• Title/Summary/Keyword: Total leakage current

Search Result 98, Processing Time 0.024 seconds

Leakage Current Characteristics of 18kv ZnO Lightning Arresters by Accelerated Aging Test (가속열화시험에 의한 18kV ZnO 피뢰기의 누설 전류 특성 분석)

  • Kim, Ju-Yong;Song, Il-Geun;Kim, Chan-Yeong;Mun, Jae-Deok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.62-67
    • /
    • 2002
  • This paper provides the results of accelerated aging test of 18kV ZnO lightning arresters to investigate the leakage current characteristics. It was impossible to establish the replacement criterion for field operating lightning arrester because conventional aging test was only focused on the aging of ZnO elements. In general, it is possible to replace the aged arresters before the failure in the field using the leakage current measurement because it must be increased by the aging. But we can not use the method because we don't know the characteristics of the installed lightning arresters. Therefore in this paper we applied operating voltage and accelerating cycle which consists of temperature and humidity to the arresters. Then we measured the variation of total and resistive leakage current and found out the characteristics of the acted lightning arresters.

Analysis of Leakage Current Diagnosis According to Online and Offline Conditions (On-Line 및 Off-Line 상태에 따른 누설 전류 진단 분석)

  • Han, Kyung-Chul;Lee, Gyeong-Seop;Choi, Yong-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.4
    • /
    • pp.261-266
    • /
    • 2018
  • When the clamp meter approaches the electric path where current is flowing, leakage current can be measured at a distance from the electric current because the induced current increases as the magnitude of the current increases and approaches nearer to the electric path. Therefore, measurements were carried out from a distance to avoid this effect. In addition, the measured values differ depending on the location of the power line that penetrates the ZCT of the clamp meter, thus measurements were performed at a location where this effect was minimized. The fraction of compliant branch circuits, whose leakage current was lower than 1.00 mA, was found to be 69.0% out of the total of 439 branch circuits, while the percentage of compliant branch circuits having an insulation resistance higher than $0.20M{\Omega}$ was found to be 93.2%. The reason why the percentage of compliant branch circuits with low leakage current was low might be due to the inclusion of capacitive leakage current in the total measured leakage current.

Gate Leakage Current of Power GaAs MESFET's at High Temperature

  • Won Chang-sub;Ahn Hyungkeun;Han Deuk-Young
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.44-46
    • /
    • 2001
  • Increase of gate leakage current causes decrease of gain and increase of noise. In this paper, gate leakage current of GaAs MESEFTs' has been traced with different temperatures from $27^{\circ}C\;to\;350^{\circ}C$ to obtain the zero voltage saturation current $J_s$ which is critical to the temperature dependency of total current. From the results, thermal leakage current coefficient has been proposed to compensate for the total current due to the thermionic emission, tunneling, generation and/or hole injection.

  • PDF

Development of a Deterioration Diagnostic Device for ZnO Arrester by Leakage Current Detection (누설전류 검출에 의한 ZnO 피뢰기의 열화진단장치 개발)

  • Kim, Jae-Chul;Lee, Bo-Ho;Oh, Jung-Hwan;Lee, Young-Gil;Moon, Sun-Ho;Kim, Young-Chun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.184-189
    • /
    • 1999
  • In this paper, we develope a diagnosis device for ZnO arrester by detecting the leakage current in service. To diagnose the deterioration of ZnO arrester, the device detects the total leakage current which flows between an arrester and ground, and analyzes the resistive current(third harmonic current) which is an indicator of deterioration of ZnO arrester. We use the optical cable which can transfer a detected data without a noise, also use a microprocessor for a data storage, processing, and trend analysis. Experiment are executed to verify its performance in laboratory and the results show that the diagnosis device exactly detects the total leakage current and the resistive current, so it can diagnose the deterioration of ZnO arrester. Also the leakage current of ZnO arrester is detected using the developed diagnostic device in field, these results are presented.

  • PDF

The characteristic of leakage current of ZnO block varistor according to fault conditions of three-phase four-wire distribution system (3상 배전계통의 고장조건에 따른 산화아연 피뢰기 소자의 누설전류 특성)

  • Lee, B.H.;Choi, H.S.;Kang, S.M.;Park, K.Y.;Lee, S.B.;Oh, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.174-177
    • /
    • 2003
  • Kinds of most frequent faults happened on overhead distribution system are the single line-to-ground fault, the line-to-line fault and the two line-to-ground fault. Occasionally, the three line-to-ground fault and the disconnection of a wire are happened in severe conditions. In this study, the single line-to-ground fault, the line-to-line fault, two line-to-ground fault on three-phase four-wire overhead distribution system were experimentally simulated and characteristics of total leakage current of distribution arrester caused by these faults were investigated. Also, the changing aspect of total leakage current of distribution arrester caused by voltage variation was investigated. In a consequence, abnormal voltages caused by voltage variation, the line-to-line fault, the two line-to-ground fault have a little effect on total leakage current of ZnO arrester. But abnormal voltages caused by the single line-to-ground fault have an important effect on total leakage current of ZnO arrester.

