• Title/Summary/Keyword: Toxic substances leakage

Search Result 16, Processing Time 0.023 seconds

A Study on the Simulation of Damage Distance for Toxic Substances Leakage (사고대비물질 누출 시 독성피해 영향범위 상관관계식 개발에 관한 연구)

  • Jo, Ga-Young;Lee, Ik-Mo;Hwang, Yong-Woo;Moon, Jin-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.599-607
    • /
    • 2017
  • Since 2015, small and medium domestic enterprises that treat more than a certain quantity of chemical substances in accordance with the Chemical Substance Control Act are obliged to submit an off-site impact assessment and risk management plan. In order to reduce the administrative and economic burden of the risk assessment, its impact was determined. Toxic leaks of nitric acid, methanol, and acetic acid were estimated and the correlations (between them?) were calculated. In addition, the correlations of this study were used to compare the KORA results according to the accident scenarios of the actual workplace and the extent of the damage as a function of distance in the case of toxic leaks. In this study, the correlation formula of the materials can be used to quickly determine the damage distance in the event of the accidental leakage of materials in the road or workplace, and to prepare emergency plans and respond to emergencies more quickly.

A Study on the Range of Damage Effects of Benzene Leakage Accidents using the KORA Program (KORA 프로그램을 활용한 벤젠 누출사고 피해영향범위에 관한 연구)

  • Cha, Jeong-Min
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.112-120
    • /
    • 2019
  • Benzene is a class 4 hazardous material according to the Act on the Safety Control of Hazardous Substances. This study qualitatively evaluated the damage size of a "toxic" accident and "pool fire" accidents based on benzene in a virtual scenario of a fire and leakage accident during unloading at a port facility. The KORA program was used as an evaluation method, which is supported as a universal program by the National Institute of Chemical Safety. The range of damage effects of a benzene-induced fire and leakage accident was predicted. In the case of toxic damage range, the accident's damage effect range for the "worst case scenario" was reduced by up to 5.11% with a decrease in the size of the leakage hole. In the case of the leakage time, the damage effect range increased to 145.12% with a 10 min leakage time compared to that of a 5 min leakage time and went up to 20 min (212.29%) with a 20 min leakage time. In the case of pool-fire-induced damage, the damage effect range by radiant heat in the "worst case scenario" was 228.8 m in radius from the center of the handling facility. In the "alternative scenario," the damage effect range by radiant heat was reduced by up to 8.26% compared to that in the "worst case scenario" since the size of the leakage hole was decreased by reducing the cross-sectional area of the pipe.

Analysis on the Legal Control Levels and GHS Classification Information Status for Strongly Acidic Hazardous Materials (강산성 유해화학물질의 법적관리 수준 및 GHS 분류정보 제공 실태분석 연구)

  • Lee, Kwon Seob;Jo, Ji Hoon;Park, Jin Woo;Song, Se Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.384-392
    • /
    • 2013
  • Objective: This study inspected incident cases, legal control levels, and GHS(Globally Harmonized System of Classification and Labeling of Chemicals) classification results of strong acids such as hydrogen fluoride, hydrogen chloride, nitric acid, and sulfuric acid, which have been responsible for many recent chemical accidents. As a result, it is deemed necessary for legal control levels of these strong acids to be revised and GHS classification be managed nation-wide. Methods: This study inspected incident cases and legal control levels for strong acids such as hydrogen fluoride, hydrogen chloride, nitric acid, and sulfuric acid. The study analyzed and compared chemical information status and GHS classification results. Results: There were 76 domestic incidents involving strongly acidic hazardous materials over the five years between 2007 and 2011. They include 37 leakage incidents(46.7%) within a workplace, 30 leakage incidents(39.5%) during transportation, and nine leakage incidents(13.8%) following an explosion. The strongly acidic materials in question are defined and controlled as toxic chemicals according to the classes of Substances Requiring Preparation for Accidents, Managed Hazardous Substance, Hazardous Chemical(corrosive) as set forth under the Enforcement Decree of the Toxic Chemicals Control Act and Rules on Occupational Safety and Health Standards of Occupational Safety and Health Act. Among them, nitric acid is solely controlled as a class 6 hazardous material, oxidizing liquid, under the Hazardous Chemicals Control Act. The classification results of the EU ECHA(European Chemicals Agency) CLP(Commission Regulation(EC) No. 790/2009 of 10 August 2009, for the purposes of its adaptation to technical and scientific progress, Regulation(EC) No 1272/2008 of the European Parliament and of the Council on classification, labeling and packaging of substances and mixtures) and NIER (National Institute of Environmental Research) are almost identical for the three chemicals, with the exception of sulfuric acid. Much of the classification information of NITE (National Institute of Technology and Evaluation) and KOSHA(Korea Occupational Safety and Health Agency, KOSHA) is the same. NIER provides 12(41.4%) out of 29 classifications, as does KOSHA.

