• Title/Summary/Keyword: Transfer coefficient

Search Result 2,404, Processing Time 0.03 seconds

Materialistic Characterization of Waste Egg Shell and Fundamental Studies for Its Application to Wastewater Treatment (폐달걀껍질의 활용을 위한 물성조사 및 폐수처리 응용에의 기초연구)

  • Kuh, Sung-Eun;Kim, Dong-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.733-742
    • /
    • 2000
  • Fundamental materialistic characterization and adsorption/neutralization behavior of waste egg shell for heavy metal ion have been studied for its application to wastewater treatment. To investigate the structural change and thermal decomposition characteristics of egg shell. X-ray diffraction and FT-IR analysis were conducted for egg shell treated at $105^{\circ}C$ and $700^{\circ}C$, respectively. For the result of FT-IR analysis, the sample treated at $700^{\circ}C$ showed a reduced C-O absorption band compared with that of egg shell treated at $105^{\circ}C$, which may be due to the $CO_2$ release. Unlike to the result of FT-IR analysis, the XRD patterns of egg shell were almost similar for the cases of $105^{\circ}C$ and $700^{\circ}C$ treatment. however, characteristic diffraction pattern of CaO was observed for $850^{\circ}C$ treatment, at which $CaCO_3$ is known to be completely converted to CaO. TGA/DTA analysis showed a slow decline in weight loss up to $600^{\circ}C$ and, for $600{\sim}800^{\circ}C$ range, the weight loss became drastic by reason of $CO_2$ discharge, which was accompanied by an appearance of major endothermic peak. The ratio of practical breakthrough time to ideal one, total transfer unit, and mass transfer coefficient were observed to be increased as the adsorption was progressed in a multiple-column fixed-bed reactor using egg shell as an adsorbent, which signified the distribution effect of mass transfer for continuous adsorption reaction. The neutralization effect of egg shell for several types of acidic wastewater made of different mineral acids was not much different from each other except for the case of $H_2SO_4$, for which the neutralization reaction was thought to be retarded by the formation of gypsum.

  • PDF

Phenotypic Correlation between Carcass Traits and Serum Profiles taken Before and After Slaughter of Hanwoo Bulls and Steers (가축에서 시기별 혈액 성분과 도체 형질에 대한 표현형 상관에 관한 연구)

  • Jeon G. J.;Choy Y. H.;Cho K. H.;Kim M. J.;Kim H. C.;Choi J. G.;Lee C. W.;Hwang J. M.;Kim J. B.
    • Journal of Embryo Transfer
    • /
    • v.20 no.3
    • /
    • pp.239-253
    • /
    • 2005
  • Serum concentrations of Hanwoo steers and bulls as possible indicators of beef quality were analyzed to estimate their correlations with carcass traits. Blood samples were taken 2 months and right before shipping to abattoir and at the time of slaughter. And phenotypic correlation coefficients between serum concentrations and carcass traits were estimated. Beef yield index of steers was positively correlated with serum concentrations of total Protein (0.23), albumin (0.26), and calcium (0.31). But it was negatively co..elated with BUN (-0.30). Loin eye area was positively correlated with BUN (0.17) or with globulin (0.16). Back fat thickness was positively correlated with BUN (0.42) and inorganic phosphorus (0.20) being negatively correlated with total protein (-0.23), albumin (-0.33) and calcium (-0.33). Marbling score in the scale of 1 (scarcely marbled) through 9 (extremely marbled) was positively correlated with BUN (0.28) and negatively with IGF-I and calcium concentrations. Phenotype correlation coefficient of loin eye area with total protein concentration in the serum taken from steers right before shipment was estimated to be -0.16 and that with BUN was estimated to be -0.15. Serum concentrations of IGF, glucose, creatinine and on organic phosphorus from steers measured right before shipment were negatively correlated with respective correlation coefficient estimates as -0.21, -0.21, -0.19 and -0.18. Marbling score was negatively co..elated with serum creatinine (-0.16) measured at that time. Beef yield index of steers was positively correlated (0.31) with age adjusted calcium concentration in the serum taken at the time of slaughter. Correlation between body weight and BUN at slaughter was 0.17 At slaughter, loin eye area was negatively correlated with albumin (-0.19) and back fat thickness was also negatively correlated with age adjusted calcium concentration (-0.38). Marbling was negatively correlated with age adjusted calcium concentration(-0.17). Serum concentrations of testosterone, calcium and inorganic phosphorus taken in 2 months before slaughter were negatively but highly correlated with yield index(0.71, 0.67 and -0.71), respectively. Body weight at slaughter was positively was negatively correlated (0.67) with calcium level while dressing percentage was negatively (-0.69) correlated with serum glucose concentration, 2 months prior to slaughter. Correlation coefficients between back fat thickness and cortisol, between back fat thickness and inorganic phosphate were both positive (0.29 and 0.69). Marbling score was negatively correlated with creatinine (-0.81) and positively with BUN (0.87). Body weight loss during shipping was positively correlated with albumin and inorganic phosphate (0.77, 0.83). Yield index of bulls was positively correlated with serum testosterone concentration (0.66). Dressing percentage was positively and highly correlated with globulin (0.73). Back fat thickness of bulls, however, was negatively correlated with testosterone (-0.60). Loin eye area of bull carcasses was positively correlated with testosterone (0.40). Mar-blaine was negatively co..elated with creatinine (-0.55). Yield index of bulls and age adjusted HDLC concentration at slaughter was negatively correlated (-0.71). Dressing percentage of bulls was positively and highly correlated with globulin concentration (0.70). Back fat thickness was also positively correlated with HDLC (0.69) in the serum taken at slaughter. Correlation coefficients between carcass weight and triglyceride, between loin eye are and testosterone and between marbling score and creatinine or glucose were 0.51, -0.91 and -0.58, respectively.

