• 제목/요약/키워드: Time difference voltage data

검색결과 38건 처리시간 0.034초

태양광 모듈 개별 모니터링을 위한 무선 IoT센서 (Development of Wireless IoT Sensors for Individual Photovoltaic Module Monitoring)

  • 박종성;김창헌;이지원;김지현;유상혁;양범승
    • Current Photovoltaic Research
    • /
    • 제9권3호
    • /
    • pp.106-109
    • /
    • 2021
  • In order to perform photovoltaic (PV) operation and management (O&M) efficiently, individual PV module monitoring is becoming more important. In this research, we developed wireless IoT sensor which can monitor individual photovoltaic modules. This IoT sensor can detect the output voltage, current and module temperature of individual modules and provide monitored data by wireless communication. Measured voltage error was 1.23%, and it shows 16.6 dBM, 0.42sec and 7.1 mA for voltage, transmittance output, response time and mean power consumption, respectively. IoT sensors were demonstrated in the test field with real climate environment condition and each of 5 sensors showed precise results of voltage, current and temperature. Also, sensors were compared with commercial power-optimizers and showed result difference within 5%.

고전압 가스 차단기용 전자석 조작기에 대한 해석 (Analysis of New Type of Switchgear for High Voltage Gas Circuit Breaker)

  • 이승민;강종호;김래은;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.872-873
    • /
    • 2008
  • In this paper, a new type of switchgear, electro magnetic force driving actuator (EMFA), is developed and analyzed, applicable to high voltage gas circuit breaker (HGCB). Transient analysis is performed in order to obtain the dynamic characteristics of the EMFA. The distribution of static magnetic flux is obtained using the finite element method (FEM). The governing electric and kinematical equations are solved using the time difference method (TDM). Fabrication and experiments were performed in order to prove the applicability of HGCB for overall class. In comparing the experiment with simulated data, it is confirmed that analysis of the dynamic characteristics of EMFA is appropriate for design.

  • PDF

유한요소법에 의한 초고압 OF 케이블 접속재의 주도해석에 관한 연구 (Study on the Thermal Analysis of Extra-High Voltage OF Cable Accessories using Finite Element Method)

  • 이종범;강동식;강도현;이수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.211-215
    • /
    • 1989
  • This paper presents the thermal analysis of EHV OF cable accessories using FEM. The governing equation about the temperature in the cable accessories is induced by the energy balance equation. Since the temperature distribution is a function of space and time, the weighted residual method is adopted for FEM formulation. The difference approximation is used to treat the time differential term in the element equation. Automatic mesh generation which save time and labor is introduced for the data input process. It will be expected that the following thermal analysis result will be very useful to cable accessories design.

  • PDF

로드셀을 이용한 직물의 신축성 측정에 관한 연구 (A Study on the Elasticity Measurement of Fabric Using Loadcell)

  • 주기세
    • 한국정보통신학회논문지
    • /
    • 제8권7호
    • /
    • pp.1532-1536
    • /
    • 2004
  • 지금까지는 직물의 신축성 측정은 작업자의 과거 경험을 바탕으로 작업자의 수작업에 의해 측정하였기 때문에 계량화된 신축성 데이터가 존재하지 않았다. 본 논문에서는 실시간으로 직물의 신축성 계수를 측정하기 위하여 특별히 제작된 로드 셀을 이용한 측정 장비가 소개된다. 측정방법은 직물에 따라 다르게 나타나는 로드 셀에 가해진 전압차를 기본으로 한다. 신축성이 강한 직물은 로드 셀에 강한 전압이 발생하며 신축성이 약할수록 약한 전압이 발생한다. 제안된 시스템은 직물의 시각화, 의류봉제, 품질관리 등에 이용될 뿐만 아니라 정량화된 데이터들은 B2B 전자상거래 시스템에 적용될 수 있다.

A Study on the Development of Arduino-Electrochemical Cell and the Exploration of Educational Possibilities from the Perspective of Learning by Making

  • Yoon, Jihyun;Cheon, Ji-Hye;Kang, Seong-Joo
    • 대한화학회지
    • /
    • 제65권3호
    • /
    • pp.219-229
    • /
    • 2021
  • In this study, the new electrochemical cell device using Arduino and sensor was developed, and experiments of changes in voltage at the time of serial and parallel connection of electrochemical cells were conducted to verify the effectiveness of the device. In addition, in order to examine the educational effects of the device, student's inquiry activities of measuring voltage of electrochemical cells and making objects using the voltage difference were conducted. As a result, it was confirmed that the electrochemical device using Arduino and sensor could not only perform automatic measurements and visualize data but also have a possibility to seek various educational effects through easy coding and modification of the device. Based on the results of students' performance, it was found that experimental activities using the device impart a positive effect not only on the understanding of scientific concepts, but also on the development of the practical ability to apply scientific knowledges to the real life. Educational implications are discussed in terms of 'learning by making'.

특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구 (A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System)

  • 정흥수;김민영;김준석
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.36-46
    • /
    • 2008
  • 본 논문은 대전력시험설비를 이용한 특고압 가스 절연 부하 개폐기의 대전력 시험회로의 구성과 통합형 시험 방법에 관하여 연구하였다. 대전력시험설비는 전기기기의 전기적 및 기계적인 성능을 검증하는 설비로서 단락발전기, 보호차단기, 투입스위치, 임피던스, 고압변압기, 저압변압기, 측정 및 보호시스템 등으로 구성되며, 이 시스템을 이용하여 단시간전류시험, 전류개폐용량시험, 단락투입 및 차단시험 등을 실시한다. 특고압 가스 절연 부하 개폐기의 규격으로는 국내 배전계통에 적용되는 ES(한국전력공사 표준규격) 5925-0002가 있으며, 국제 규격으로는 IEC 60265-1, 62271-1 및 IEEE C 37.74 등이 있다. 본 논문에서는 여러 규격에 각각 규정되어 있는 시험 절차, 시험회로 구성 및 시험 방법 등을 통합하여 600[MVA]급 대전력 시험설비에 적용하였다.

