• Title/Summary/Keyword: Tip size

Search Result 611, Processing Time 0.027 seconds

Comparison of three digital radiographic imaging systems for the visibility of endodontic files (근관 파일의 인지도 평가시 세 가지 디지털 방사선영상시스템의 비교)

  • Park Jong-Won;Kim Eun-Kyung;Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.145-150
    • /
    • 2004
  • Purpose: To compare three digital radiographic imaging sensors by evaluating the visibility of endodontic file tips with interobserver reproducibility and assessing subjectively the clarity of images in comparison with the x-ray film images. Materials and Methods: Forty-five extracted sound premolars were used for this study. Fifteen plaster blocks were made with three premolars each and #8, 10, 15 K-flexofiles were inserted into the root canal of premolars. They were radiographically exposed using periapical x-ray films (Kodak Insight Dental film, Eastmann Kodak company, Rochester, USA), Digora imaging plates (Soredex-Orion Co., Helsinki, Finland), CDX 2000HQ sensors (Biomedisys Co., Seoul, Korea), and CDR sensors (Schick Inc., Long Island, USA). The visibility of endodontic files was evaluated with interobserver reproducibility, which was calculated as the standard deviations of X, Y coordinates of endodontic file tips measured on digital images by three oral and maxillofacial radiologists. The clarity of images was assessed subjectively using 3 grades, i.e. plus, equal, and minus in comparison with the conventional x-ray film images. Results: Interobserver reproducibility of endodontic file tips was the highest in CDR sensor (p < 0.05) only except at Y coordinates of #15 file. In the subjective assessment of the image clarity, the plus grade was the most frequent in CDR sensor at all size of endodontic file (p < 0.05). Conclusion : CDR sensor was the most superior to the other sensors, CDX 2000HQ sensor and Digora imaging plate in the evaluation of interobserver reproducibility of endodontic file tip and subjective assessment of image clarity.

  • PDF

The apical root canal shape according to the root canal system of premolars with single root (단근 소구치의 근관계 형태에 따른 치근단 부위의 근관 형태)

  • Park, Min-Soo;Hwang, Ho-Keel;Jo, Hyoung-Hoon
    • The Journal of the Korean dental association
    • /
    • v.55 no.1
    • /
    • pp.63-70
    • /
    • 2017
  • Materials and methods: Sixty extracted premolars were assigned to three groups according to the root canal system (Weine's classification; type I, II and III) of 20 teeth each using radiographic examination. The root tip was cut horizontally 1 mm from the anatomical apex and the apical cross-section was visualized using microscope at x50 magnification and photographed. Minimum and maximum apical root canal diameter of each tooth was measured and classified into three types by canal morphology (round, oval and flattened shape). Statistical analysis was performed to compare the apical root canal diameter and morphology according to the root canal system. Results: In apical root canal morphology at cross-sectional view, the most common shape was round in type I, flat in type II, and oval in type III. In apical root canal diameters at cross-sectional view, there was a significant difference between the minimum and maximum diameter in all types (p<0.05). The maximum diameter was 0.331 mm in type I, 0.519 mm in type II, and 0.310 mm in type III. There was a significant difference among type I, III and type II (p<0.05). Conclusion: The morphology and diameter of apical root canal was different according to the root canal system. Therefore, clinicians should consider the apical file size in view of the apical root canal shape according to the root canal system.

  • PDF

A Study on the Analysis Parameter Used in Improved EFG Crack Analysis Technique Based on Error Estimate (오차분석을 통한 개선된 EFG 균열해석기법의 해석계수 영향평가)

  • 이상호;윤영철
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.4
    • /
    • pp.703-713
    • /
    • 2002
  • Recently, an improved EFG(Element-Free Galerkin) crack analysis technique, which includes a discontinuous approximation and a singular basis function on the auxiliary supports, was developed. The technique is able to accurately analyze the crack propagation problem without any modification of the analysis model; however, it shows some dependency on the analysis parameters used. In this study, the effect of analysis parameters such as the size of compact support, dilation parameter, the smoothness of shape function around the crack tip, and the number of node using auxiliary supports on the accuracy of solution has been investigated. Through a patch test with a crack, relative L₂ error norm of stresses and the stress intensity factor were computed and compared for various analysis parameters and the results were presented as guidelines for adequate choice of analysis parameters.

