• 제목/요약/키워드: Titration

검색결과 608건 처리시간 0.029초

PC 카메라를 이용한 수돗물의 과망간산칼륨소비량 적정 자동화 (Automatic Titration for KMnO4 Consumption Test of Tap Water Using Personal Computer Camera)

  • 이형춘
    • 한국환경보건학회지
    • /
    • 제34권1호
    • /
    • pp.95-100
    • /
    • 2008
  • An automatic titration system using a PC-camera with a color filter on its lens was used in the $KMnO_4$ consumption test of tap water and distilled water in relation to blank tests. The very faint pink color of titration end point could be effectively detected by using a yellow cellophane paper as a color filter. The average hue value (Havg) of 192 pixels in the image of the sample solution being titrated was computed and followed up at regular time intervals during titration in order to detect the titration end point. The Havg decrease of 2 degrees from the average of first 10 Havgs was regarded as reaching the end point. The volume of 0.01N $KMnO_4$ consumed by a tap water sample was $0.728{\pm}0.022ml$ in manual titration and $0.735{\pm}0.013ml$ in automatic titration (p=0.580). The volume of 0.01N $KMnO_4$ consumed by a distilled water sample was $0.383{\pm}0.015ml$ in manual titration and $0.367{\pm}0.015ml$ in automatic titration (p=0.252). The high p-values for t-test suggested that there were good agreements between manual and automatic titration data and the automatic method proposed in this article was considered to effectively replace the manual titration.

미량확산법에 의한 휘발성염기질소 분석에서 PC카메라를 이용한 자동적정 (Automatic Titration Using PC Camera in Volatile Basic Nitrogen Analysis by Microdiffusion Method)

  • 이형춘
    • 한국식품영양과학회지
    • /
    • 제34권1호
    • /
    • pp.135-137
    • /
    • 2005
  • 미량확산법에 의한 휘발성염기질소 분석에서 PC카메라를 이용하여 자동적정하기 위하여 자동적정시스템을 구성하였으며, 자동적정프로그램을 작성하였다. 자동적정방법은 피적정액 화상 중 마우스 포인터에 의하여 지정된 화소의 Green값과 Red값이 적정종말점에서 서로 반전되는 것을 이용하였다. 돈육시료를 사용하여 실험한 결과 부패도가 다른 모든 시료에서 자동적정과 수동적정간에 유의차가 인정되지 않았으며, 서로간에 높은 상관성이 있었고 잘 일치하였다.

PC 카메라를 이용한 식초, 우유 및 탁주의 산도 적정 자동화 (Automatic Titration Using PC Camera in Acidity Analyses of Vinegar, Milk and Takju)

  • 이형춘
    • 한국식품영양과학회지
    • /
    • 제36권12호
    • /
    • pp.1583-1588
    • /
    • 2007
  • PC 카메라를 이용하여 식초, 우유 및 탁주의 산도 적정을 자동화하였다. 피적정액의 화상에서 선택된 144개 pixel의 hue값의 평균값을 일정 시간 간격으로 산출하고, 이 평균값의 변화를 추적하여 적정액의 공급을 제어하는 방법을 사용하였다. 식초와 우유의 적정에서는 hue값 평균값이 적정전보다 5이상 증가하는 것을 종말점으로 하였으며, 탁주의 경우에는 70이상 증가하는 것을 종말점으로 하였다. 이 방법을 식초, 우유 및 탁주의 산도 적정에 적용한 결과, 식초의 경우에는 수동적정과 자동적정의 0.1 N NaOH용액의 소요량이 각각 $21.409{\pm}0.066mL$$21.403{\pm}0.055mL$였고, t-test 결과 p값이 0.841이었다. 우유의 경우에는 수동적정과 자동적정의 0.1 N NaOH용액의 소요량이 각각 $1.390{\pm}0.025mL$$1.388{\pm}0.027mL$였고, p값은 0.907이었다. 탁주의 경우에는 수동적정과 자동적정의 0.1 N NaOH용액의 소요량이 각각 $4.738{\pm}0.028mL$$4.752{\pm}0.037mL$였고, p값은 0.518이었다. 세가지 경우 모두 유의수준 0.05에서 유의차가 인정되지 않았으므로(p>0.05), 본 연구의 자동적정 방법을 산도 적정에 응용할 수 있다고 생각되었으며, 색변화를 이용하여 종말점을 검출하는 대부분의 적정에 무리 없이 적용할 수 있다고 생각되었다.