A Study on Improving Management of Substances Requiring Preparation for Accidents Facilities (사고대비물질 취급시설 관리방안 연구)

  • Kim, S.B.;Park, C.H.;Cho, M.S.;Lee, J.S.;Kim, J.M.;Noh, H.R.;Seok, G.S.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.77-82
    • /
    • 2012
  • The leakage of toxic chemicals impact seriously on human being and environment, therefore during their treatment process, a proper management system is necessary to control their toxic effect. This study was designed to suggest the management regulation that supports business managers and facilities management. There are no extra regulation to control emergency accidents and terrors in chemical facilities. Developed countries like USA operate the management standards to control the toxic chemical and facilities according to their toxicity and processes. In order to solve this problem, we have analysed the advanced nations standard methods of security in chemical plants to study the new security management regulation which helps to prevent the chemical accidents. Especially, in USA, CCPS (Center for Chemical Process Safety), SVA (Security Vulnerability Assessment) and RBPSs (Risk-Based Performance Standards) of DHS (Department of Homeland Security) were invest I gated. On the basis of the results, we have suggested the application methods of the security and safety regulation in Korea.

Toxic Concentration(T-LOC) Endpoint Distance Study for Fire Brigade Protection in Response to Chemical Accidents (화학사고 초기대응 소방대 보호를 위한 독성농도(T-LOC) 끝점거리 연구)

  • Jong Chan Yun;Chul Hee Cho;Jeong Hun Won
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.60-71
    • /
    • 2023
  • The purpose of this study is to propose a quantitative toxicity endpoint distance suitable for the initial response of firefighters by comparing and analyzing the commonly applied toxic level of concern (T-LOC), specifically emergency response planning guidelines (ERPG), acute exposure guideline levels (AEGL), and immediately dangerous to life or health (IDLH). This is to protect the fire brigade, which responds to toxic chemical accidents first during the golden time. Using areal locations of hazardous atmospheres, a damage prediction program, the amount of leakage for both acidic and basic substances, along with the endpoint distance, were analyzed for alternative accident and worst-case accident scenarios. The results showed that the toxicity endpoint distance, serving as a compromise between Level-3 and Level-2 of T-LOC, was longer than ERPG-3 and shorter than ERPG-2 with IDLH, while its values were analyzed in the order of ERPG-2, AEGL-2, IDLH, AEGL-3, and ERPG-3. It is suggested that the application of IDLH in an emergency (red card) and ERPG-2 endpoint distance in a non-emergency (non-red card) can be utilized for the initial response of the fire brigade.

A Numerical Study of Building Orientation Effects on Evacuation Standard in Case of Toxic Gas Leakage (독성 가스 누출 시 건물 방향이 대피 기준에 미치는 영향에 관한 수치 해석 연구)

  • Seungbum Jo
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.12-18
    • /
    • 2023
  • The effective evacuation strategy according to the accident scenario is crucial to minimize human casualties in the event of toxic gas leak accidents. In this study, the effect of the direction of a building and the location of an industrial complex on the increase in indoor concentration and outdoor diffusion was examined under the same leakage conditions, and effective evacuation criteria were established. In addition, the guidelines for building directions were suggested when constructing buildings that would mitigate human damage caused by chemical accidents. Three scenarios where buildings faced the front, side, and rear of the leakage direction were investigated through CFD simulations. The results revealed that when the building faced the industrial complex, both indoor and outdoor average gas concentrations increased significantly, reaching up to 120 times higher than the other two orientations. Moreover, the indoor space was filled with toxic gas substances more than twice in the same time due to the rapid increase of indoor concentration rate. In cases where the building's windows were positioned at the front, toxic gas stagnation occurred around the building due to pressure differences and reduced flow velocities. Based on our findings, the implementation of these guidelines will contribute to safeguarding residents by minimizing exposure to toxic gas during chemical accidents.

