• Title/Summary/Keyword: TomoTherapy

Search Result 34, Processing Time 0.021 seconds

Evaluation of 3DVH Software for the Patient Dose Analysis in TomoTherapy (토모테라피 환자 치료 선량 분석을 위한 3DVH 프로그램 평가)

  • Song, Ju-Young;Kim, Yong-Hyeob;Jeong, Jae-Uk;Yoon, Mee Sun;Ahn, Sung-Ja;Chung, Woong-Ki;Nam, Taek-Keun
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.201-207
    • /
    • 2015
  • The new function of 3DVH software for dose calculation inside the patient undergoing TomoTherapy treatment by applying the measured data obtained by ArcCHECK was recently released. In this study, the dosimetric accuracy of 3DVH for the TomoTherapy DQA process was evaluated by the comparison of measured dose distribution with the dose calculated using 3DVH. The 2D diode detector array MapCHECK phantom was used for the TomoTherapy planning of virtual patient and for the measurement of the compared dose. The average pass rate of gamma evaluation between the measured dose in the MapCHECK phantom and the recalculated dose in 3DVH was $92.6{\pm}3.5%$, and the error was greater than the average pass rate, $99.0{\pm}1.2%$, in the gamma evaluation results with the dose calculated in TomoTherapy planning system. The error was also greater than that in the gamma evaluation results in the RapidArc analysis, which showed the average pass rate of $99.3{\pm}0.9%$. The evaluated accuracy of 3DVH software for TomoTherapy DQA process in this study seemed to have some uncertainty for the clinical use. It is recommended to perform a proper analysis before using the 3DVH software for dose recalculation of the patient in the TomoTherapy DQA process considering the initial application stage in clinical use.

Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy (전뇌 방사선치료 시 치료방법에 따른 두피선량평가)

  • Jang, Joon-Yung;Park, Soo-Yun;Kim, Jong-Sik;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.103-108
    • /
    • 2011
  • Purpose: Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Materials and Methods: Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). Results: When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Conclusion: Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  • PDF

A Method to Calculate a Pass Rate of the ${\gamma}$-index Analysis in Tomotherapy Delivery Quality Assurance (DQA) (단층치료기를 이용한 방사선 치료의 환자별 정도관리 평가를 위한 감마인덱스의 정량화 방법)

  • Park, Dahl;Kim, Yong-Ho;Kim, Won-Taek;Kim, Dong-Won;Kim, Dong-Hyun;Jeon, Ho-Sang;Nam, Ji-Ho;Lim, Sang-Wook
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.340-347
    • /
    • 2010
  • DQA, a patient specific quality assurance in tomotherapy, is usually performed using an ion chamber and a film. The result of DQA is analysed with the treatment planning system called Tomo Planning Station (TomoPS). The two-dimensional dose distribution of film measurement is compared with the dose distribution calculated by TomoPS using the ${\gamma}$-index analysis. In ${\gamma}$-index analysis, the criteria such as 3%/3 mm is used and we verify that whether the rate of number of points which pass the criteria (pass rate) is within tolerance. TomoPS does not provide any quantitative information regarding the pass rate. In this work, a method to get the pass rate of the ${\gamma}$-index analysis was suggested and a software PassRT which calculates the pass rate was developed. The results of patient specific QA of the intensity modulated radiation therapy measured with I'mRT MatriXX (IBA Dosimetry, Germany) and DQA of tomotherapy measured with film were used to verify the proposed method. The pass rate was calculated using PassRT and compared with the pass rate calculated by OmniPro I'mRT (IBA Dosimetry, Germany). The average difference between the two pass rates was 0.00% for the MatriXX measurement. The standard deviation and the maximum difference were 0.02% and 0.02%, respectively. For the film measurement, average difference, standard deviation and maximum difference were 0.00%, 0.02% and 0.02%, respectively. For regions of interest smaller than $24.3{\times}16.6cm^2$ the proposed method can be used to calculate the pass rate of the gamma index analysis to one decimal place and will be helpful for the more accurate DQA in tomotherapy.