위상각 측정에 의한 적정의 정확한 종말점 검출법에 관한 연구 (A Study on the Precise End-Point Detection in Titration by Using the Phase Angle Measurements)

  • 박병빈;신호상;이한형
    • 분석과학
    • /
    • 제12권4호
    • /
    • pp.290-298
    • /
    • 1999
  • 임피던스 위상각 적정법을 산화환원적정, 산염기적정, 착화적정 그리고 침전적정에 적용하여 정확한 종말점 검출법을 연구하였다. 일정한 교류전류가 두 백금전극사이를 통과하도록 하였고 그중 하나는 $0.1cm^2$ 또는 $0.026cm^2$의 표면적을 가진 초소형 분극전극이었고 다른 하나는 $1cm^2$의 표면적을 비분극전극을 사용하였다. 과망간산칼륨에 의한 옥살산의 산화환원적정에서 임피던스 위상각 적정법을 적용하였을때 $50{\mu}A$, 0.0005 M 이상의 농도에서 뚜렷한 종말점을 얻었고, 50 Hz 근방의 주파수 영역에서 가장 확실한 종말점을 얻을 수 있었다. NaOH에 의한 인산의 산염기 적정에서 0.001 M 수산화나트륨에 의한 0.001 M 인산의 적정시 임피던스 위상각 적정법을 적용하여 $50{\mu}A$, 주파수 25-97 Hz의 넓은 주파수 영역에서 뚜렷한 제1당량점을 얻었다. 이는 전도도의 반대 개념으로서의 임피던스의 변화량이 종말점을 기점으로 변곡하고 이에따라 위상각이 변화하는데 원인됨을 알았다. 또한 제2당량점에서는 임피던스 위상각 적정법으로 뚜렷한 종말점을 얻지 못하였다. 이는 $Na_2HPO_4$의 가수분해를 막기 위하여 적정시 과량으로 첨가되는 NaCl에 의한 방해로 생각된다. 0.1 M EDTA에 의한 0.01 M 황산구리의 착화적정시에는 위상각 측정으로 적정종말점을 찾기 보다는 "다른위상" 임피던스 Z"을 측정하여 종말점을 알아내는 것이 유리함을 알았다. $AgNO_3$에 의한 $Cl^-$의 침전적정에 있어 $100{\mu}A$, 0.1 M 농도에서 임피던스 위상각 적정법을 적용하여 명확한 종말점을 얻었고, 15-30Hz 범위에서 가장 안정적인 뚜렷한 변화를 볼 수 있었다. 그러나 0.01 M 농도에서는 임피던스 위상각의 뚜렷한 변화를 볼 수 없었다. 본 연구에서 임피던스 위상각 적정법을 산화환원적정, 산염기적정, 착화적정 그리고 침전적정시의 종말점 검출을 위해 사용하였을 때 대부분 성공적이었으며 이는 적정시 종말점을 정확히 측정하는 목적에 활용 할수 있음을 보여주는 것이다.

  • PDF

Characterization of Poly(styrene-b-vinylbenzylphosphonic acid) Copolymer by Titration and Thermal Analysis

  • Kim, Sang-Hun;Park, Young-Chul;Jung, Gui-Hyun;Cho, Chang-Gi
    • Macromolecular Research
    • /
    • 제15권6호
    • /
    • pp.587-594
    • /
    • 2007
  • Well defined amphiphilic diblock copolymers of poly(styrene-b-vinylbenzylphosphonic acid) (PS-b-PVBPA) were prepared by controlled radical polymerization technique, two-step hydrolysis reactions using trime-thylsilyl bromide from the corresponding phosphonic ethyl ester. By indirect, backward pH titration of the block copolymer, a good titration curve of a dibasic acid was observed. The IEC values obtained from both backward pH titration and volumetric back titration were almost identical. Thermal gravimetric analysis (TGA) of the phosphonic acid containing block copolymer showed a high thermal stability up to $400^{\circ}C$.

Principles and Applications of Galvanostatic Intermittent Titration Technique for Lithium-ion Batteries

  • Kim, Jaeyoung;Park, Sangbin;Hwang, Sunhyun;Yoon, Won-Sub
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권1호
    • /
    • pp.19-31
    • /
    • 2022
  • Lithium-ion battery development is one of the most active contemporary research areas, gaining more attention in recent times, following the increasing importance of energy storage technology. The galvanostatic intermittent titration technique (GITT) has become a crucial method among various electrochemical analyses for battery research. During one titration step in GITT, which consists of a constant current pulse followed by a relaxation period, transient and steady-state voltage changes were measured. It draws both thermodynamic and kinetic parameters. The diffusion coefficients of the lithium ion, open-circuit voltages, and overpotentials at various states of charge can be deduced by a series of titration steps. This mini-review details the theoretical and practical aspects of GITT analysis, from the measurement method to the derivation of the diffusivity equation for research cases according to the specific experimental purpose. This will shed light on a better understanding of electrochemical reactions and provide insight into the methods for improving lithium-ion battery performance.

