• Title/Summary/Keyword: Tightness

Search Result 438, Processing Time 0.024 seconds

Sick Building Syndrome in 130 Underground Workers (지하상가 근무자의 건강 장애에 관한 실태조사)

  • Joo, Ree;SaKong, Joon;Chung, Jong-Hak;Park, Sang-Whan;Kim, Dong-Hee;Kim, Dong-Min;Choi, Eun-Kyong;Cho, Hyun-Geon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.325-340
    • /
    • 1998
  • A cross-sectional study was conducted to evaluate the relationship between sick building syndrome(SBS) and the environmental factors affecting SBS on 130 underground workers and 60 controls. The study consisted of 1) a review of environmental condition 2) measurement of temperature, $O_2$, $CO_2$, CO, and formaldehyde and 3) a questionnaire survey of symptom prevalence and perception of environmental conditions using indoor Air Quality questionnaire recommended by National Institute for Occupational Safety and Health. Bronchitis and dust allergy were more prevalent in underground workers significantly(p < 0.05). Among the 18 symptoms related to the indoor air pollution, the experience rate of dry, itching or irritated eyes, sore or dry throat, chest tightness, tired or strained eyes and dry or itchy skin symptom was significantly different between the underground workers and controls. The diagnostic criteria of SBS was defined as at least 1 symptom is experienced 1-3 times a week during the last 1 month among 18 indoor air pollution related symptoms which can be relieved by moving out of the underground. Applying the criteria, the mean symptom score was significant higher in underground workers than controls significantly (p < 0.05). These resalts indicated that underground workers are under inappropriate ergonomic and physical condition and inadequate ventilation. Their experience rate of symptoms related to indoor air pollution and prevalence of SBS was significantly higher than controls. To reduce the prevalence of SBS of underground workers, the surveillance system of indoor air quality, restriction of using fuel in underground and legislative regulations for the environment are needed to establish a better indoor air quality. Early detection, treatment and prevention of SBS through medical attention is also needed.

  • PDF

Formaldehyde Exposure in the Plywood Manufacturing Factory (목재 가공업소에서의 Formaldehyde폭로)

  • Ha, Myung-Wha;Kim, Doo-Hie;Lim, Hyun-Sul;Park, Sang-Hu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.1 s.33
    • /
    • pp.37-44
    • /
    • 1991
  • In the plywood manufacturing factory established in 1979, female 3 workers who had exposed to adhesives containing formaldehyde for more than 48 months of duration suffered from eye, nasal, oral, throat and skin irritation and dyspnea as chief complaints. The actual level of the exposure to formaldehyde were not estimated when the exposed workers started to have above symptoms. The environmental monitoring of workplace was measured on April 25, 1990, and the concentration of formaldehyde revealed 0.2 ppm, however the exhaustive ventilatory system was already installed at that time. Twenty six subjects from entire factory were examined by questionnaire, physical examination and spirometry, etc. on August 22, 1990. Significant difference was observed in symptoms and signs of nasal, oral and throat irritation between the exposed group with longer duration and that with short duration. When the exposed group with longer duration was compared to the group of nonexposed, symptoms and signs of nasal, oral, throat and skin irritaion, chest tightness and dullness were significantly increased in the former group. The results of the spirometric test showed that the forced vital capacity and the forced expiratory volume at 1 second were decreased among the exposed group with longer duration but not significant.

  • PDF

The Clothing Behavior, School Uniform Satisfactions and School Uniform Modification Behavior of Adolescent (청소년의 의복행동과 교복만족도 및 교복변형행동)

