• 제목/요약/키워드: Transformed image

검색결과 631건 처리시간 0.025초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

데크놀로지 미학으로서의 사진 (The Photography as Technological Aesthetics)

  • 진동선
    • 조형예술학연구
    • /
    • 제11권
    • /
    • pp.221-249
    • /
    • 2007
  • 오늘날 사진은 새로운 테크놀로지 형태인 디지털 이미지 프로세싱 앞에 심각한 정체성 위기와 존재론적 딜레마에 봉착했다. 사진은 그동안 우리에게 세상을 새롭게 바라보는 방법을 제공하고, 또 우리 스스로 주변을 돌아볼 수 있는 자각을 주었으며, 나아가 삶의 리얼리티의 본질을 재인식시키는데 크게 기여했다. 그런 사진의 기능이 오늘날 무력화되고 있다. 디지털 테크놀로지의 출현으로 사진은 더 이상 사실의 기록, 결백의 증거, 그리고 리얼리티의 거울로서 간주되지 않는다. 오히려 유희의 도구 혹은 우리가 사는 세계의 환영과 기쁨을 창조하는 수단으로 간주된다. 그러나, 디지털 테크놀로지의 출현은 이제 비로소 사진의 존재론적 당위성과 정체성의 문제를 냉정히 돌아보게 한다. 본 논고는 전자시뮬레이션 시대 새로운 이미지 생산의 첨병으로 등장한 디지털 이미지의 존재론적 측면을 규명하는데 있다. 이를 위해 인류의 첫 번째 프로그램 미학으로 말해지는 사진과 첨단테크놀로지 미학으로 말해지는 디지털 이미지와의 관계를 기계미학적 관점에서 살펴보려 한다. 특히 올드미디어(사진)와 뉴미디어(디지털) 사이에 갈등 구조를 자본주의 역사관과 물질적 관점에서 살펴보려 한다. 본 논고는 이를 위해 우선 사진의 정체성 위기와 존재론적 위협이 어디로부터 발현된 것인지를 살피고, 또 지금까지 생산된 매체 미학적 담론들이 어떤 비평적 쟁점 속에 놓였는지를 살피고자 한다. 특히 사진이 강점으로 여긴 존재론적 인덱스와 생성론적 텍스트에 주목하여 사진 재현의 기반인 사실적 기록, 명료한 증거, 그리고 기술적 정교성이 어떤 기계미학의 층위에 있는지를 디지털 이미지를 대척에 두고 분석하고자 한다. 그리하여 최근 일고 있는 사진의 죽음, 사진의 종말에 관한 담론들이 심각한 오류가 있음을 지적하고자 한다. 올드 테크놀로지로서 사진이 당면한 위기, 즉 현재 사진이 안고 있는 존재론적 위기(컴퓨터화 된 디지털 이미지 출현) 그리고 인식론적 위기(윤리, 지식, 가치관 등 급격한 문화 변동)는 매체미학의 본질상 당연한 위기임을 정당화하고자 한다. 본 논문은 이 같은 주장을 위하여 역사적으로 사진술이 어떤 생성과 소멸의 과정을 거쳤으며, 또 어떻게 지금의 디지털 이미지에 이르게 되었는지 테크놀로지 미학 안에서 자동생성주의로서 색인 이미지, 디지털 코드로서 수치 이미지의 생성, 기원, 본질 그리고 정체성을 규명하고자 한다. 특히 본 논고는 논지의 정당성을 위해 다양한 매체미학자들의 주의주장 및 이론적 쟁점을 분석하고자 한다. 또 분석틀을 통해서 테크놀로지 미학의 근간인 기계, 기술성을 바탕으로 한 사진의 생성적 측면과 문화 안에서 변형된 프로그램에 의해 창조되는 디지털 이미지의 변형적 측면의 본질을 파악하고자 한다. 이렇게 사진과 디지털 이미지의 양자의 비교를 통해서 테크놀로지 미학 안에서 올드 미디어(사진)와 뉴 미디어(디지털 이미지)의 자리바꿈은 정당한 것이라는 사실과, 이런 역설적인 구조야말로 기계, 기술을 바탕으로 삼는 테크놀로지 매체의 숙명성이라는 사실을 강조함으로써 논문의 정당성을 강화하고자 한다. 마지막으로 본 논고는 하나의 얼굴, 하나의 정체성으로 자리할 수 없다는 사실을 역사로서 확증하고, 또 사진에서 부동의 존재론과 인식론의 모습은 애초부터 불가능하다는 사실을 지적함으로써 오늘날 제기되고 있는 '사진의 죽음,' '사진의 종말'은 쟁점의 정당성에도 불구하고 매체미학의 역사를 간과하는 오도된 비평이라는 사실을 결론으로 도출하고자 한다.

