1 |
Test methods for solar collectors, KS B ISO 9806-3, 2003 (in Korean).
|
2 |
R. Schmid, R. E. Collins, and B. A. Pailtrope, "Heat transport in Dewar-type evacuated tubular collectors ", Journal of Solar Energy, vol. 45, pp. 291-300, 1990.
DOI
ScienceOn
|
3 |
S.-T. Hyun, Y.-H. Kang, H.-K. Yoon, C.-K. Yoo, and M.-C. Kang, "A study on the thermal performance of evacuated tube collectors for process heat applications", Proceeding of Korea Institute of Ecological Architecture and Environment, pp. 71-75, 2002 (in Korean).
|
4 |
J.-H. Hyun and W.-G. Chun, "A comparative analysis on the thermal performance of solar vacuum collector tubes", Journal of the Korean Solar Energy Society, vol. 23, no. 3, pp. 15-17, 2003 (in Korean).
과학기술학회마을
|
5 |
H.-Y. Kawk and U.-C. Shin, "Analysis of thermal performance of a solar heating & cooling system", Journal of the Korean Solar Energy Society, vol. 28, no. 4, pp. 43-49, 2008 (in Korean).
과학기술학회마을
|
6 |
E.-Y. Choi, Y. Kim, and T.-B. Seo, "Effects of absorber tube shape and operating conditions on thermal performance of all glass evacuated tube solar collectors", Journal of the Korean Solar Energy Society, vol. 25, no. 1, pp. 19-25, 2005 (in Korean).
과학기술학회마을
|
7 |
P.-H. Son, B.-W. Park, Y.-S. Lee, O.-J. Lee, S.-H. Choi, and S.-H. Yoon, "A study of collecting Efficiency of flat plate solar collector by collecting angle", Proceeding of the Korean Society of Marine Engineering, pp. 163-164, 2007 (in Korean).
|
8 |
W.-S. Kim and H.-H. Cho, "Experimental study on the operating characteristics of a solar hybrid heat pump system according to indoor setting temperature", Journal of the Korean Solar Energy Society, vol. 30, no. 6, pp. 50-58, 2010 (in Korean).
과학기술학회마을
|
9 |
W.-S. Kim and H.-H. Cho, "Study on the performance characteristics of the solar hybrid system with heat pump operating temperature during winter season", Korean Journal of Air-Conditioning and Refrigeration Engineering, vol. 22, no. 12, pp. 821-827, 2010 (in Korean).
과학기술학회마을
|
10 |
H.-J. Joo, J.-B. Kim, J.-B. Kim, and K.-H. Kwak, "Thermal performance study of various heat pipe working fluid for evacuated tubular solar collector", Journal of the Korean Solar Energy Society, vol. 27, no. 4, pp. 97-98, 2007 (in Korean).
과학기술학회마을
|
11 |
K.-B. Yim and C.-J. Kim, "A study on design and performance of a heat pipe for the application to solar collector", Journal of the Korea Society for Energy Engineering, vol. 2, no. 2, pp. 176-186, 1993 (in Korean).
과학기술학회마을
|
12 |
C.-J. Kim and J.-S. Lee, "A fundamental study on the heat transfer characteristics of a Dewar-type evacuated glass tube solar collector with a heat pipe located at the center", Journal of the Korean Solar Energy Society, vol. 16, no. 1, pp. 39-49, 1996 (in Korean).
|