Study of the CatcherTM Couch's Usefulness (토모치료기 CatcherTM Couch의 유용성에 대한 고찰)

  • Um, Ki Cheon;Lee, Chung Hwan;Jeon, Soo Dong;Song, Heung Kwon;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.65-74
    • /
    • 2019
  • Purpose: Recently, A Catcher was added to prevent sagging in Radixact® X9. In this study, We quantitatively compared general couch of Tomo-HDA® with catcher couch of Radixact® X9 using the human phantom and evaluated usefulness of catcher. Materials and methods: We used rando phantom for phantom study and set the each iso-center of head and neck region and Pelvis region for region parameter. Furthermore, We used hand made low melting point alloys for weight parameter. MVCT(Mega Voltage Computed Tomography) images were acquired for vertical error and rotation(pitch) error measurement increasing weight(A: 15kg, A+B: 30kg, A+B+C: 45kg). We selected 120 patients who has been treated using Tomotherpy machine for patient study. 60 patients has been treated in Tomo-HDA® and the other 60 patients treated in Radixact® X9. In the patient study methods, vertical error and rotation(pitch) error was measured for mean value calculation using MVCT images acquired on first day of radiation therapy. Result: Result of phantom study, Vertical error and rotation(pitch) error was increased proportionally increased as the weight increases in general couch of Tomo-HDA®. each maximum value was 7.52mm, 0.38° in head and neck region and 11.94mm, 0.92° in pelvis region. However, We could confirm that there was stable error range(0.02~0.1mm, 0~0.04°) in Catcher couch of Radixact®. Result of patient study, The head and neck region was measured 4.79mm 0.33° lower, and the pelvis region was measured 7.66mm, 0.22° lower in Catcher couch of Radixact® X9. Conclusion: In this study, Vertical error and rotation(pitch) error was proportionally increased as the weight increases in general couch of Tomo-HDA®. Especially, The pelvis region error was more increased than the head and neck region error. However, Vertical error and rotation(pitch) error was regularly generated regardless of weight or regions in CatcherTM couch of Radixact® X9 that this study's purpose. In conclusion, CatcherTM couch of Radixact® X9 can minimize mechanical error that couch sagging. Furthermore, The pelvis region is more efficiency than head and neck region. In radiation therapy using Tomotherapy machine, it is regarded that may contribute to minimizing unadjusted pitch error due to characters of Tomotherapy.

Impact of the Respiratory Motion and Longitudinal Profile on Helical Tomotherapy

  • Park, So Hyun;Choi, Jinhyun;Kim, JinSung;Ahn, Sohyun;Kim, Min Joo;Lee, Ho;Choi, Seo Hee;Park, Kwangwoo
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • The $TomoTherapy^{(R)}$ beam-delivery method creates helical beam-junctioning patterns in the dose distribution within the target. In addition, the dose discrepancy results in the particular region where the resonance by pattern of dose delivery occurs owing to the change in the position and shape of internal organs with a patient's respiration during long treatment times. In this study, we evaluated the dose pattern of the longitudinal profile with the change in respiration. The superior-inferior motion signal of the programmable respiratory motion phantom was obtained using AbChes as a four-dimensional computed tomography (4DCT) original moving signal. We delineated virtual targets in the phantom and planned to deliver the prescription dose of 300 cGy using field widths of 1.0 cm, 2.5 cm, and 5.0 cm. An original moving signal was fitted to reflecting the beam delivery time of the $TomoTherapy^{(R)}$. The EBT3 film was inserted into the phantom movement cassette, and static, without the movement and with the original movement, was measured with signal changes of 2.0 s, 4.0 s, and 5.0 s periods, and 2.0 mm and 4.0 mm amplitudes. It was found that a dose fluctuation within ${\pm}4.0%$ occurred in all longitudinal profiles. Compared with the original movement, the region of the gamma index above 1 partially appeared within the target and the border of the target when the period and amplitude were changed. Gamma passing rates were 95.00% or more. However, cases for a 5.0 s period and 4.0 mm amplitude at a field width of 2.5 cm and for 2.0 s and 5.0 s periods at a field width of 5.0 cm have gamma passing rates of 92.73%, 90.31%, 90.31%, and 93.60%. $TomoTherapy^{(R)}$ shows a small difference in dose distribution according to the changes of period and amplitude of respiration. Therefore, to treat a variable respiratory motion region, a margin reflecting the degree of change of respiration signal is required.