  • PDF

실시간 응용을 위한 웨이블릿 변환 기반의 얼굴 검출 (Wavelet Transform-based Face Detection for Real-time Applications)

  • 송해진;고병철;변혜란
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제30권9호
    • /
    • pp.829-842
    • /
    • 2003
  • 최근 화상 회의, 화상 전화, 모바일 환경에서의 화상 통신, 얼굴 인식을 이용한 보안 시스템 등의 상업화에 힘입어 비디오에서의 얼굴 검출 및 추적 기술은 눈부신 발전을 이룩하였다. 또한, 얼굴 요소 검출은 요소 그 자체뿐 아니라 정화한 얼굴 영역 검출을 위한 필수 단계로서 중요한 연구 주제가 되고 있다. 그러나 영상에 나타난 복잡한 배경과 카메라 조작 및 조명에 의한 색상 왜곡 그리고 다양한 조명 조건 둥은 얼굴 검출 및 추적, 요소 검출에 있어 여전히 큰 장애가 되고 있다. 이에 따라, 본 논문에서는 실시간 화상 통신을 위한 새로운 얼굴 영역 검출 및 추적 알고리즘과 검출된 얼굴 영역에서 효과적으로 눈 영역을 검출할 수 있는 알고리즘을 제안한다. 제안하는 얼굴 검출 알고리즘은 복잡한 배경과 다양한 조명 조건에 관계없이 얼굴을 검출하고 추적하기 위해 웨이블릿 변환된 세 종류의 부 영역을 이용하여 얼굴 형판을 생성하고 웨이블릿 변환된 입력 영상과의 유사도를 측정하여 얼굴을 검출한다. 특히 다양한 조명 조건을 극복하기 위해 최소-최대 정규화와 히스토그램 평활화를 혼합 적용하여 매우 밝거나, 매우 어두운 영상에서의 얼굴 오 검출 및 놓침을 줄일 수 있었으며 세 가지 크기의 얼굴 형판을 이용함으로써 입력 영상에 존재하는 다양한 크기의 얼굴도 검출할 수 있었다. 또한 효과적인 얼굴 추적 알고리즘을 통해 다음 프레임에서의 얼굴 위치를 예측하고 예측된 얼굴 위치를 중심으로 탐색 영역을 정해 형판 정합을 수행함으로써 얼굴 검출률을 높이면서 수행 시간도 단축시킬 수 있었다. 수직, 수평방향 투영을 이용한 합리적인 눈 검출 알고리즘은 어두운 조명이나 부정확한 얼굴 영역에서도 만족스러운 결과를 보여주었다.26$이었으며, 점차 감소, 다시 증가하여 담금 10일에는 $3.42{\sim}3.69$이었다. 시험구별로는 KKR이 가장 낮았다. 총산은 담금 1일에 $0.29{\sim}0.82%$였으며 담금 6일에 $1.75{\sim}2.53%$로 최고값을 나타내었으며 그 후 감소하여 담금 10일에는 $1.61{\sim}2.34%$였다. 시험구간에는 KKR, SKR이 비교적 높은 값을 나타내었다. 무기질 함량은 발효기간이 경과할수록 증하였고 Ca는 $2.95{\sim}36.76$, Cu는 $0.01{\sim}0.14$, Fe는 $0.71{\sim}3.23$, K는 $110.89{\sim}517.33$, Mg는 $34.78{\sim}122.40$, Mn은 $0.56{\sim}5.98$, Na는 $0.19{\sim}14.36$, Zn은 $0.90{\sim}5.71ppm$을 나타내었으며, 시험구별로 보면 WNR, BNR구가 Na만 제외한 다른 무기성분 함량이 가장 높았다.O to reduce I/O cost by reusing data already present in the memory of other nodes. Finally, chunking and on-line compression mechanisms are included in both models. We demonstrate that we can obtain significantly high-performance