Design of Asynchronous Library and Implementation of Interface for Heterogeneous System (비동기 라이브러리 설계와 Heterogeneous시스템을 위한 인테페이스 설계)

  • Jung, Hwi-Sung;Lee, Joon-Il;Lee, Moon-Key
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.9
    • /
    • pp.47-54
    • /
    • 2000
  • We designed asynchronous event logic library with 0.25um CMOS technology and interface chip for heterogeneous system with high-speed asynchronous FIFO operating at 1.6GHz. Optimized asynchronous standard cell layouts and Verilog models are designed for top-down design methodology. A Method for mitigating a design bottleneck when it comes to tolerate clock skew is described. This communication scheme using clock control circuits, which is used for the free of synchronization failures, is analyzed and implemented. With clock control circuit and FIFO, high-speed communication between synchronous modules operating at different clock frequencies or with asynchronous modules is performed. The core size of implemented high-speed 32bit-interface chip for heterogeneous system is about $1.1mm{\times}1.1mm$.

  • PDF

AN IMMUNOHISTOCHEMICAL STUDY ON THE CELLULAR CHANGE IN EPITHELIUM AND SUBEPITHELIAL TISSUE OF NON-INFLAMMATORY GINGIVAL HYPERPLASIA (비염증성 치은증식증의 상피 및 상피하조직내 세포변화에 관한 면역조직화학적 연구)

  • Choi, Yeoung-Wook;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.605-621
    • /
    • 1993
  • The gingival hyperplasia refers to an increase in the size of the gingival tissue produced by an increase in the number of its component cells. In order to investigate the cellular change in epithelium and subepithelial tissue of noninflammatory gingival hyperplasia, the gingival tissues were surgically obtained from the patients with dilantin gingival hyperplasia and idiopathic gingival hyperplasia. The excised tissue samples were fixed in neutral formalin for 6-24 hours, embedded with paraffin, sectioned at $4-6{\mu}m$ in thickness, mounted on glass slides coated with 3-aminopropyltriethoxysilane(Sigma Chemical Co., St. Louis, MO, U.S.A.) and immunocytochemically processed by Avidin-Biotin peroxidase complex method for detecting proliferating cell nuclear antigen, tenascin and collagen type IV. Monoclonal mouse anti-human PCNA antibody(Oncogene Science, Uniondale, NY, U.S.A., 1 : 250,000), monoclonal mouse anti-human tenascin antibody(Chemicon-International Inc., Temecula, CA, U.S.A., 1:5,000), and monoclonal mouse anti-human collagen type IV(Dakopatts, Glostrup, Denmark, 1: 50) were used as primary antibodies. The results were as follows: 1. In non-inflammatory gingival hyperplasia, the positive reaction to proliferating cell nuclear antigen was localized in the basal cell layer of gingival epithelium and well-developed rete pegs. 2. The positive reaction to tenascin was shown in the connective tissue subjacent to basament membrane of gingival tissue, and especially strong positive reaction was noted in the tip portion of connective tissue projections. 3. The positive reaction to collagen type IV was localized along the basement membranes of gingival epithelium and blood vessels. The results suggest that connective tissue enlargement may affect the proliferation of gingival epithelium.

  • PDF

Fabrication of Bump-type Probe Card Using Bulk Micromachining (벌크 마이크로머시닝을 이용한 Bump형 Probe Card의 제조)

  • 박창현;최원익;김용대;심준환;이종현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.661-669
    • /
    • 1999
  • A probe card is one of the most important pan of test systems as testing IC(integrated circuit) chips. This work was related to bump-type silicon vertical probe card which enabled simultaneous tests for multiple semiconductor chips. The probe consists of silicon cantilever with bump tip. In order to obtain optimum size of the cantilever, the dimensions were determined by FEM(finite element method) analysis. The probe was fabricated by RIE(reactive ion etching), isotropic etching, and bulk-micromachining using SDB(silicon direct bonding) wafer. The optimum height of the bump of the probe detemimed by FEM simulation was 30um. The optimum thickness, width, and length of the cantilever were 20 $\mum$, 100 $\mum$,and 400 $\mum$,respectively. Contact resistance of the fabricated probe card measured at contact resistance testing was less than $2\Omega$. It was also confirmed that its life time was more than 20,000 contacts because there was no change of contact resistance after 20,000 contacts.