Hepatitis A Virus Antibodies in Korean Mothers and Their Neonates (산모와 신생아의 A형 간염 항체가에 관한 연구)

  • Kim, Kyung Burm;Shin, Young Kyoo;Lee, Kee Hyoung;Eun, Baik Lin;Lim, Chae Seung
    • Pediatric Infection and Vaccine
    • /
    • v.6 no.2
    • /
    • pp.234-238
    • /
    • 1999
  • Purpose : This study was performed to evaluate the seropositivities and levels of Hepatitis A Virus(Hav) antibody in term pregnant women and their neonates, and the transplacental transfer rate of maternal Hav-specific IgG(Hav IgG) from tenn pregnant women to their neonates. Methods : During Jan. 1st, 1998 to May. 31 tho 1998, we collected the 42 pairs of sera from pregnant women and umbilical cord of their neonates in Korea University Ansan Hospital. The serum levels of Hav IgG were measured by the RIA method. Results : 1) The seropositivities of Hav IgG were 78.6% in mothers and 81.0% in neonates. There was no statistical difference of mean antibody(Ab) levels between mothers and neonates. There was significant correlation of Ab levels between maternal sera and neonatal umbilical cord sera(correlation coefficient r=0.9285, P<0.001). 2) There were no significant correlations between neonatal Hav IgG level and other factors such as maternal age, gestational age and initial body weight of neonates. Conclusion : Seropositivities of Hav IgG tenn-pregnant women was comparable to those of their neonates. Pregnant women and their neonates can be protected from Hav infection.

  • PDF

Effects of Core Competence and Resource Sharing on the Relational Bond among Franchisees and on Re-contract Intention in the Franchising Parent Companies (프랜차이즈 모기업 핵심역량 자원이 가맹점 관계결속과 재계약의도에 미치는 영향)

  • Huh, Yeong-Uk;Ju, Mal-Chan
    • Journal of Distribution Science
    • /
    • v.12 no.4
    • /
    • pp.11-22
    • /
    • 2014
  • Purpose - The domestic franchise industry has made significant contributions to industry such as investment, employment, and community economy development, facilitating growth potential. The franchise industry provides management knowhow transfer between parent companies and franchisees as per contracts addressing use of business signs, franchisees' independent position, franchisor support, and royalties to be paid to the franchisors. However, many franchisors lack management knowhow and provide insufficient support because of poor control of franchisees and not having a systematic approach to support. This results in dissatisfied franchisees and failure to establish long-term relationships. Few studies have examined relational commitment and/or re-contract intention by support resources between franchisors and franchisees, despite a considerable output of theories and studies of the growth of the franchise industry. The purpose of this study, therefore, was to examine the effects of the ability to provide resources on relational commitments and re-contract intention, and to suggest causal relationships and implications. Research design, data, and methodology - The subject was domestic franchisors registered with the Association of Franchise with more than 50 franchisees. Franchisees under contract for 2 years and considering re-contract of their franchise 2 years later were used. The subjects totaled 300 franchisees in Seoul. A questionnaire survey was used to investigate the subject of franchisees' concessions during the 10 days from November 21, 2013 to November 30, 2013. After excluding 16 surveys with poor answers, 284 responses were finally used. Four areas and 44 questions were used. A nominal scale was used for four common characteristics questions including gender, ages, educational background, and franchise managing time. Questions regarding ability, relational commitment, and re-contract intention made use of a Likert 5-point scale. Data coding and data cleaning were used. SPSS 18.0 was used as follows. First, frequency analysis was done to investigate demographic characteristics. Second, exploratory factor analysis was done to verify validity of testing tools, and Cronbach's α coefficient was used to verify reliability. Third, correlation analysis and multiple regression analysis were done. An exploratory factor analysis was done to verify validity of concepts. A correlation analysis was done to test relationships between the variables, and multiple regression analysis was done to verify franchisor's ability, franchisees' relational commitment, and re-contract intention. Results - The following were the outcomes. First, store operation management, finance operation management, and human resource management affected the calculated bond. Second, store operation management and finance operation management affected the emotional bond. Third, store operation management, finance operation management, human resource management, and marketing management affected the prescriptive bond. Fourth, calculated bond and prescriptive bond had an effect on re-contract intention. Conclusions - As stated above, in franchise management, parent companies' offer and instruction of core competence to their franchisees as an information resource could improve the relational bond by helping them grow together through the resource sharing. Consequently, core competence factors were promoting factors that could improve franchisees' re-contract intention for a long time.

