• Title/Summary/Keyword: Time Difference Method

Search Result 4,359, Processing Time 0.033 seconds

A Study on DOA and Delay Time Presumption based on Average Method (평균방법에 근거한 DOA와 지연시간추정에 관한 연구)

  • 이관형;송우영
    • Journal of the Korea Society for Simulation
    • /
    • v.13 no.2
    • /
    • pp.1-12
    • /
    • 2004
  • This paper estimated the arrival angle and electric wave delay time using the space method law and the directions of arrival (DOA) estimation algorithm in case of signal correlation. Space method law is the method used to repress cross correlation before applying the weight value to the receiving signal. The values of the diagonal elements in the correlation matrix were averaged to replace as the diagonal elements value. In the area of wireless communication or mobile communication, there are high correlations in case of low delay time difference in multiple waves. This causes the quality of the communication to drop due to interference with the desired signal elements. This paper estimated the arrival angle and electric wave delay time using the space method law and the MUSIC algorithm. With the arrival angle algorithm, the arrival angle cannot be estimated below 5 in case of signal correlations because the angle resolution capacity decreases accordingly. The super resolution capacity was estimated to determine the arrival angle below 5 in this paper. In addition, the proposed algorithm estimated the short delay time difference to be below 20ns.

  • PDF

Field Application of the Mass Concrete Utilizing Combined Method for Temperature Crack Reduction (온도균열 저감공법을 복합사용한 매스콘크리트의 현장적용)

  • Han, Sang-Yoon;Lee, Chung-Sub;Baek, Dae-Hyun;Jang, Duk-Bae;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.37-39
    • /
    • 2010
  • In this study, with new office construction site of S Construction company as subject, to solve all the problems according to reduced hydration heat and temperature crack of mass concrete used mat foundation and placing time difference, low heat combination of coarse particle cement and fly-ash and setting time difference applied AE water reducing agent, and to prevent the early frost damage caused by low outdoor temperature, a heat insulation method using double bubble sheet was conducted. As a result, it was found that hydration heat and setting time difference was reduced by applying a low heat combination and setting time difference construction method, and that the high insulation capability of the double bubble sheet was able to not only prevent the early frost damage but also reduce temperature difference between the central part and the upper part of mass concrete.

  • PDF

A Study about Direction Estimate Device of the Sound Source using Input Time Difference by Microphones′ Arrangement (마이크로폰 배열로 발생되는 입력 시간차를 이용한 음원의 방향 추정 장치에 관한 연구)

  • 윤준호;최기훈;유재명
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.91-98
    • /
    • 2004
  • Human uses level difference and time difference to get space information. Therefore this paper shows that method to presume direction of sound source by time difference and to mark presumed position. The position means direction from geometrical center of sensors to the sound source. To get the time difference of microphones input level, we will be explained about arrangement of microphones which used for the sensor to take the sound signal. It is included distance among the 3 microphones and distance between microphones and sound source. Secondly, input signals are transmitted to CPU througth digital process. CPU is used to DSP(Digital Signal Processor) for manage the signal by real time. Finally, the position of sound source is perceived by an explained algorithm in this paper.

A Method on the Control of Hydration Heat of Mass Concrete Considering the Difference of Setting Time (응결시간차를 활용한 매스콘크리트의 수화열 조정공법)

  • 심보길;윤치환;한민철;김기철;오선교;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.379-384
    • /
    • 2001
  • This Paper Presents field application test results of mass concrete using super retarding agent. The field test was carried out at mat foundation(thickness 1m) of newly constructed information center of Chongju university. Placing lift composed of 2 layers, and each layer is 50cm. Fly ash and flowing method is also applied. Difference of setting time of concrete between with super retarding agent and without super retarding agent is considered. Concrete without super retarding agent is placed at upper layer and with super retarding agent at lower layer According to test results, the reducing method of hydration heat considering difference of setting time with super retarding agent can reduce the highest temperature about 3~4$^{\circ}C$, and delay the peak time about 3~4days. Compressive strength using super retarding agent is somewhat higher than that of normal concrete. Accordingly, super retarding agent does not affect the strength development.

