• Title/Summary/Keyword: Time-alignment

Search Result 715, Processing Time 0.031 seconds

Treatment of Distal Tibia Fracture using MIPPO Technique with Locking Compression Plate: Comparative Study of the Intraarticular Fracture and Extraarticular Fracture (잠김-압박 금속판을 사용하여 MIPPO 수기를 적용한 원위부 경골 골절의 치료: 관절내 골절과 관절외 골절의 비교)

  • Chung, Soo-Tae;Kim, Hyung-Soo;Cha, Seung-Do;Yoo, Jeong-Hyun;Park, Jai-Hyung;Kim, Joo-Hak;Jung, Jin-Ha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.162-168
    • /
    • 2009
  • Purpose: To evaluate the efficiency of the minimally invasive percutaneous plate osteosynthesis (MIPPO) with locking compression plate (LCP) for distal tibial metaphyseal intra-articular fracture compared with extra-articular fracture. Materials and Methods: From February 2006 to June 2008, 21 patients with distal tibia metaphyseal intra-articular fracture and 20 patients with extra-articular fracture were treated operatively by MIPPO technique with LCP and followed for at least one year. In the group with intra-articular fracture, mean age was 48.85 years old and a mean follow-up was 15 months. In the other group with extra-articular fracture, mean age was 52.35 years old and a mean follow-up was 14.5 months. The type of fracture was evaluated using the AO/OTA classification and open-fractures were according to the Gustilo-And gron classification. Radiologic evaluation with fracture healing and tibial alignment, clinical evaluation with Olerud and Molander ankle score and restriction of motion were done for treatment. Results: According to AO/OTA classification, There were 21 type A, 15 type B, 5 type C. Average union time of the intra-articular fracture (type B, C) was 18.7 weeks. Average union time of the extra-articular fracture (type A) was 17.1 weeks. All fractures were healed without malunion. There were no difference of mean restriction angle between intra-articular fracture (ankle dorsiflexion was 3.57 degree, plantar-flexion was 5.95 degree) and extra-articular fracture (ankle dorsiflexion was 3 degree, plantar-flexion was 3.75 degree). There were no difference of Olerud and Molander ankle score between them as a mean score of intra-articular and extra-articular was 89.25, 91.25 each other. As a complication, there were 3 case of skin necrosis, 8 case of discomfortable skin tenting by plate and 1 superficial infection, but could be healed by conservative care. Conclusion: MIPPO technique, combined articular reduction, with LCP of distal tibial metaphyseal fracture was a good method with high functional recovery.

  • PDF

Safe Driving Inducement Effect Analysis of Smart Delineator through Driving Simulation Evaluation (도로 주행 시뮬레이션 평가를 통한 스마트 델리네이터의 안전운전 유도 효과분석)

  • Ko, Han-Geom;Kim, Ji-Ho;Seong, Myung-Jae;Lee, Jin-Soo
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.4
    • /
    • pp.43-59
    • /
    • 2012
  • Assuming a completed Smart Highway road & communication environment that allows real-time information collection and transmission of road traffic condition ahead, the purpose of this study is to develop a plan for inducing a network-level safe driving pattern by providing road traffic condition and safety information to multiple drivers through a road information provision device. In this study, the device with a function that displays different colors according to the hazard level to the existing delineator has been named 'Smart Delineator'. Smart Delineator is a device that provides not only alignment information but also safety information for drivers to receive real-time warning information and intuitively recognize road traffic condition ahead so that drivers can respond. To examine the effects of safety driving inducement level on drivers, a simulation test was conducted using driving simulator as well as a satisfaction survey. The result showed that the Smart Delineator was able to identify the location of occurrence and affecting driving according pattern, either adhering to recommended speed or reducing speed according to the pre-defined hazard level.

ATTITUDE AND EXPOSURE CORRECTIONS OF FIMS DATA (원자외선분광기 FIMS 자료의 자세정보 및 노출시간 보정)

  • Seon, K.I.;Yuk, I.S.;Ryu, K.S.;Lee, D.H.;Park, J.H.;Jin, H.;Shinn, J.H.;Nam, U.W.;Han, W.;Min, K.;Korpela Eric;Nishikida Kaori;Edelstein Jerry
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.399-416
    • /
    • 2004
  • The FIMS (Far-ultraviolet IMaging Spectrograph), the main payload onboard the first Korean science satellite STSAT-1, has performed various observations since its launch on September 2003. It has been found that the attitude informations provided by spacecraft bus system have a time offset problem, and the problem has been extensively studied. After the time offset correction, boresight offsets between FIMS fields of view, of long and short wavelength bands, respectivley, and spacecraft attitude systems, which are mainly due to alignment error between the FIMS and spacecraft mechanical systems, were calculated through the observations of well known calibration targets. Monthly status and precision of the attitude information are also described. Correction methods for spatially variable exposure, intrinsic to FIMS data, are discussed. These results are essential to the FIMS data analysis, and will be used as references for subsequent studies on more accurate attitude corrections.