Experimental Study for Estimation of Air Heating Performance and Improvement of Thermal Performance of Hybrid Solar Air-water Heater (태양열 공기-물 가열기의 공기 가열 성능 평가 및 열적 성능 개선을 위한 실험적 연구)

  • Choi, Hwi-Ung;Kim, Young-Bok;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.1
    • /
    • pp.47-57
    • /
    • 2017
  • Solar energy is one of the important renewable energy resources. It can be used for air heating, hot water supply, heat source of desiccant cooling system and so on. And many researches for enhancing efficiency have been conducted because of these various uses of solar thermal energy. This study was performed to investigate the air heating performance of hybrid solar air-water heater that can heat air and liquid respectively or simultaneously and finding method for improving thermal performance of this collector. This collector has both liquid pipe and air channel different with the traditional solar water and air heater. Fins were installed in the air channel for enhancing the air heating performance of collector. Also air inlet & outlet temperature, ambient temperature and solar collector's inner part temperature were confirmed with different air velocity on similar solar irradiance. As a result, temperature of heated air was shown about $43^{\circ}C$ to $60^{\circ}C$ on the $30^{\circ}C$ of ambient temperature and thermal efficiency of solar collector was shown 28% to 73% with respect to air velocity. Also, possibility of improvement of thermal performance of this collector could be ascertained from the heat transfer coefficient calculated from this experiment. Thus, it is considered that the research for finding optimal structure of hybrid solar air-water heater for enhancing thermal performance might be needed to conduct as further study based on the method for improving air heating performance confirmed in this study.

Thin Film Chromel-Alumel Multjunction Thermal Converter (박막형 크로멜-알루멜 다중접합 열전변환기)

  • Jung, In-Sik;Kim, Jin-Sup;Lee, Jung-Hee;Lee, Jong-Hyun;Shin, Jang-Kyoo;Park, Se-Il;Kwon, Sung-Won
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.37-45
    • /
    • 1999
  • For the purpose of reducing the output voltage fluctuation of thin film multijunction thermal converter, EVANOHM alloy-S and chromel-alumel thermocouple were used as a thin film heater material and as a thermoelement of thrmopile, respectively. The temperature coefficient of the resistance of thin film EVANOHM alloy-S heater was about $1.4 {\times} 10^4/^{\circ}C$, which is very small compared to other materials, and thin film chromel-alumel thermocouple showed relatively small difference of the Seebeck coefficients about $38 {\mu}V/K$. The output voltage fluctuation of the thermal converter was about 0.06% for the initial 120 seconds in air and decreased considerably after preheating for 5 minutes or more. The respective AC-DC voltage and current transfer error ranges of the thermal converter were about ${\pm}$1.6 ppm and ${\pm}$0.7 ppm in the frequency range from 10Hz to 10 kHz and increased remarkably below 10 Hz or above 10 kHz.