산화-환원 적정 곡선 (Oxidation-Reduction Titration Curve Both Half Reactions Homogeneous in Coefficient)

  • 최규원
    • 대한화학회지
    • /
    • 제11권4호
    • /
    • pp.159-164
    • /
    • 1967
  • 균일계수 산화환원 적정에 있어서의 전위의 적정분율에 따른 변화을 나타내는 정확한 방정식을 얻었다. 이 방정식은 정정곡선이 시약의 농도에 무관계함을 알려준다. 또한 전위차적정범위 종말점의 예민도는 반전지의 기준전위의 차는 몰론, 각 반반응에 관여하는 전자수에 따라 심한 영향을 받음을 알려준다. 적정곡선의 변곡점이 당량점과 일치하지 않음을 증명하였다. 또한 적정단계에 따른 반응의 완결도를 평형상수식을 토대로 하여 해석하였다. 이 결과는 산화환원 이외의 평형에도 적용된다.

  • PDF

수두바이러스의 정량에 있어서 Solid-overlay Standard Plaque Assay와 Immunofocus Assay의 효용성 비교 연구 (Comparative Study of the Standard Plaque Assay with Solid-overlay and Immunofocus Assay for Varicella-zoster Virus Titration)

  • 이화경;정용석
    • 대한바이러스학회지
    • /
    • 제30권1호
    • /
    • pp.61-70
    • /
    • 2000
  • Standard plaque assay using agarose-overlay has long been used for titration of many infectious virus particle. Plaque assay for the titration of varicella-zoster virus and its live vaccine requires three intermittent agarose overlay to visualize plaques. Overall procedure of the assay takes at least nine days from virus inoculation and microbe contamination including fungi is frequently accompanied during incubation period. We studied whether an immunofocus assay in conjunction with peroxidase-mediated immunohistochemical reaction may replace the standard plaque assay for the virus titration by comparing the two methods. A linear relationship was observed between number of foci and virus dilution. The number of foci in a given dilution of virus appeared a little higher than counted plaques formed in standard plaque assay. Independent titration results obtained from two assay methods for a given dilution of virus demonstrated a strong correlation ($r^2=0.99$). Foci of virus infected cells as revealed by the enzyme reaction could be counted either 4 days post-infection (p.i.) under low magnification (40X) microscopy, or 6 days p.i. by naked eye observation. Larger size of cell cuture plate, virus adsorption at $35^{\circ}C$, and 10% FBS in diluent appeared to be better conditions for the assay. Immunofocus assay will be an effective and dependable titration method for varicella-zoster virus and its live vaccine in place of the standard plaque assay in respect to accuracy, costs, and experimental convenience.

  • PDF

한국인 폐쇄성 수면 무호흡 환자의 적정 양압을 위한 수동화 양압 측정법과 자동화 양압 측정법의 비교 (Comparison for the Optimal Pressure between Manual CPAP and APAP Titration with Obstructive Sleep Apnea Patients)

  • 김대진;최병걸;조재욱;문수진;이민우;김현우
    • 대한임상검사과학회지
    • /
    • 제51권2호
    • /
    • pp.191-197
    • /
    • 2019
  • 폐쇄성 수면 무호흡 환자들의 양압기 사용을 위한 적정 양압측정은 편리함과 경제성뿐만 아니라 다양한 원인으로 CPAP 측정법보다는 APAP 측정법을 더 선호한다. 그러나 PSG 감시하에 진행하는 CPAP 측정법보다 정확성에 대한 의문이 아직까지 남아있다. 이에 본 연구에서는 동일한 대상자에 대한 CPAP과 APAP 측정법의 적정 압력과 무호흡-저호흡 지수를 변수로서 두 방법간의 효율성과 정확성을 비교하였다. 대상자는 분할 수면다원검사 중 CPAP 양압 측정과 7일 이상 APAP 양압 측정에 성공한 79명이 모집되었다. CPAP과 APAP 측정법의 적정 양압은 $7.0{\pm}1.8cmH_2O$, $7.6{\pm}1.6cmH_2O$ 무호흡-저호흡 지수는 $1.3{\pm}1.5/h$, $3.0{\pm}1.7/h$로 CPAP 측정법이 두 변수 모두 통계적으로 유의하게 낮게 나타났다(P<0.001). 그러나 미국수면학회 가이드라인 무호흡-저호흡 지수 5/h이하의 적정 양압 도달 비율은 CPAP 측정법이 96.2% (76명), APAP 측정법이 94.9% (75명)으로 유의미한 차이를 보이지 않았다(r=-0.045, P=0.688). 본 연구를 요약하면, CPAP은 APAP 측정법보다 좀 더 효율적인 측정법으로 나타났다. 그렇지만 적정 양압에 도달하는 비율은 두 방법 모두 통계적 차이를 나타내지 않아 정확성을 가진다. 따라서 CPAP과 APAP 측정법 중 요구되는 상황에 따라 적절한 방법을 선택하여 적정 양압을 측정할 수 있겠다.