Characteristic Analysis of Casualty Accidents in Chemical Accidents (화학사고에 의한 인명사고 특성 분석에 관한 연구)

  • Lee, Tae-Hyung;Lee, Deok-Jae;Shin, Chang-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.81-88
    • /
    • 2017
  • This study analyzed chemical accidents each year according to the status, type of accident, accident place, business size, and chemical substance. The results of the chemical accident investigation were 16 cases in 2013, 27 cases in 2014, 46 cases in 2015, and 23 cases in 2016. According to the type of chemical accident, number of accidents, and casualty accidents, leakage was found to be the major cause. As a result of accidents and casualties caused by chemical accidents, workplaces had the highest numbers in all survey items. An examination of the top 10 accident materials revealed 9 substances to be hazardous chemicals. These materials were accident preparedness substances, and toxic substances.

A Study on Total Hazard Level Algorithm Development for Hazardous Chemical Substances (유해화학물질의 종합위해등급 알고리즘 개발에 관한 연구)

  • 고재선;김광일;정상태
    • Fire Science and Engineering
    • /
    • v.14 no.4
    • /
    • pp.7-16
    • /
    • 2000
  • In the study, three criteria(toxicity, fire & explosion, environment) and damage prediction method for each case was set up, and all these criteria were applied to the subject substance that was selected as hazardous level by integrating all criteria through Algorithm. Particularly, the environment criterion is a comprehensive concept, environment index modeling by combining USCG(United State Coast Guard) & MSDS(Material Safety Data Sheet) environment criteria classifications and the environment part of MFPA's health hazardousnes(Nh). And for damage prediction method of each criterion were adopted and they were applied to hazardous chemical substances in use or stored by chemical substance related enterprises located in each region that made possible to set up total hazard level of used substances(inflammability, poisonousness and counteraction on a unit substance, and hazard level & display modeling on environment) & damage prediction in case of accident & solidity setup(CPQRA: Chemical Process Quantitative Risk Assessment, IAEA: International Atomic Energy Agency, VZ eq: Vulnerable Zone) risk counter. Thus it is deemed that it can be applied to toxic substance leakage that can happen during any chemical processing & storage, application as a tool for prior safety evaluation through potential dangerousness computation of fire & explosion.

  • PDF

A Study on Measures to Prevent Leakage of Process Fluid from the VCR Fitting used in the Semiconductor Manufacturing Process (반도체 제조 공정에서 사용되는 이송배관 연결부위(VCR Fitting)로부터 공정유체 누출사고 예방 대책에 관한 연구)

  • Dae Joon Lee;Sang Ryung Kim;Sang Gil Kim;Chung Sang Kang;Joon Won Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.79-85
    • /
    • 2023
  • Recently, in the semiconductor process, large companies are seeking process changes from memory semiconductors to the foundry due to the increase in demand due to the 4th industry. industry is expanding. The characteristics of special gases and precursors, which are raw materials used to produce these semiconductor chips, are toxic, pyrophoric, inflammable, and corrosive. These semiconductor raw materials are operated in a closed system and do not leak to the outside during normal times, but when leaked, they spread to the inside of the gas box, and when proper ventilation is not provided inside the gas box, they spread to the outside, causing fires, explosions, or toxic substances. It can lead to major accidents such as leakage. Recently, there have been cases of accidents in which hazardous materials leaked from the closed system of the semi conductor process and spread to the inside and outside of the gas box. . In this study, we propose preventive measures based on the case of an accident in which raw material leaked from the VCR fitting, which is the connection part of the semiconductor raw material transfer pipe, and spread to the outside of the gas box.

Examination on Autonomous Recovery Algorithm of Piping System (배관 체계 자율 복구 알고리즘 비교, 분석 및 고찰)

  • Yang, Dae Won;Lee, Jeung-hoon;Shin, Yun-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.1-11
    • /
    • 2021
  • Piping systems comprising pumps and valves are essential in the power plant, oil, and defense industry. Their purpose includes a stable supply of the working fluid or ensuring the target system's safe operation. However, piping system accidents due to leakage of toxic substances, explosions, and natural disasters are prevalent In addition, with the limited maintenance personnel, it becomes difficult to detect, isolate, and reconfigure the damage of the piping system and recover the unaffected area. An autonomous recovery piping system can play a vital role under such circumstances. The autonomous recovery algorithms for the piping system can be divided into low-pressure control algorithms, hydraulic resistance control algorithms, and flow inventory control algorithms. All three methods include autonomous opening/closing logic to isolate damaged areas and recovery the unaffected area of piping systems. However, because each algorithm has its strength and weakness, appropriate application considering the overall design, vital components, and operating conditions is crucial. In this regard, preliminary research on algorithm's working principle, its design procedures, and expected damage scenarios should be accomplished. This study examines the characteristics of algorithms, the design procedure, and working logic. Advantages and disadvantages are also analyzed through simulation results for a simplified piping system.