Analysis of Pitch and Yaw Deviations Using an Aid-Pillow for the Head and Neck Cancer on the TomoTherapy (토모테라피를 이용한 두경부암 방사선치료에서 Aid-pillow 사용에 따른 Pitch와 Yaw의 변화 분석)

  • Jung, Jae Hong;Cho, Kwang Hwan;Kim, Yong Ho;Moon, Seong Kwon;Min, Chul Kee;Kim, Eun Seog;Lee, Kyung-Bae;Jung, Joo-Young;Suh, Tae-Suk;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.54-60
    • /
    • 2013
  • The aim of this study was to analysis of the pitch and yaw deviations with or without using an aid-pillow for the head and neck cancer on the TomoTherapy. A total of 14 head and neck patients were selected to without-group (n=7) and with-group (n=7). A total of 333 MVCT image sets used to evaluate the translational (lateral, longitudinal and vertical) and rotational adjustments (pitch, roll and yaw) with 153 and 180 MVCT image sets at without- and with-group, respectively. Deviations of without- and with-groups were $0.12^{\circ}$ and $0.09^{\circ}$, respectively at pitch. And, deviations without- and with-groups were $0.47^{\circ}$ and $0.17^{\circ}$, respectively at yaw. In generally, with-group had reduced than without-group for the pitch and yaw deviations. Therefore, using an aid-pillow, it will able to increase the reproducibility of treatment for the head and neck cancer patients on the TomoTherapy.

In Tomotherapy, for the Maintenance of Body Temperature due to Substance Use, Changes in Dose Assessment in the Organization (TOMO 치료 시 체온 유지를 위한 물질 사용에 따른 조직 내 선량 변화 평가)

  • Hwang, Jae-Woong;Jeong, Do-Hyeong;Kim, Dae-Woong;Yang, Jin-Ho;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.131-134
    • /
    • 2010
  • Purpose: TOMO therapy treatment for a relatively long run Beam time and temperature-sensitive detector, such as CT clinics in optimal temperature ($20~21^{\circ}$) to maintain a constant temperature in addition to its own Chamber Cooling system is activating. TOMO This clinic has been reduced in the patients' body temperature to keep the sheets and covers over the treated area. Therefore, these materials for any changes in the organization gives the dose were analyzed. Materials and Methods: To compare changes in the organization Dose Phantom cheese (Cheese Phantom) were used, CT-simulation taking the center point of the cheese phantom PTV (Planning Target Volume, treatment planning target volume) by setting Daily dose 200 cGy, 3 meetings planned treatment. PTV, PTV +7 cm, PTV +14 cm, the total count points on the phantom using the Ion chamber cover without any substance to measure the dose, and one of the most commonly used treatment, including the frequently used four kinds of bedding materials (febric 0.8 mm, gown 1.4 mm, rug, 3.3 mm, blanket 13.7 mm) and covered with a phantom and the dose measured at the same location were analyzed 3 times each. Results: PTV, PTV +7 cm, PTV +14 cm from the point of any substance measured in the state are covered with four kinds of materials (fabric, gown, rug, blanket) was measured in the covered states and compares their results, PTV respectively -0.17%, -0.44%, -0.53% and -0.9% change, PTV +7 cm, respectively -0.04%, +0.07%, +0.06%, +0.07%, were changed, PTV +14 cm, respectively 0%, -0.06%, -0.02%, +0.6%, respectively. Conclusion: These results TOMO treatment to patients to maintain their body mass by using PTV thickness of the material decreased in proportion to. PTV +7 cm, but showed slight changes in the point, PTV +14 cm at the point of the dose was increased a little. Sejijeom all the difference in treatment tolerance ${\pm}3%$ range, this is confirmed in the coming treatment will not affect the larger should be considered.

  • PDF

Usability Assessment of Plan Transfer between TOMO HAD and Radixact : Planning Study (TOMO HDA와 Radixact 치료 계획 간 Transfer에 대한 유용성 평가 : Planning Study)

