• Title/Summary/Keyword: Tooth Profile

Search Result 237, Processing Time 0.031 seconds

A Study of Algorithm on the Freefrom Curve Gear (자유곡선 기어의 창성 알고리즘에 관한 연구)

  • 최종근
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.5
    • /
    • pp.96-101
    • /
    • 1999
  • This study suggests an algorithm for tooth profile generation of free from curve involute gear, a special gear of which the pitch line is a free curve instead of a circular one. For the first, a methodology for calculation of the tooth curve is developed and formulated Then the formulated algorithm, is programmed for manufacturing and verified by computer graphics. Next the calculated results as changed in to NC codes to apply to wire electric discharge machine(WEDM). Finally, the machined gear is examined in engagement with a standard involute gear.

  • PDF

A Study on The Tooth Creating Algorithms of The Cycloid Curve Gear and The Third Polynomial Curve Gear (사이클로이드 곡선 및 3차 다항식 곡선기어의 치형 설계에 관한 연구)

  • 최종근;윤경태
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.3
    • /
    • pp.80-85
    • /
    • 2002
  • The free curve gear is a non-circular gear without any relating center, which can perform free curve motion for complicated mechanisms, and minimize the work area. In this study, an algorithms for tooth profile generation of free curve involute gear is developed. The algorithm uses the involute gear creating principle in which a gear can be generated by rolling with another standard involute one. Cycloid me and third polynomial curve gears were designed and verified by computer graphics. These gears are manufactured in the wire-cut EDM and examined in engagement with a standard spur gear. The results showed that the proposed algorithm is successful to design and to manufacture the free curve gear with concave and convex profiles.

An Optimum Design of Herringbone Grooved Journal Bearings for Spindle Motor of Hard Disk Drive System (HDD 스핀들용 빗살무늬 저널베어링의 최적설계)

  • ;Y. Muraki;M. Tanaka
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.530-532
    • /
    • 2002
  • This paper presents an optimum design of herringbone grooved journal bearing for spindle motor of hard disk drive (HDD) system. In addition to the conventional “rectangular” groove, various groove profiles are designed. The stiffness and damping coefficients of the oil film and frictional torque are calculated and compared for tile various groove profiles. The “circular”, “valley”, and “reversed saw tooth” grooves do not produce high direct stiffness, since they partly increase the groove depths in the direction of lubricant flow, causing to reduce the pumping action of the bearing. The maximum direct stiffness can be obtained by the “rectangular”, “saw tooth”, and “step” grooves. With the same cross sectional area of the grooves, these three grooves have the same maximum stiffness, damping coefficients, and frictional torque. Among these recommendable grooves, the saw tooth groove may keep its original profile for long, enduring metal-to-metal contact during startup and shutdown.

  • PDF

Design Tool Developments of the Gerotor tooth using Matlab GUI (Matlab GUI를 활용한 Gerotor 치형 설계 도구 개발)

  • Jang, J.S.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.25-32
    • /
    • 2010
  • A geortor type pump is widely used in lubrication and actuator systems. Especially the pump is an essential machine element of an automotive engine to feed lubrication oil and power source of automatic transmission. A gerotor is a planar mechanism consist of a pair of rotor and circular tooth of stator assembly which forms a closed space. However, related industries do not have necessary technology to design and optimize the pump and paid royalties of gerotor profile on an advanced company. Also, gerotor profiles with setting design parameter have not been sufficiently analyzed from a theoretical view. Therefore, it is very difficult for designer to decide the specifications of the gerotor profiles, and calculation and fluctuation of flow rate is not yet confirmed. In this study, theoretical analyses and optimal design of the gerotor profiles have been performed numerical method by mathematical base. An automated design system of the tooth profile has been developed through MATLAB GUI Program considering various design parameters.

  • PDF

Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique (프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발)

  • Ullah, Furqan;Lee, Gunn-Soo;Park, Kang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

A Study on the Improvement of Transmission Error and Tooth Load Distribution using Micro-geometry of Compound Planetary Gear Reducer for Tractor Final Driving Shaft (트랙터 최종구동축용 복합유성기어 방식 감속기의 Micro-geometry를 이용한 전달 오차 및 치면 하중 분포 개선에 관한 연구)