Study on Electro-optic Characteristics of the Optically Compensated Bend Liquid Crystal Display Using UV Curable Monomer (광경화성 단분자를 이용한 광학 보상 휨 액정 디스플레이의 전기광학 특성연구)

  • Lim, Young-Jin;Jeon, Eun-Jeong;Kwon, Dong-Won;Kim, Jeong-Hwan;Jeong, Kwang-Un;Lee, Myong-Hoon;Lee, Seung-Hee
    • Polymer(Korea)
    • /
    • v.33 no.5
    • /
    • pp.496-500
    • /
    • 2009
  • Optically compensated bend liquid crystal display (OCB-LCD) has many application fields owing to its fast response time and wide viewing angle. However, in order to operate the OCB-LCD in bend state, this device needs quick transitions from the initial splay state to bend state. Unlike conventional approach using transient high voltage for the transition, the OCB-LCD with high surface tilt angle, which was achieved by polymerization of UV curable reactive mesogen monomer under certain voltage, was manufactured and the cell showed bend state initially. Electro-optic and electrical characteristics of the cell were analyzed. The cell shows a fast response time owing to high surface pretilt angle and very low residual DC less than 0.1 V although another polymer layer is formed above polymer alignment layers.

Factors Influencing Crash Severity by the Types of Bus Transportation Services Using Ordered Probit Models (순서형 프로빗 모형을 이용한 버스 운송사업 유형 별 사고심각도 영향요인 분석)

  • YOON, Sangwon;KHO, Seung-Young;KIM, Dong-Kyu
    • Journal of Korean Society of Transportation
    • /
    • v.36 no.1
    • /
    • pp.13-22
    • /
    • 2018
  • Buses, one of the representative public transportation modes, are divided into a vareity of service types according to the purpose of operation, operating distance, and management agencies. Although bus-involved crashes may cause large amount of damage due to the higher number of passengers boarded on a bus, prior research has little focused on crash severity according to bus service types. This study aims to investigate factors influencing crash severity in bus-involved crashes and to present policy implications to reduce crash severity by bus service type. To do this, bus-involved crash data from the Traffic Accident Analysis System (TAAS) during five-year period are used. Ordered probit models for three types of bus service, i.e., city bus, suburban and express buses, and charter buses, are estimated to analyze the factors of accident severity. The results show that there are significant differences of factors affecting crash severity among the types of bus services while speed and road surface influence all the types of buses. In case of local buses, time of day, roadway alignment, and installation of a traffic signal are found to be statistically significant factors. Seat belt and road class have significant effects on injury severity of the intercity and express buses. Chartered buses have time of day, driving experience, seatbelt, traffic signal, and day of week as the significant factors. The results of this study are expected to contribute to the reduction of the crash severity by each bus service type.

Fabrication and analysis of $1.3\mum$ spot-size-converter integrated laser diodes (광모드변환기가 집적된 $1.3\mum$ SC-FP-LD 제작 및 특성 해석)

  • 심종인
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.271-278
    • /
    • 2000
  • We have fabricated and analyzed the lasing characteristics of 1.3$\mu\textrm{m}$ Spot-Size-Converter (SSC) integrated Fabry-Perot (FP) laser diodes, which are very promising light sources for optical subscriber networks. SSC-LDs has been developed by BIB (buttjoint-built-in) coupling and selective MOVPE growth. High-performances were achieved such as the slope efficiency from the SSC facet of 0.23-0.32 mW/mA, the full-width at the half maximum of the far-field pattern (FFP) of 9.5$^{\circ}$~12.3$^{\circ}$, the alignment tolerances of $\pm$2.3$\mu\textrm{m}$ and $\pm$2.5$\mu\textrm{m}$ within the extra-coupling loss of 1 dB for the vertical and parallel directions, respectively. These experimental results were compared to theoretical ones in order to clarify the operational problems and give a good design direction of the fabricated SSC-LDs. It was revealed that an asymmetric output power from the facets, an irrelevancy of FFP and the waveguide structure around SSC facet region, and a poor temperature characteristics were originated from the scattering in the BIB and SSC sections and SHB effect in the active section for the first time.t time.

  • PDF

Study on MPI-based parallel sequence similarity search in the LINUX cluster (클러스터 환경에서의 MPI 기반 병렬 서열 유사성 검색에 관한 연구)

  • Hong, Chang-Bum;Cha, Jeoung-Ho;Lee, Sung-Hoon;Shin, Seung-Woo;Park, Keun-Joon;Park, Keun-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.6 s.44
    • /
    • pp.69-78
    • /
    • 2006
  • In the field of the bioinformatics, it plays an important role in predicting functional information or structure information to search similar sequence in biological DB. Biolrgical sequences have been increased dramatically since Human Genome Project. At this point, because the searching speed for the similar sequence is highly regarded as the important factor for predicting function or structure, the SMP(Sysmmetric Multi-Processors) computer or cluster is being used in order to improve the performance of searching time. As the method to improve the searching time of BLAST(Basic Local Alighment Search Tool) being used for the similarity sequence search, We suggest the nBLAST algorithm performing on the cluster environment in this paper. As the nBLAST uses the MPI(Message Passing Interface), the parallel library without modifying the existing BLAST source code, to distribute the query to each node and make it performed in parallel, it is possible to easily make BLAST parallel without complicated procedures such as the configuration. In addition, with the experiment performing the nBLAST in the 28 nodes of LINUX cluster, the enhanced performance according to the increase in the number of the nodes has been confirmed.