도시 군부대 이전 적지의 공원화 방향에 대한 시민인식 분석 - 의정부시 사례연구 - (A Study of the Analysis of Citizen's Awareness of the Transforming of a Former Military Site into Urban Park - With Special Reference to the City of Euijungbu -)

  • 맹치영;조세환
    • 한국조경학회지
    • /
    • 제37권2호
    • /
    • pp.62-69
    • /
    • 2009
  • 이 연구는 지식정보산업사회의 새로운 도시화의 새로운 양상으로 나타나고 있는 도시 내 군부대 이전 적지의 공원화에 대한 도시민의 인식을 분석함으로써 향후 도시 내 군부대 이전 적지의 공원화에 대한 타당성과 공원조성 방향을 모색해 보기 위한 목적으로 수행되었다. 본 연구는 도시재생 관점에서 이루어진 도시 내 이전 적지에 대한 공원화 해외 사례와 조성방향을 분석을 위해 문헌연구를 수행하였다. 또한, 군부대 이전 적지의 공원화에 대한 도시민의 인식을 분석하기 위해 우리나라 군부대 이전 적지의 대표적 도시인 의정부를 대상으로 2006년 $6{\sim}7$월에 설문조사하였으며, 연구 결과는 다음과 같다. 첫째, 도시 재생적 관점에서 도시의 쇠퇴지 및 이전 적지를 공원으로 조성한 사례는 파리의 라빌레트 공원과 토론트의 다운스 뷰 공원, 미국 어바인의 그레이트 공원 등을 들 수 있었다. 둘째, 이들 공원은 이전 적지를 문화, 교육, 상업 등의 용도와 복합화한 대형공원으로 조성하는 특색을 보이고 있었다. 셋째, 의정부시의 군부대 이전 적지의 공원화에 대한 시민들의 인식은 1) 공원은 도시생활환경 개선 용도를 우선으로 하되, 도시의 문화적 이미지 개선과 도시의 경제적 활성화를 위한 용도로 활용되기를 선호하는 것으로 나타났고, 2) 군부대 이전 적지의 공원화에 대한 시민들의 인식은 매우 선호하는 것으로 나타났으며, 특히, 이러한 공원화를 통해 도시경제 활성화에 대한 기대도가 높은 것으로 나타났다. 3) 의정부 시민은 이러한 공원이 특히, 문화적 용도로 활용되는 것을 선호하는 것으로 나타나는 반면 4) 이전 적지가 주거용지와 상업용지 전용으로 활용하는 것에 대해서는 비선호하는 것으로 나타났다. 이상의 연구 결과로 볼 때, 군부대 이전 적지 등 도시에 출현하는 새로운 유형의 토지이용은 경제, 사회, 환경, 심미성 등의 활성화를 제고하는 도시 재생적 관점에서 추진되어야 할 필요가 있으며, 특히 기존의 주거 또는 행정, 상업 등의 단일 용도의 토지이용보다는 공원과 상업, 문화 등 시민선호 용도와의 혼성을 통한 복합화된 공원으로 조성되어야 할 것으로 분석되었다.

$H_2^{15}O$ 양전자단층촬영술을 이용한 뇌기능 지도 작성(I): 통계적 파라메터 지도작성법 (Functional Brain Mapping Using $H_2^{15}O$ Positron Emission Tomography ( I ): Statistical Parametric Mapping Method)