  • Lee, Nam Gyu;Kim, Yong Joo;Kim, Wan Soo;Kim, Yeon Soo;Kim, Taek Jin;Baek, Seung Min;Choi, Yong;Kim, Young Keun;Choi, Il Su
    • Journal of Drive and Control
    • /
    • v.17 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • This study was to develop a simulation model of a compound planetary gear reducer for the final driving shaft using a gear analysis software (KISSsoft, Version 2017, KISSsoft AG, Switzerland). The aim of this study is to analyze transmission error and the tooth load distribution through micro-geometry using the simulation model. The tip and root relief were modified with Micro-geometry in the profile direction, and crowning was modified with Micro-geometry in the lead direction. The transmission error was analyzed using the PPTE (Peak to Peak Transmission Error) value, and the tooth load distribution was analyzed for the concentrated stress on the tooth surface. As a result of modifying tip and relief in the profile direction, the transmission error was reduced up to 40.7%. In the case of modifying crowning in the lead direction, the tooth load was more evenly distributed than before and decreased the stress on the tooth surface. After modifying the profile direction for the 1st and 2nd planetary gear train, the bending and contact safety factors were increased by 31.7% and 17%, and 18.3% and 12.5% respectively. Moreover, the bending and safety factors after modifying lead direction were increased by 59.5% and 32.7%, respectively for the 1st planetary gear train, and 59.6% and 43.6%, respectively for the 2nd planetary gear train. In future studies, the optimal design of a compound planetary gear reducer for the final driving shaft is needed considering both the transmission error and tooth load distribution.

LIP PROFILE CHANGES AFTER ORTHODONTIC TOOTH MOVEMENT IN FEMALE ADULT WITH BIMAXILLARY PROTRUSION (양악 전돌증 환자에서 소구치 발치를 통한 교정치료시 입술 주위 연조직변화에 관한 연구)

  • Kim, Tae-Kyung;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.24 no.1 s.44
    • /
    • pp.135-147
    • /
    • 1994
  • Facial esthetics is one of the most important goal of the orthodontic treatment and main concern of many patients. Facial esthetics should be considered in orthodontic diagnosis and treatment planning. Prediction of soft tissue profile changes after orthodontic tooth movement should be considered as well. The purpose of this study was to find out the effect of orthodontic treatment on lip profile in adult patient. The pre and post treatment cephalometric roentgenograms of 87 female adult with bimaxillary protrusion were used to analyze lip profile change. All subjects were treated with four bicuspids extraction. Obtained results were as follows . 1. Lip thickness changes after incisor retraction showed different patterns according to areas of the lip. The thickness of the red lip area showed 2.78 mm increase in average. In contrast the thickness of the cutaneous area showed 0.65 - 0.7 mm decrease according to the different cutaneous areas. 2. The length of the red lip area decreased(1.3mm) after incisor retraction. 3. The length of the cutaneous lip area increased(2.9mm) after incisor retraction.

  • PDF

Development and Design of Robot Speed Reducer(RSR) with Straight Line Teeth Profile for Human Robot (휴먼 로봇을 위한 직선 치형을 갖는 로봇 감속기(RSR)의 설계 및 개발)

  • Nam Won-Ki;Jang In-Hun;Oh Se-Hoon;Shin Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.3
    • /
    • pp.315-320
    • /
    • 2006
  • There are many types of reduction drives for industrial applications. In general, high precision speed reducer which has a cycloid or involute teeth profile, used to in robot. Because, it is essential to use precision reduction drives for accuracy of position control on robot system. In this paper, we propose a robot speed reducer(RSR) with straight line teeth profile, which has basically a triangle teeth profile. In new straight line teeth profile, we have a good result for strength, stress and stiffness by using finite element analysis and the results indicate that variation of eccentric coefficient affects the optimal tooth motion, and it can lower the stress and noise.

The Use of Ovate Pontics in the Maxillary Anterior Esthetic Zone: A Clinical Report (Ovate Pontic을 이용한 상악 전치부 심미수복)

  • Choi, Mee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.23-29
    • /
    • 2009
  • The ovate pontic was first described by Dewey and Zugsmith in 1933, but used clinically as a clinical alternative for esthetics in the late 1990s. The ovate pontic has been suggested as a more accurate duplication of emergence profile for natural teeth to provide an esthetic, cleanable prosthesis. If the resin temporary prosthesis with the ovate pontic is used during the healing period after the tooth extraction, it is possible to preserve the interdental papilla and eliminate or minimize the black triangle between the teeth. Ultimately it can become a esthetic final restoration without saliva leakage and phonetic discomfort. In this case we tried to treat the maxillary anterior area by the use of the ovate pontic and minimize the loss of the interdental papilla via duplicate the emergence profile of the natural tooth.

Stress Concentration FEM Simulation of Robot Speed Reducer(RSR) with Straight Line Teeth Profile (직선 치형을 가진 로봇 감속기(RSR)의 응력 집중 FEM 해석)

  • Nam, Won-Ki;Kook, Chang-Ho;Ham, Seong-Hun;Jang, In-Hun;Oh, Se-Hoon;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.7
    • /
    • pp.952-956
    • /
    • 2007
  • In industrial site, as the technology of FA developes, many robots can take the place of human labor. Generally, robots require high precision reducers which have cycloid or involute tooth profile. These reducers provide high reduction ratios with low backlash and high accuracy but need a high stiffness of tooth. In this study, to improve the high precision, the cycloid reducers which have straight line teeth profile are used. Also the FEM analysis, which consist of straight line teeth profile, was performed to simulate the stress of teeth profile.