  • PDF

Identification of Differentially Expressed Genes in Four Different Growing Stages in Korea Native Chicken Liver (황갈색 재래닭의 간에서 성장 단계별 차등 발현 유전자 분석)

  • Lee, K.Y.;Yu, S.L.;Jung, K.C.;Jang, B.K.;Choi, K.D.;Lee, J.H.
    • Korean Journal of Poultry Science
    • /
    • v.34 no.2
    • /
    • pp.85-90
    • /
    • 2007
  • The chicken liver has been involved in various biological functions including detoxification, glycogen storage and plasma protein synthesis. The aim of this study was to investigate differentially expressed genes in chicken liver in four different growing stages. Using 10 arbitrary Annealing Control Primers (ACPs), five differentially expressed genes have been identified. Based on the Basic Local Alignment Search Tool (BLAST) search results, three of them were matched with previously known genes, and the other two were matched with unknown EST sequence and a hypothetical protein, respectively. In order to confirm the expression results, quantitative real-time PCR was also performed. The high similarities between the expression data using arbitrary ACPs and quantitative real-time PCR indicate that the identified genes are the real differentially expressed genes in different growing stages. The genes identified in this study can be used as valuable biomarkers in chicken with further investigation of the functions.

Molecular Analysis of Pathogenic Molds Isolated from Clinical Specimen (임상검체에서 분리된 병원성 사상균의 분자생물학적 분석)

  • Lee, Jang Ho;Kwon, Kye Chul;Koo, Sun Hoe
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.229-236
    • /
    • 2020
  • Sixty-five molds isolated from clinical specimens were included in this study. All the isolates were molds that could be identified morphologically, strains that are difficult to identify because of morphological similarities, and strains that require species-level identification. PCR and direct sequencing were performed to target the internal transcribed spacer (ITS) region, the D1/D2 region, and the β-tubulin gene. Comparative sequence analysis using the GenBank database was performed using the basic local alignment search tool (BLAST) algorithm. The fungi identified morphologically to the genus level were 67%. Sequencing analysis was performed on 62 genera and species level of the 65 strains. Discrepancies were 14 (21.5%) of the 65 strains between the results of phenotypic and molecular identification. B. dermatitidis, T. marneffei, and G. argillacea were identified for the first time in Korea using the DNA sequencing method. Morphological identification is a very useful method in terms of the reporting time and costs in cases of frequently isolated and rapid growth, such as Aspergillus. When molecular methods are employed, the cost and clinical significance should be considered. On the other hand, the molecular identification of molds can provide fast and accurate results.

CLINICAL CONSIDERATION ON USING THE ELASTIC 'TIE BACKS' DURING SPACE CLOSURE ('Elastic tie back'을 이용한 발치공간 폐쇄에 관한 임상적 고려)

  • Cho, Ki-Soo;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.217-227
    • /
    • 1993
  • Preadjusted appliance, following the original concept of the Andrews Straight-Wire appliance, became increasingly common in the 1980s. In six phases of treatment, anchorage control, leveling and aligning, overbite control, overjet reduction, space closure, and finishing are very effective with using the preadjusted appliances. Space closure is the phase of treatment in which the difference between standard edgewise and preadjusted mechanics is most noticeable. Orthodontists have been able to reduce the use of closing loops and, because of the level slot lineup, enjoy the advantages of sliding mechanics. In 1990, Dr. John C. Bennett and Richard P. McLaughlin introduced the new space closure system, namely, elastic 'tiebacks'. They found an $.019'\times.025'$ working archwire most effective in an .022'-slot system. Hooks of .024' stainless steel or .028' brass wire are soldered to the upper and lower archwires. The force required for space closure is delivered by elastic 'tiebacks'. An elastic modulo stretched by 2-3mm(to twice its normal length) usually delivers 0.5-1.5mm of space closure per month. Group movement and sliding mechanics are combined for gentle, controlled space closure, so that about 0.5mm of incisor retraction and 0.5mm of mesial molar movement can be seen each month. The tiebacks are replaced every four to six weeks. By using the elastic 'tiebacks', the next two cases were treated during space closure. Even though we found some clinical problems of this mechanics, long treatment time, hard to control of vertical dimension and anchorage, the application method of this system is so simple that orthodontists can manage many patients during short chair time. But we must apply this mechanics after perfect understanding of the biomechanics in tooth movement.

  • PDF