  • 이동수;이재성;김경민;정준기;이명철
    • 대한핵의학회지
    • /
    • 제32권3호
    • /
    • pp.225-237
    • /
    • 1998
  • 목적: $H_2^{15}O$ 양전자단층촬영으로 작업기억을 조사할 때 뇌기능을 국소화한 뇌기능지도를 만들기 위해 동원되는 통계적 가정과 추론의 여러 방법을 해석하고 뇌활성화와 관련된 뇌기능 국소화 방법에 영향을 미치는 요소를 조사하였다. 대상 및 방법: 정상인 6명에 대하여 각각 대조과제, 언어성 작업기억 활성화과제 2종류, 시각적 작업기억 활성화과제 1종류를 수행시키며 뇌혈류 $H_2^{15}O$ PET 촬영을 시행하였다. SPM96 소프트웨어를 이용하여 각 영상과 표준지도의 뇌피질 경계가 일치 되도록 부분 선형적으로 변형하였으며 선형화한 비선형적 변형 방법으로 사람에 따라 나타나는 뇌피질 및 내부 구조의 미세한 차이를 제거하였다. 공간정규회된 영상들을 16mm의 FWHM을 갖는 가우시안 커널로 중첩적분하여 편평화하였다. 각 화소의 방사능 계수는 뇌피질전체 뇌혈류, 활성화에 의한 특정 효과, 여러 교란변수의 영향과 오차의 선형 결합으로 이루어진다는 일반선형모델을 가정하고 공분산분석 방법으로 전체 뇌혈류 차이를 제거하였다. 각 화소의 방사능 계수가 자극과 뇌활성화 작업에 상관없을 경우 평탄한 무작위 가우스장의 행동을 따른다고 가정하고 특정화소의 계수차이가 이 무작위장의 정상적인 교란 이상인지 검정하였다. 화소별 t 값을 Z 값으로 바꾸어 표현하고 가설검정 결과에 따라 화소, 덩어리, 화소 또는 덩어리의 차이가 얼마나 유의한지 제시하였다. 결합분석을 하여 여러 과제를 수행할 때 동시에 화소의 계수가 증가하는 곳을 찾았다. 각 화소의 Z 값을 3차원으로 렌더링한 표준지도와 투명유리뇌에 투사하여 활성화된 부위를 알아볼 수 있게 하였다. 결과: 피검자 모두 성공적으로 검사를 마쳤으며 대조 과제와 기억 과제를 수행하는 동안 피험자는 평균 95%를 맞췄다. 활성화된 덩어리의 개수는 언어성 기억과제 I에서 4개, 언어성 기억과제 II에서 9개, 시각적 기억과제에서 9개, 결합분석에서 6개였다. 언어성 기억과제에서는 주로 왼쪽 뇌가, 시각적 기억과제에서는 오른쪽 뇌가 활성화되었다. 결론: $H_2^{15}O$ 양전자 단층촬영술과 통계적 파라메터 지도작성법이 언어성 및 시각적 작업기억과 관련되어 활성화된 지 영역을 찾는데 유용하였다.

  • PDF

화소기반 형태분석 방법을 이용한 내측측두엽 간질환자의 회백질 부피/농도 감소평가; FDG PET과의 비교 (Voxel-based Morphometry (VBM) Based Assessment of Gray Matter Loss in Medial Temporal Lobe Epilepsy: Comparison with FDG PET)