  • Lee Yae-Kung;Han Young-Sook;Lee Hye-Ja
    • Journal of Korean Home Economics Education Association
    • /
    • v.18 no.3 s.41
    • /
    • pp.133-148
    • /
    • 2006
  • The purpose of this study was to acquire the better and more correct information on the school uniforms with which middle or high school students may be satisfied. We investigated clothing interest, school uniform satisfaction, school uniform modification behavior and the relationship anions those factors. The data were collected from 472 questionnaires of middle and high school students who lived in Gyeonggi-do and analyzed statistically. We found that adolescents felt a great interest in appearance, fashion, brand orientation of clothing, and they spent most of personal expenses in buying clothes. However, the extent of adolescents' satisfaction on school uniform was low. Especially, the satisfaction on status symbolism, fashion, washing & management, body comfort and economical efficiency of school uniform was found low. Three hundred fifty three students (74.8%) agreed to modify the school uniform for personality and in chase of fashion. Two hundred eighty four students (58.1%) needed partially and variously modified school uniform, and these modifications showed a tendency of tightness to the body. We also found that the higher adolescents' clothing interests in appearance, conformity, modesty and brand orientation were. the more satisfied adolescents were with the status symbolism and the washing & management of school uniform and the more affected the school uniform modification behaviors of students were. There were. however. no significant difference between the extent of school uniform satisfaction and the school uniform modification behavior, Another research of school uniform will be necessary in order to reduce the discrepancy between clothing needs for representing the appearance, personality and fashion in the present adolescents and those for representing the worthy and modest images of a student and pursuing the economic value through school uniform in the older generation. We suggest that students should consider these results when they choose school uniform and furthermore both the person in charge of schools and school uniform makers should refer to those when they design and make school uniform.

  • PDF

Giant Coronary Artery Aneurysm Presenting as a Calcified Mediastinal Mass a, Coronary Artery Fistula - A case report - (종격동 종양으로 오인된 거대관상동맥류와 관상동맥루 - 치험 1례 -)

  • Yoon, You-Sang;Lee, Cheol-Joo;Choi, Ho;Kang, Jun-Kyu;Choi, Jin-Wook;Kim, Hyung-Tae
    • Journal of Chest Surgery
    • /
    • v.34 no.10
    • /
    • pp.787-791
    • /
    • 2001
  • Coronary artery aneurysm is a rare disorder. It is defined as abnormal dilatation of coronary artery with diameter exceeding 1.5 times the adjacent normal segments. The incidence of coronary aneurysm is 2.6% in Caucasians and 0.25% in Asians. Over half of the former were associated with atherosclerotic coronary artery disease. However, 70 percents of the latter were nonobstructive coronary artery aneurysms. Coronary artery fistula is a rare disorder. It has been identified in only 0.2% of routine cardiac angiographic studies conducted over a 10-year period. The clinical spectrums are various, asymtomatic, asymptomatic murmur, dyspnea on exertion, fatigue, and congestive heart failure. The right coronary artery (56%) and left coronary artery(36%) are mainly involved in the origin site of congenital coronary artery fistula. The draining site of fistula are right ventricle(39%), right atrium(33%), and pulmonary artery(20%) and so on. This 54 years-old woman had intermittent chest tightness and an abnormal mediastinal shadow on chest roentgenogram and chest C-T examination, which was diagnosed as a mediastinal mass such as teratoma. We performed the operation under left anterolateral thoracotomy for mass excision. However, we knew the mass had the pulsating arterial blood flow through a fine needle puncture of the mass and that it was attached to the left ventricle. We believed the excision of mass on beating heart would be very dangerous. Therefore, we closed the wound without excising the mass. After several days, we performed an echocardiography and coronary angiography, We knew it was cardiac tumor. Incidentally, the patient had a tortuous coronary fistula from the right coronary artery to pulmonary trunk. Using cardiopulmonary bypass with moderate systemic hypothermia, the mass was resected and the fistula was clipped with surgical clips. Pathology of the specimen was a giant coronary arterial aneurysm.