  • PDF

Changes of Sound Absorption Capability of Wood by Organosolv Pretreatment (유기용매 전처리에 의한 목재의 흡음성능 변화)

  • Kang, Chun-Won;Choi, In-Gyu;Gwak, Ki-Seob;Yeo, Hwan-Myeong;Lee, Nam-Ho;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.4
    • /
    • pp.237-243
    • /
    • 2012
  • Sound absorption capability and anatomical features of the organosolv pretreated Japanese larch and yellow poplar wood were estimated by stereoscopic observation and two microphone transfer function method. Sound absorption capabilities of organosolv treated wood, in the entire estimated frequency range (50~6,400 Hz), were higher than those of control specimen. Especially, the treated wood's absorption capabilities measured in the frequency range of 2~4 kHz were about two times higher than those of control specimen. By the organosolv pretreatment (at $70{\sim}120^{\circ}C$), the weight loss of wood occurred in less than 1% of total weight of wood and the porosity of wood increased slightly. In addition, it was presupposed that microstructural changes of wood occurred during organosolv pretreatment and this structural changes cause the increasing of the sound absorption capability of wood.

Analysis on Heat Transfer Coefficient of The Fluidized - Bed Combustion for Management of Sludge (슬러지 처리를 위한 유동층 연소로의 열전달률 해석)

  • Kim, Seong-Jung;Lee, Je-Hak
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.27-33
    • /
    • 2012
  • According to the statistics of the Ministry of Environment, the emission of sewage sludge is increased by 7~9% yearly. In the future, it will be increased continuously because of extension of sewage disposal plants, high class treatment for removing nitrogen and phosphorus. Until now, we have depended on reclamation for lots of quantity and some part has been treated by ocean emission. But, direct reclamation of organic waste will be prohibited and even ocean emission will be prohibited now, so the treatment of sludge is put on emergency alert. Bio-gas can be produced by applying anaerobic digestion method for the recycling or refuse derived fuel can be conducted by applying carbonization method. However, the process is difficult, causes bad smell and makes it the second waste, so it cannot be practical method in fact. This study applied a fluidized bed combustor for sewage sludge treatment technologies that can actually take advantage of key technologies in order to verify its purpose is to demonstrate selected. If applying the fluidized bed combustor, it can be easily utilized as the replaced resource of energy(fuel) in the countries whose energy resources are insufficient, like our country. Especially, if applying only original strengths of the fluidized bed combustor sufficiently, the sewage sludge can be treated simply, eco-friendly, sanitarily and economically. Particularly, it is verified as the energy technology suitable for government's green growth policy.

A study on the thermal performance of all glass evacuated tube collector and refrigerator using solar energy (태양열을 이용한 이중진공관형 집열기와 냉동기의 열성능에 관한 연구)

  • Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.324-331
    • /
    • 2013
  • All evacuated tube collector is being constantly studied since it can reduce the conductive heat loss in absorber by using vacuum technology and has advantage of heat transport capacity and quick thermal response in comparatively small temperature difference. This study investigated the dynamic thermal performance of the solar collector with the control condition of solar irradiance and fluid temperature by using performance experimental apparatus which is combined with solar collector and refrigerator, examined the thermal characteristics in definite temperature range of fluid in constant temperature tank by simultaneously measuring refrigerating performance. As a result of it, I deducted the related equation of collector efficiency and found that mean collector efficiency has increased through quick heat transfer characteristics according to increase of outdoor temperature and irradiance in case of outlet temperature of constant temperature tank $22^{\circ}C$ when set outlet temperature of solar collector $25^{\circ}C$ with outlet temperature of constant temperature tank $18^{\circ}C$ & $22^{\circ}C$. Also COP of refrigerator was acquired value of 6.2~7.1 at outlet temperature of constant temperature tank $18^{\circ}C$.

Experimental Study of Characteristics of Three-Ring Impedance Meter and Dependence of Characteristics on Electric Conductivity of Fluids (3-ring 임피던스미터의 유체 전기 전도도 독립성에 대한 실험적 연구)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1027-1033
    • /
    • 2010
  • A two-phase (gas-liquid) flow is a common phenomenon in fluidic systems, e.g., fluidic systems in the electro-magnetic or nuclear power generation industry and in the steel industry. The measurement of a two-phase flow is important for guaranteeing the safety of the system and for achieving the desired performance. The measurement of the void fraction, which is one of the parameters of the two-phase flow that determines the pressure drop and heat transfer coefficient, is very important. The time resolution achieved by employing the impedance method that can be used to calculate the void fraction from the impedance of the fluid is high because the electric characteristics are taken into account. Therefore, this method can be employed to accurately measure the void fraction without distortion of flow in real time by placing electrodes on the walls of the tubes. Coney analytically studied a ring-type impedance meter, which can be employed in a circular tube. The aim of this study is to experimentally verify the robustness of a three-ring impedance meter to variations in the electric conductivity of the fluid; this robustness was suggested by Coney but was not experimentally verified.