  • 강혜진;이호영;이재성;강은주;이상건;장기현;이동수
    • 대한핵의학회지
    • /
    • 제38권1호
    • /
    • pp.30-40
    • /
    • 2004
  • 목적: 본 연구의 목적은 첫째, 내측 측두엽 간질환자의 MR 영상에 화소기반 형태분석방법(VBM)을 적용하여 회백질 부피감소를 보이는 영역을 뇌 전체를 관찰하여 찾아내고자 하였다. 둘째, 본 연구에서 적용된 VBM방법이 내측측두엽 간질환자의 간질병소의 편측성을 평가하기에 쓰일 수 있을지 조사하였다. MR영상으로 VBM 결과를 FDG PET의 SPM 분석결과와 비교하였다. 대상 및 방법: 12명의 좌측 내측측두엽 간질환자와 11명의 우측 내측측두엽 간질환자의 T1 강조영상을 각각 37명의 정상 대조군의 영상과 비교하였다. 모든 영상을 표준 뇌 표준판에 공간정합한 후, 평균영상을 생성하여 연구-특정적 뇌 표준판을 만들고 이 연구 측정적 표준판에 다시 비선형 공간정규화 하였다. 영상을 분할하여 회백질영상을 추출하고 변조한 후 편평화하였다. 환자군과 정상군의 차이를 SPM99를 이용하여 허위발견률을 기준으로 통계처리하였다. FDG PET 영상을 SPM을 이용하여 정상대조군 22명과 비교하였다. 결과: 좌측 내측측두엽 간질환자는 좌측의 해마와 편도체 영역에 회백질 부피/농도가 감소하였고, 뇌의 양측 소뇌, 전대상회, 방추상회의 부피/농도가 감소하였다. 우측 내측측두엽 간질환자는 우측 해마의 서 회백질이 감소하였다. 좌측 내측측두엽 간질은 좌측 측두엽과 시상 우측 내측측두엽간질 환자는 우측측두엽에 광범위한 부위에 FDG 섭취가 감소하였다. 결론: VBM 방법을 적용한 결과 간질원인 병소 해마와 해마주변영역에서 유의하게 회백질 부피/농도가 감소하였다. FDG PET SPM 분석에서 간질원인병소의 대사 감소를 찾을 수 있었던 것처럼, 이 연구에서 적용한 변조 VBM 방법은 내측측두엽 간질환자의 간질원인병소를 편측화할 수 있었고 내측측두엽을 제외한 다른 뇌영역의 해부학적 변화를 발견하는데 도움이 되었다. 이에 비하여 간질원인병소인 좌우측측두엽의 넓은 부위에 FDG 섭취가 감소하여 대조되었다.

성인 구개부 측모두부계측방사선 사진과 3D model의 골두께 비교 (Comparison of palatal bone thickness between 3D model and lateral cephalometric radiograph)

  • 장민국;이진우;차경석;정동화;이상민
    • 대한치과교정학회지
    • /
    • 제41권5호
    • /
    • pp.312-323
    • /
    • 2011
  • 본 연구는 동일한 환자에서 촬영한 측모두부계측방사선 사진과 전산화단층촬영 영상을 비교하여 미니 임플랜트 식립 시 측모두부계측방사선 사진을 통해 상악 구개부 골두께를 예측하기 위한 목적으로 시행되었다. 안모가 양호한 정상교합자 남녀 총 30명의 전산화단층촬영 영상을 3D model로 변환하고 측모두부계측방사선 사진과 동일부위의 골두께를 계측하기 위하여 프랑크프루트 평면에 대해 수직이고 상악 제2소구치와 제1대구치 인접면을 지나는 기준평면을 설정한다. 3D model에서 횡적으로 2 mm 간격으로 11개 부위의 구개부 골두께를 계측하고 측모두부계측방사선 사진과 비교하여 다음과 같은 결과를 얻었다. 3D model에서 골두께는 남녀 모두 정중구개부위에서 가장 컸고 측방으로 멀어질수록 작아지다가 남성는 측방 6 mm 여성는 측방 8 mm 부위에서 가장 최소값을 보인 후 다시 커지는 양상이 관찰되었다. 측모두부방사선 사진상 골두께는 남성이 $4.21{\pm}1.03mm$, 여성은 $2.71{\pm}1.62mm$로 남성이 여성보다 유의성 있게 컸다. 측모두부계측방사선 사진상 골두께와 3D model에서 횡적인 부위별로 측정한 골두께는 남성은 정중구개부와 측방 2 mm 부위를 제외한 나머지 부위에서 유의성 있는 상관관계를 보였고 여성은 모든 부위에서 유의성 있는 상관관계를 보였다. 또한 측모두부계측방사선 사진상 골두께와 3D model에서 상관관계를 보이는 부위에 대하여 회귀분석을 시행하였다. 이상의 횡적인 부위별 회귀분석을 통해 미니 임플랜트 식립 시 안전한 스크류의 길이를 결정하기 위한 골두께 예측에 도움이 될 것이다.