  • PDF

Multiple Model Prediction System Based on Optimal TS Fuzzy Model and Its Applications to Time Series Forecasting (최적 TS 퍼지 모델 기반 다중 모델 예측 시스템의 구현과 시계열 예측 응용)

  • Bang, Young-Keun;Lee, Chul-Heui
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.101-109
    • /
    • 2008
  • In general, non-stationary or chaos time series forecasting is very difficult since there exists a drift and/or nonlinearities in them. To overcome this situation, we suggest a new prediction method based on multiple model TS fuzzy predictors combined with preprocessing of time series data, where, instead of time series data, the differences of them are applied to predictors as input. In preprocessing procedure, the candidates of optimal difference interval are determined by using con-elation analysis and corresponding difference data are generated. And then, for each of them, TS fuzzy predictor is constructed by using k-means clustering algorithm and least squares method. Finally, the best predictor which minimizes the performance index is selected and it works on hereafter for prediction. Computer simulation is performed to show the effectiveness and usefulness of our method.

  • PDF

Analysis of Coaxial Line Transmission Charactristics and Shielding Effectiveness Using by Finite Difference Time Domain Method (시간영역 유한차분법을 이용한 동축선로의 전송특성 및 차폐효과 해석)

  • 남상식;윤현보;김정렬;백낙준;우종우
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.4
    • /
    • pp.11-19
    • /
    • 1995
  • In this paper, the Finite Difference Time Domain (FDTD) method is used to analyse the characteristics of the coaxial line transmission coefficent, shielding effectiveness, and compared to results of the moment method. The excitation mode of the Gaussian pulse is assumed to be a TEM-mode instead of the TE or TM-mode and in order to eliminate the reflected wave with in short length of the line. Calculated value of shielding effectiveness of the coaxial line by the FDTD are in good agreement with the results of the moment method.

  • PDF

Determination of BDOCrapid and BDOCslow using Batch Bio-reactor (회분식 생물반응기를 이용한 BDOCrapid와 BDOCslow 결정)

  • Son, Hee-Jong;Roh, Jae-Soon;Kang, Lim-Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.357-364
    • /
    • 2004
  • In this study, biodegradable organic matter was divided into a rapidly biodegradable fraction($BDOC_{rapid}$) and a slowly biodegradable fraction($BDOC_{slow}$) for various waters with different types of DOC. These fractions($BDOC_{rapid}$ and $BDOC_{slow}$) were defined by using a shaking incubation method modified from Carlson's method. Also, in this study, optimum incubation time and accuracy were investigated to determine $BDOC_{rapid}$ and $BDOC_{slow}$. When suspended bacteria obtained from raw water and BAC effluent, or attached bacteria from BAC was respectively used as an inoculum, the difference in total BDOC($BDOC_{total}$) was minimal. Therefore, total BDOC was determined in 7~8 days by the shaking method, which is comparable with Servais's method by which BDOC was determined in 28 days. In addition, the difference of BDOC between these two methods was within 7%. Although $BDOC_{rapid}$ and $BDOC_{slow}$ were effectively determined by a method defined by Klevens, the difference in optimal incubation time was significant for different water samples. However, when using the shaking method, optimal incubation time for $BDOC_{rapid}$ was found to be 3 days, therefore, the $BDOC_{rapid}$ was defined as the difference between $DOC_0$ and $DOC_{3days}$, and $BDOC_{slow}$ was defined as the difference between $BDOC_{total}$ and $BDOC_{rapid}$. As a conclusion, for determining the fraction of BDOC using the shaking method, the concentrations of an inoculurns and optimal incubation times used in this study were very effective.