고압회전기 절연진단 및 수명평가 기술현황 (A technology State of Life Estimation and Insulation Diagnosis for High Voltage Rotating Machine)

  • 최영찬;왕종배;김기준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.31-35
    • /
    • 2000
  • We worried about the technology difference between our company and the advanced company at present motor market and are asked to set up the independent coil insulation system to accumulate insulation technology data. And to export our products at oversee market, we are asked to the evaluation of insulation performance to show our product excellence. In this study, we evaluated the insulation system of our motor, and studied the insulation diagnosis technology systematically to do site diagnosis. We are now accumulating the measured data. And also to reduce the initial insulation failure, we performed the insulation characteristic test and acquired the data to evaluate the initial soundness. We are doing the improvement of the insulation system. And also these data were used to new product development as very useful data, also will be used in the insulation deterioration diagnosis to estimate the remained life time which is very important data for the maintenance management. As the result, we were able to get our product reliability.

  • PDF

노후화된 누전차단기의 과전류 동작 특성에 관한 연구 (A Study on the Operating Characteristics of the Aged ELCB according to the Overcurrent)

  • 박예진;강신동;김재호
    • 한국안전학회지
    • /
    • 제38권5호
    • /
    • pp.1-7
    • /
    • 2023
  • This study analyzes the operational characteristics of 311 aged and non-aged residual current circuit breakers (RCCBs) in low-voltage consumer contexts. It investigates the influence of external temperature and harmonics based on the rated current multiples. To simulate temperature variations, a convectional oven was used around the circuit breakers. Additionally, the generation of harmonic reference signals and data measurement for overcurrent experiments were conducted using NI SCXI, myDAQ, and LabVIEW. An observation revealed that as the ambient temperature increased, the operating time of RCCBs decreased in the time delay region. This was attributed to the faster response or bending of the bimetal, which is the tripping element. However, aged RCCBs encountered challenges with tripping outside the protective curve. The operating time of the circuit breakers exhibited an acceleration influenced by the order and content of harmonic currents, potentially leading to malfunctions. Aged RCCBs demonstrated faster operating times than their non-aged counterparts. However, the difference in operating time varied based on the manufacturer's and operating environment of the RCCBs. Frequent malfunctions of RCCBs can result in power outages. In cases where these circuit breakers fail to operate, they can lead to secondary damages, including electrical fires and shocks. Consequently, it is imperative to consider the operating environment of RCCBs and provide appropriate replacement cycles to mitigate these risks.

DDR SDRAM을 위한 저전압 1.8V 광대역 50∼500MHz Delay Locked Loop의 설계 (Design of Low Voltage 1.8V, Wide Range 50∼500MHz Delay Locked Loop for DDR SDRAM)

  • 구인재;정강민
    • 정보처리학회논문지A
    • /
    • 제10A권3호
    • /
    • pp.247-254
    • /
    • 2003
  • 본 연구에서 고속 데이터 전송을 위해 Double Data Rate(DDR) 방식을 사용하는 SDRAM에 내장할 수 있는 저전압 광대역 Delay Locked Loop(DLL) 회로를 설계하였다. 고해상도와 빠른 Lock-on 시간을 위하여 새로운 유형의 위상검출기론 설계하였고 카운터 및 Indicator 등 내장회로의 빠른 동작을 위해 Dual-Data Dual-Clock 플립플롭(DCDD FF)에 기반을 둔 설계를 수행하였으며 이 FF을 사용하므로서 소자수를 70% 정도 감소시킬 수 있었다. Delay Line 중에서 Coarse 부분은 0.2ns 이하까지 검출 가능하며 위상오차를 더욱 감소시키고 빠른 Lock-on 기간을 얻기 위해 Fine 부분에 3-step Vernier Line을 설계하였다. 이 방식을 사용한 본 DLL의 위상오차는 매우 적고 25ps 정도이다. 본 DLL의 Locking 범위는 50∼500MHz로 넓으며 5 클럭 이내의 빠른 Locking을 얻을 수 있다. 0.25um CMOS 공정에서 1.8V 공급전압 사용시 소비전류는 500MHZ 주파수에서 32mA이다. 본 DLL은 고주파 통신 시스템의 동기화와 같은 다른 응용면에도 이용할 수 있다.

고압회전기 절연시스템 열화특성분석을 통한 성능평가 (Evaluation of Aging on Coil Insulation System for Rotating Machines)

  • 최영찬;김홍제;서동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.922-924
    • /
    • 2000
  • We worried about the technology difference between our company and the advanced companies at present motor market. Thus we started independently to develop the technology of motor coil insulation system and to accumulate insulation technology data. When we export the electric machines to oversee market. we are asked to set up the insulation system to show our product excellence. We first evaluate the insulation system of our motors to realize higher reliability of high voltage insulation system. Therefore we are possible to do the insulation diagnosis in real site and have accumulated the data related in insulation diagnosis. Thus we have improved the our insulation system. And also these data were used to new product development as very useful data. also will be used the insulation deterioration diagnosis to estimate the remained life time which is very important data for the maintenance management. As the result. we are able to get the our product reliability.

  • PDF