조선 후기 회화작품에 나타난 취병(翠屛)의 특성 (A Study on the Characteristics of Chuibyong(翠屛: a Sort of Trellis) in Paintings of Late Joseon Dynasty)

  • 정우진;심우경
    • 한국전통조경학회지
    • /
    • 제31권4호
    • /
    • pp.1-21
    • /
    • 2013
  • 본 연구는 회화자료의 분석을 통해 조선시대 취병의 특성과 제요소를 고찰한 것으로서 다음과 같은 결과를 도출하였다. 첫째, 조선시대 회화자료 25종에 대한 분석 결과, 취병은 주로 사생활 보호를 위한 차폐시설과 부지의 공간을 분할하는 구획시설로 기능하였으나, 내적으로는 정원에 품격과 아취를 부여하는 소품으로 설치되었다. 특히 취병 주변으로 학, 사슴등의 동물상 및 소나무, 파초, 대나무, 오동나무 등의 식물상과 괴석, 연못, 정자 등의 다양한 정원요소들이 나타났는데, 이것들은 이상적인 문인정원에 구비되어야 하는 일련의 조합으로 파악되었다. 둘째, 취병은 중국 고사(古事) 속 문인문화를 표상하는 관념적인 물상으로 인식되었다. 그러한 이미지는 고스란히 정원문화 속에 투영되었는데, '인물고사도 속 원림'을 모방 재현하는데 있어 취병은 중요한 경물로 사용되어 왔다. 셋째, 형태 기능 측면에서, 조선시대 회화 속에 나타난 취병들은 기본적으로 차폐 및 구획의 기능이 주요하였다. 사람 키를 웃도는 담장이나, 심지어 중국 대문 앞뒤에 설치되는 영벽의 높이까지 솟아 있기도 하여 공간적 필요에 따라 다양한 형태의 취병이 설치되었음을 알 수 있다. 넷째, 취병은 특정한 기능이나 입지상황 때문에 설치된 것보다는 당시 국내에 유행한 명대 문인문화의 유행과 밀접한 관련이 있다. 특히 중국에서 전해진 서원아집도 등에 나타난 취병의 도상은 한양을 중심으로 부유층의 저택에서 재현되었는데, 취병을 통해 부귀와 문인의 기상을 표현하려 했던 초기양식이 궁궐 및 상류층의 주택에서나 조성될 수 있는 고급 정원요소로 전화되었다. 또한 19세기 중엽 이후 취병의 활용은 평민의 주거양식으로 확산되는 이른바 저변화의 양상을 보였으며, 이는 취병이 토착화된 전개로 간주된다.

이냐시오 '영신수련'에 대한 분석심리학적 고찰 (A Jungian Perspective on 'Spiritual Exercises' of St. Ignatius)

  • 金正澤
    • 심성연구
    • /
    • 제25권1호
    • /
    • pp.27-64
    • /
    • 2010
  • 크리스챤 영성의 관점에서는 '영성(靈性)'이란 바로 우리가 우리 자신이 되게 하는 영적 씨앗으로써 누구나 그 씨앗을 발아시켜 자기 자신의 온전한 본 모습을 찾아가는 길이다. 자기실현(自己實現) 또는 개성화과정은 융의 중심사상으로, 개인적 성격의 발달을 지향하는 분화의 과정이다. 달리 말해 의식과 무의식의 통합을 이루어 자신이 가지고 있는 모든 기능을 온전히 제대로 사용할 수 있도록 함으로써 전체성(全體性)을 달성해 나가는 과정이다. 그렇다면 이는 인간 누구에게나 주어진 삶의 중심과제일 수밖에 없다. 이런 측면에서 보면, 영성신학적인 견해와 분석심리학적인 견해가 서로 만날 수 있는 길이 보인다. 스위스 취리히(Zurich)의 연방기술연구소에서 1938년부터 1941년까지 열렸던 특강 시리즈에서, 융은 동양과 서양의 전형적인 상징과 변환과정에 대한 고찰을 통해 요가와 이냐시오 성인의 '영신수련', 그리고 연금술에 대해 강의하면서, 서양을 대표하는 인간 정신의 변환의 도구로써 이냐시오의 '영신수련'을 들고 있다. 따라서 본 논문에서는 이냐시오의 '영신수련'에 대한 융의 견해를 중심으로 '영신수련'을 개성화의 과정과 비교해봄으로써 그 분석심리학적 함의를 조명해보는데 중점을 두었다.