Three-dimensional Finite Difference Modeling of Time-domain Electromagnetic Method Using Staggered Grid (엇갈린 격자를 이용한 3차원 유한차분 시간영역 전자탐사 모델링)

  • Jang, Hangilro;Nam, Myung Jin;Cho, Sung Oh;Kim, Hee Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.3
    • /
    • pp.121-128
    • /
    • 2017
  • Interpretation of time-domain electromagnetic (TEM) data has been made mostly based on one-dimensional (1-D) inversion scheme in Korea. A proper interpretation of TEM data should employ 3-D TEM forward and inverse modeling algorithms. This study developed a 3-D TEM modeling algorithm using a finite difference time-domain (FDTD) method with staggered grid. In numerically solving Maxwell equations, fictitious displacement current is included based on an explicit FDTD method using a central difference approximation scheme. The developed modeling algorithm simulated a small-coil source configuration to be verified against analytic solutions for homogeneous half-space models. Further, TEM responses for a 3-D anomaly are modeled and analyzed. We expect that it will contribute greatly to the precise interpretation of TEM data.

Efficient 3D Acoustic Wave Propagation Modeling using a Cell-based Finite Difference Method (셀 기반 유한 차분법을 이용한 효율적인 3차원 음향파 파동 전파 모델링)

  • Park, Byeonggyeong;Ha, Wansoo
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.2
    • /
    • pp.56-61
    • /
    • 2019
  • In this paper, we studied efficient modeling strategies when we simulate the 3D time-domain acoustic wave propagation using a cell-based finite difference method which can handle the variations of both P-wave velocity and density. The standard finite difference method assigns physical properties such as velocities of elastic waves and density to grid points; on the other hand, the cell-based finite difference method assigns physical properties to cells between grid points. The cell-based finite difference method uses average physical properties of adjacent cells to calculate the finite difference equation centered at a grid point. This feature increases the computational cost of the cell-based finite difference method compared to the standard finite different method. In this study, we used additional memory to mitigate the computational overburden and thus reduced the calculation time by more than 30 %. Furthermore, we were able to enhance the performance of the modeling on several media with limited density variations by using the cell-based and standard finite difference methods together.

AN EXPERIMENTAL STUDY FOR THE EFFECT OF SANDWICH TECHNIQUE ON MICROLEAKAGE IN CLASS V CAVITY (Sandwich 술식에 제V급 와동의 미세 변연누출에 미치는 영향에 대한 연구)

  • Shin, Chang-Seung;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.447-462
    • /
    • 1993
  • To evaluate the marginal leakage in Class V cavity this study has been undertaken to compare the sandwich technique with the conventional method, and find out the effect of lining material, lining method, and polishing time on sandwich technique. Ninty extracted teeth were divided into eight test groups and a control group, and were prepared with a buccal Class V cavity. Four test groups were lined with Dentin Cement whereas the other four test groups were lined with Vitrabond. Half of the either group were lined 0.5mm short of the carvosurface margin and the rest were lined completely to the carvosurface margin. The four subgroups were further divided into specimens which were polished immediately and 24 hours after resin filling. The polished specimens were immersed in $37^{\circ}C$, 0.5% methylene blue solution for 24 hous after thermocycling at $5^{\circ}C$ and $55^{\circ}C$, 200 times and buccolingually sectioned. The sectioned specimens were examined dye penetration under the light microscope. The following results were obtained, 1. At the enamel margin, the conventional method showed a lower microleakage than the sandwich technique. The difference between the control and Vitrabond group was statistically significant(P<0.05), but no difference between the control and Dentin Cement group, and between the lining materials was observed. 2. At the dentinal margin, the sandwich technique showed a significant lower amount of microleakage (P<0.05), but there was no significant difference between the lining materials. 3. Regardless of the lining material, lining method, and polishing time used, values of microleakage were significantly higher at the dentinal margin compared to the enamel margin(P<0.05). 4. In specimens till the cavosurface margin, microleakage at the dentinal margin was less with the light-cured base than with the chemically-cured base, but there was no siginificantly difference between the lining materials regarding the lining method and polishing time. 5. The lining material, lining method, and polishing time did not affect the amount of micro leakage in the sandwich technique(P<0.05).

  • PDF