  • An, Ye Chan;Kim, Jong Sik;Kwon, Dong Yeol;Kim, Jin Man;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.117-128
    • /
    • 2018
  • Purpose : To evaluate the usability of plan transfer between TOMO HD and Radixact, we compared the differences of dose in transferred plans by evaluating the dose of normal organ and target. TOMO HDA and Radixact. The completed plans were transferred each other and we compared the differences of dose by evaluating the DVH of each plans. Materials and Methods : We planned 4 different plans assuming the treatment of 2 cases in Head and Neck Cancer and 2 cases Prostate cancer. Each plan was designed so that 95 % of the prescription dose was irradiated over 99 % of the target volume, and the normal organ constraints dose was based on the SMC tolerance dose protocol. Each plan was transferred to each equipment and DVH(dose volume histogram) analysis of the transferred plans was compared and evaluated. Results : The Mean dose of CTV and GTV was increased and decreased in the transferred plans, but there was no significant differences. The target coverage of CTV and GTV was decreased in all cases of transferred plans from TOMO HAD to Radixact, and the change of CI and HI in CTV was within 0.1. Normal organ dose was increased in most cases when transferring from HAD to Radixact in both treatment plans. Conclusion : According to the results of this experiment, the target coverage was above the standard and the normal organ dose was almost same or decreased when transferring the plans from Radixact to HDA equipment. However the target coverage was reduced when transferring the plans from HDA to Radixact and there was an increase in dose in normal organs that could cause sever side effects such as Optic Chiasm ($D_{max}$1.38 Gy), Bladder ($D_{max}$3.07 Gy), Penile Bulb ($D_{max}$1.14 Gy). Therefore, it is necessary to pay attention to the dose change when transferring the plan and one-time transfer due to equipment inspection will be useful for efficient radiation therapy, but if the transferred treatment plans continue for several consecutive days, the treatment plan should be resumed.

  • PDF

Dosimetric and clinical review on the application of TOMO_edge mode (토모테라피 Edge 모드를 이용한 임상적 유용성 고찰)

  • Kim, Lizzy
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.177-182
    • /
    • 2014
  • Purpose : The goal of this study was to compare and analysis the dose distribution and treatment time between Tomotherapy planning with fixed jaw(FJ) and dynamic jaw(DJ). Materials and Methods : Seven patients were selected in the study including five common clinical cases(brain, head and neck(HN), lung, prostate, spine). 1) Helical Tomotherapy plans with FJ and DJ were generated with the same planning parameters such as Modulation factor, Pitch and Field width. 2) Tomo_edge plans with a larger field width were generated to compare to conventional HT delivery with fixed jaw. Dosimetric evaluation indices for target coverage are Dmin, Conformity index(CI) and for whole body including target are $V_{10%}$, $V_{25%}$, $V_{50%}$, $V_{75%}$ using Dose-volume histogram(DVH). Also, Treatment time and Cumulative MU were used for clinical review on Tomo_edge. Results : In case of using the same field width of Tomotherapy planning with FJ and DJ, the averaged variations were $V_{10%}$: -11.91%, $V_{25%}$: -7.6%, $V_{50%}$ :-4.75%, $V_{75%}$: -1.04%. Tomo_edge with a larger field width provides the averaged variations for target coverage: Dmin: -0.72%, CI: -1.25% and also shows the tendency of a sharp $V_{x%}$ decline in low dose area. The clinical improvements in the larger field width with DJ were observed in the treatment time, ranging from -51.21% to -15.11, and the Cumulative MU decrease, ranging from -57.74% to -15.31%. Conclusion : Target coverage achieved by FJ and DJ with the same field width has little differences. But integral doses on whole body efficiently decreased. Compared to the conventional HT delivery, Tomo_edge with a larger field width presents a little worse target coverage. However, it provides faster treatment delivery and improved cranial-caudal target dose conformity. Therefore, Tomo_edge mode is efficient in improving the treatment time and integral dose while maintaining comparable plan quality in clinic.

Verification of skin dose according to the location of tumor in Tomotherapy (토모테라피 시 종양의 위치에 따른 피부선량 검증)

  • Yoon, Bo Reum;Park, Su Yeon;Park, Byoung Suk;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • Purpose : To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. Materials and Methods : In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5mm and 10mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3mm and 5mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. Results : The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5mm and 3mm respectively. If placed 5mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5mm and 3mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2~17.1% whereas if the tumor is 5mm away from the ceiling part, the figure decreased to 2.8~9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment. Conclusion : This study found gaps between planned skin doses and actual doses in the Tomotherapy treatment planning. Especially to the Tomo-cocuh direction, skin doses were found to be larger than the planned doses. Thus, during the treatment of tumors near the Tomo-couch, doses will need to be more accurately calculated and more efforts to verify skin doses will be required as well.