;Kim, Yung-Sig
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1962-1969
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint is increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation of the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated core noise reduction techniques to develope a low noise transformer. The techniques to reduce core noise of the transformer are application of high permeability grain oriented silicon sheets, decrease of magnetic flux density of core, application of 6step-lap core stacking method, improvement of core binding method(binding addition, band fixing) and application of rubber damper in oder to reduce transmission of core vibration, etc.

Aging Characteristics of Power Transformer Oil and Development of its Analysis using KOSM (전력용 변압기유의 열화 특성에 KSOM에 의한 분석기법 개발)

  • 임재윤;지평식;이종필;남상천;이승렬
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.56-63
    • /
    • 1999
  • In power system, substation facilities have become too complex and large according to extended power system. Also, some facilities becorre old and often break down unexpectedly. In order to improve the sectrity of transformer out of substation facilities, the development of diagnosis technique to transformer is very needed. In this paper, we developed a method to be analysis the origin and degree of aging by KSOM based on the dissolved gases in power transfonrer. KSOM can do topological mapping for the multi-dimensional pattern based on the dissolved gases to two dimensional plane. And potential possibility and degree of aging for nonna1 transfonrer are presented using the proposed quantitative criterion. Furtherrrore, the aging process of transfonrer is analyzed based on the proposed criterion to special transfonrer. To demonstrate the validity of peoposed method, case study is performed and its results are presented.sented.