  • PDF

Design and Fabrication of a Lightning Arrester Analyzer (피뢰기 진단장치의 설계 및 제작)

  • Kil Gyung-Suk;Han Ju-Seop;Seo Hwang-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.11
    • /
    • pp.572-576
    • /
    • 2004
  • Various devices for diagnosing arrester soundness are suggested, and most of them simply measure magnitude of leakage current. However, such kind of devices do not provide detailed information needed for the diagnosis. In this study, we designed and fabricated a new arrester analyzer by means of measuring the magnitude, the phase vs. wave height and the harmonics of total leakage currents. The analyzer is composed of a current detector, an optical linker, and a main device operated by a microprocessor. The main device is connected with leakage current detector optically not to be influenced by electromagnetic interference. The analyzer developed measures only total leakage currents, but analyzes most parameters needed for the arrester diagnostics.

Electric Fire Hazard in Low Voltage Distribution Circuits Protected by Electric Leakage Circuit Breaker(ELB) (누전차단기로 보호되는 저압선로에서의 발화위험성)

  • 홍성호;김두현
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.93-99
    • /
    • 2000
  • This paper presents a study on the assessment of electrical fire hazards by electric circuits with leakage. The hazards are evaluated with the energy supplied by earth-leakage currents which flow in the circuits simulating the actual circuit of domestic premises. Also, operating time and current of ELB are measured by an experimental approach. A common specification of ELB used in this paper has a sensitivity of 30[mA] for leakage current working on the current-balance principle. Total charges and energy of leakage currents are calculated quantitatively by a theoretical approach and compared with the results obtained from experiments.

  • PDF

Measurement Method of the Resistive Leakage Current for Lightning Arrester Diagnosis

  • Kil, Gyung-Suk;Han, Ju-Seop;Song, Jae-Yong;Seo, Hwang-Dong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.2
    • /
    • pp.63-66
    • /
    • 2005
  • Several ways for monitoring the soundness of ZnO lightning arresters have been suggested, and all of which are based on the measurement of leakage current since it is well known that the resistive leakage current is a main indicator of arrester deterioration. In this paper, we proposed an algorithm to measure the resistive leakage current, which is quite different from the conventional method that eliminates capacitive current from the total leakage current. The proposed algorithm is based on that the magnitudes of the resistive leakage current are equal at the same applied voltage levels. To confirm the reliability of the algorithm, we fabricated a leakage current detector and designed an analysis program. Experimental results showed that the method does not need a complex circuitry and is useful to analyze the resistive leakage current.

New Measurement Technique of the Resistive Leakage Current for Arrester Diagnosis (피뢰기 진단을 위한 저항분 누설전류의 새로운 측정기법)

  • Kil, G.S.;Han, J.S.;Song, J.Y.;Park, D.W.;Seo, H.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.73-75
    • /
    • 2004
  • Resistive leakage current following arresters is an important indicator of ageing, but total leakage current and its harmonic analysis are widely used in diagnosing arrester soundness because of difficulties in measuring resistive leakage current. In this paper, we proposed a new method for measuring resistive leakage current, which is quite different from the conventional methods such as a self-cancel method and a synchronous rectification method. The proposed method is based on that the magnitudes of resistive leakage currents are equal at the same voltage level. To confirm the possibility of the proposed method. we fabricated a leakage current measurement device and designed an analysis program that can analyze resistive leakage current. Comparing with other methods. this technique does not need a complex circuitry and is very simple to complete.

  • PDF

Influence of System Voltage Harmonics on Arrester Deterioration Diagnostic Techniques by Leakage Current Measurement (누설전류측정에 의한 피뢰기 열화진단기술에 있어 전원고조파의 영향)

  • Kil, Gyung-Suk;Han, Joo-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.142-145
    • /
    • 2002
  • This paper describes an influence of system voltage harmonics on arrester deterioration diagnostic techniques based on leakage current measurement because the resistive current is composed of two components caused by nonlinear characteristics of arrester and by system voltage harmonics. Resistive leakage currents of arresters, which can be evaluated by the third harmonic component of total leakage currents, increase with its deterioration progress. In this paper, we developed a PSpice model for ZnO arrester to simulate the harmonics' effect described above. In simulation, pure sinusoidal voltage and the $3^{rd}$ harmonic voltage are applied to the model, and the leakage current changes are compared. The simulation results showed that the magnitudes of resistive leakage current depend not only on the phase of system voltage harmonics but also on the magnitude of it.

  • PDF