  • PDF

Fatigue Crack Growth of Welded-Structural Steel under Simple-Variable Loading (단순변동하중(單純變動荷重)을 받는 용접구조용강(鎔接構造用鋼)의 피로균열성장(疲勞龜裂成長))

  • Chang, Dong Il;Bak, Yong Gul;Lee, Bong Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.4
    • /
    • pp.103-113
    • /
    • 1987
  • Fatigue tests using a single-peak loading and a two-step loading were carried out to examine the fatigue crack growth behaviar and to find the appropriate analysis method. C-T specimens were made using structural steel SWS58 for the tests. From this, just after a single-peak loading acceleration effect was occured and after some times retardation effect was found. And eminent retardation effect was found after High-Low two-step loading. The transition effect of crack growth due to this variable loading was occured owing to the residual stress and the plastic zone size at the crack tip. And the behaviors of these are well explained by Elber's Crack Closure Model. Also I could find that the Wheeler's Retardation Model is a simple and appropriate theory among analysis methods of fatigue crack growth under the variable loading.

  • PDF

Study of Flexible Forming Process Involving the Use of Sectional Flexible Die for Sheet Material (분할가변금형을 이용한 박판의 가변성형공정 연구)

  • Heo, Seong-Chan;Ku, Tae-Wan;Song, Woo-Jin;Kim, Jeong;Kang, Beom-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.299-305
    • /
    • 2010
  • In general, the flexible forming die that has been used in the flexible forming process has the identical punch size; hence, its flexibility is relatively low because the range of allowable curvature radii is limited due to the uniform punch tip radius. Hence, a conceptual design of a sectional flexible die is presented for enhancing the flexibility of the forming process. Two punches of different sizes are used to configure the arbitrary forming surface. For a forming region with a relatively large curvature radius, a large punch array block is used; on the other hand, for the forming regions with small curvature radii, a small punch block is used. The cross-sectional profiles are compared with the target shape for evaluating the effectiveness of the process. Consequently, it is confirmed that the sectional flexible die can be used along with a combination of punch blocks of different sizes for manufacturing objective surfaces of complex shapes.

Numerical Simulations of Crack Initiation and Propagation Using Cohesive Zone Elements (응집영역요소를 이용한 균열진전 모사)

  • Ha, Sang-Yul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.6
    • /
    • pp.519-525
    • /
    • 2009
  • In this study a cohesive zone model was used to simulate the delamination phenomena which occurs by a successive crack initiation and propagation in composite laminates. The cohesive zone model was incorporated to the classical finite element method via cohesive element formulation and then implemented into the user-subroutine UEL of a commercial finite element program Abaqus. To validate the formulation and implementation of the cohesive element the finite element results were compared with the experimental data of double cantilever beam and end notched flexure tests. The numerical results well agree with the experimental load-displacement curves. Also the effect of the elastic stiffness and the size of the cohesive element on the global load-displacement curves were studied numerically. To minimize the mesh-dependency of the crack propagation path and eliminate the zig-zag patterns in the load-displacement curve, cohesive elements should be refined at the crack-tip.

Effect of Water Content on the Morphology of ZnO Powders Synthesized in Binary Solvent Mixtures by Glycol Process

  • Phimmavong, Kongsy;Song, Jeong-Hwan;Cho, Seung-Beom;Lim, Dae-Young
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.3
    • /
    • pp.211-216
    • /
    • 2017
  • ZnO nanopowder was synthesized using a relatively facile and convenient glycol process. ZnO nanopowder was successfully synthesized at temperatures as low as $125^{\circ}C$ using zinc acetate as the Zn source and 1,4-butanediol as the solvent. Then, the effects of water content on the growth process and morphological evolution of ZnO powders were investigated using 1,4-butanediol and water as binary solvent mixtures. Using pure 1,4-butanediol at a temperature above $125^{\circ}C$, the prepared hexagonal ZnO nanopowder exhibited a quasi-spherical shape with average crystalline size of approximately 30 - 50 nm. It is also demonstrated that the morphology of ZnO powders can be controlled by the addition of various water content in 1,4-butanediol. With increasing water content, the morphologies of the ZnO powders changed sequentially from quasi-spherical to hexagonal plate and pyramid, and finally to hexagonal prismatic with a pyramidal tip. A sharp peak centered at 384 nm in the UV region and a weak broad peak in the visible region between 450 and 700 nm were shown in the room temperature PL spectra of the ZnO synthesized using the glycol process, regardless of the addition of water, suggesting that ZnO nanopowders with the best crystallinity were obtained under these conditions.