Browse > Article
http://dx.doi.org/10.14346/JKOSOS.2021.36.4.1

Examination on Autonomous Recovery Algorithm of Piping System  

Yang, Dae Won (Department of Safety Engineering, Chungbuk National University)
Lee, Jeung-hoon (Department of Mechanical Engineering, Changwon National University)
Shin, Yun-Ho (Department of Safety Engineering, Chungbuk National University)
Publication Information
Journal of the Korean Society of Safety / v.36, no.4, 2021 , pp. 1-11 More about this Journal
Abstract
Piping systems comprising pumps and valves are essential in the power plant, oil, and defense industry. Their purpose includes a stable supply of the working fluid or ensuring the target system's safe operation. However, piping system accidents due to leakage of toxic substances, explosions, and natural disasters are prevalent In addition, with the limited maintenance personnel, it becomes difficult to detect, isolate, and reconfigure the damage of the piping system and recover the unaffected area. An autonomous recovery piping system can play a vital role under such circumstances. The autonomous recovery algorithms for the piping system can be divided into low-pressure control algorithms, hydraulic resistance control algorithms, and flow inventory control algorithms. All three methods include autonomous opening/closing logic to isolate damaged areas and recovery the unaffected area of piping systems. However, because each algorithm has its strength and weakness, appropriate application considering the overall design, vital components, and operating conditions is crucial. In this regard, preliminary research on algorithm's working principle, its design procedures, and expected damage scenarios should be accomplished. This study examines the characteristics of algorithms, the design procedure, and working logic. Advantages and disadvantages are also analyzed through simulation results for a simplified piping system.
Keywords
autonomous piping system; autonomous recovery algorithm; rupture detection and isolation; damage control;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 R. A. Silva, C. M. Buiatti, S. L. Cruz and J. A. F. R. Pereira, "Pressure Wave Behaviour And Leak Detection In Pipelines", Computers&Chemical Engineering, Vol. 20, Supplement 1, pp. S491-496, 1996.   DOI
2 L. Boaz, S. Kaijage and R. Sinde, "An Overview of Pipeline Leak Detection and Location Systems", Proceedings of the 2nd Pan African International Conference on Science, Computing and Telecommunications, pp. 133-137, 2014.
3 M. Shinozuka, P. H. Chou, S. H. Kim, H. R. Kim and L. Fei, "Non-invasive Acceleration-based Methodology for Damage Detection and Assessment of Water Distribution System", Smart Structures and Systems, Vol. 6, No. 5, pp. 545-550, 2010.   DOI
4 H. O. Song and C. J. Lee, "A study on the Temporary Storage Facility for Mitiagting the Leakage Accident", J. Korean Soc. Saf., Vol. 35, pp. 1-5, 2020.
5 H. Y. Kim and S. H. Jung, "Investigation on Damage Effect Distance for High Pressure underground Flammable Gas Pipelines", J. Korean Soc. Saf., Vol. 33, pp. 33-38, 2018.   DOI
6 R. Jafari, S. Razvarz and A. Gegov, "Deep Learning for Pipeline Damage Detection : an Overview of the Concepts and a Survey of the State-of-the-Art", 2020 IEEE 10th International Conference on Intelligent Systems (IS), pp. 178-182, 2020.
7 NRL-USN, "DC-ARM Organizational Procedures and Manning for Smart Controller", 2001.
8 R. H. Jeoung and B. K. Lee, "Fault Detection Signal for Mechanical Seal of Centrifugal Pump", J. Korean Soc. Saf., Vol. 27, pp. 20-27, 2012.
9 C. S. Shin, Y. J. An and G. S. Byun, "A Study on the Improvement of Water-Leakage Detection Reliability in Local Heating System", J. Korean Soc. Saf., Vol. 14, pp. 66-72, 1999.
10 NRL-USN, "Development of DC-ARM Reflexive Smart Valve", 2001.
11 A A Belsky et al., "Electrotechnical Complex for Autonomous Power Supply of Oil Leakage Detection Systems and Stop Valves Drive Control Systems for Pipelines in Arctic Region", J. Phys.: Conf. Ser., 1753 012062, 2020.   DOI
12 NRL-USN, "Evaluation of Reflexive Valve Logic for a Shipboard Firemain", 2000.
13 NRL-USN, "Evaluation of Firemain Architectures and Supporting Reflexive Technology", 1999.
14 Y. H. Shin, B. C. Jung, S. H. Lee and S. J. Moon, "Development of Damage Management Technology on Rupture of Piping System by Smart Valve", Korean Society for Noise and Vibration Engineering, Vol. 10, pp. 319, 2018.
15 C. Sandberg, J. Holmes, K. Mccoy and Heinrich Koppitsch, "The Application of a Continuous Leak Detection System to Pipelines and Associated Equipment", in IEEE Transactions on Industry Applications, Vol. 25, No. 5, pp. 906-909, 1989.   DOI
16 NRL-USN, "Damage Control Automation for Reduced Manning (DC-ARM) Supervisory Control System Software Summary Final Report", 2002.
17 NRL-USN, "The Evaluation of the Autonomic Fire Suppression System Concept of Operations and PDA Cooling Effectiveness", 2003.
18 S. Rahman, N. Ghadiali, D. Paul and G. Wilkowski, "Probabilistic Pipe Fracture Evaluations for Leak-Rate-Detection Applications", US-Nuclear Regulatory Commission, 1995.