  • PDF

Type Classification and Material Properties by the Composition of Components in Gold Earrings Excavated from the Yeongnam Region (영남지역 출토 금제 귀걸이의 성분 조성에 따른 유형 분류와 금속 재료 특성)

  • Jeon, Ikhwan;Kang, Jungmoo;Lee, Jaesung
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.1
    • /
    • pp.4-21
    • /
    • 2019
  • In this paper, 23 Silla gold earrings from the sixth and seventhand centuries, excavated from the Yeongnam region, were analyzed. Based on the silver content of the gold plate, they were classified into three types. The classifications included type I(20-50wt%), type II(10-20wt%) and type III (less than 10wt%). In the analysis process, the composition and morphological differences were identified on the surface of the gold plate. In the case of type I and II earrings, it was observed that the fine holes were concentrated in a relatively higher part of the gold content. The causes of the difference in the surface composition of the gold plate were divided into four categories: 1) surface treatment, 2) thermal diffusivity in the manufacturing process, 3) differences in composition of alluvial gold, and 4) the refining method of gold. It is possible that depletion gilding was attempted to increase the gold content while intentionally removing the other metals from the surface of the gold alloy in the portion where the gold deposit is relatively concentrated on the surface of the gold plating. The highest copper content was detected in the earring with the highest gold content of the analyzed earrings, and it was assumed that thermal diffusion had occurred between the gold plate and the metal rod during the manufacturing process rather than intentional addition. Copper was detected only in the thin ring earring type, and copper was not detected in the thick ring earring type or pendant type. It also proves that this earring has a high degree of tightness at higher temperatures, as there was an invisible edge finish on other earrings and horizontal wrinkles on the gold plate surface. In terms of the material of the gold plate, we examined whether the silver content of the gold plate was natural gold or added by alloy through analyzing the alluvial gold collected in the region. As a result of the analysis, it was found that on average about 13wt% of silver is included. This suggests that type II is natural gold, type III is refined gold, and type I seems to have been alloyed with natural gold. Here, we investigated the refining method introduced in the ancient literature, both at home and abroad, about the possibility of alloying silver after the refining process of type III earrings and then making pure gold. It was found that from ancient refining methods, silver which had been present in the natural gold was removed by reacting and combining with silver chloride or silver sulfide, and long-term efforts and techniques were required to obtain pure gold through this method. Therefore, it was concluded that the possibility of adding a small amount of silver in order to increase strength after making pure gold through a refining process is low.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.

Study for Treatment Effects and Prognostic Factors of Bronchial Asthma -Follow Up Over 2 Years- (2년 이상 관찰중인 성안 기관지 천식환자의 치료 효과 및 예후인자에 관한 연구)

  • Choung, Bo-Young;Park, Jung-Won;Kim, Sung-Kyu;Hong, Chein-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.559-573
    • /
    • 1997
  • Background : Asthma causes recurrent episodes of wheezing, breathlessness, chest tightness, and cough. These symptoms are usually associated with widespread but variable airflow limitation that is partly reversible either spontaneously or with treatment. The inflammation also causes an associated increase in airway responsiveness to a variety of stimuli. Method : Of the 403 adult bronchial asthma patients enrolled from March 1992 to March 1994 in Allergy Clinics of Severance Hospital in Yonsei University, this study reviewed the 97 cases to evaluate the treatment effects and to analyse prognostic factors. The patients were classified to five groups according to treatment responses ; group 1 (non control group) : patients who were not controlled during following up, group 2 (high step treatment group) : patients who were controlled longer than 3 months by step 3 or 4 treatment of "Global initiative for asthma, Global strategy for asthma management and prevention" (NHLBI/WHO) with PFR(%) larger than 80%, group 3 (short term control group) : patients who were controlled less than 1 year by step 1 or 2 treatment of NHLBI/WHO, group 4 (intermediate term control group) : patients who were controlled for more than 1 year but less than 2 years by step 1 or 2 treatment of NHLBI/WHO, group 5 (long term control group) : patients who were controlled for more than 2 years by step 1 or 2 treatment of NHLBI/WHO. Especially the patients who were controlled more than 1 year with negatively converted methacholine test and no eosinophil in sputum were classified to methacholine negative conversion group. We reviewed patients' history, atopy score, total IgE, specific IgE, methacholine PC20 and peripheral blood eosinophil count, pulmonary function test, steroid doses and aggrevation numbers after treatment. Results : On analysis of 98 patients, 20 cases(20.6%) were classified to group 1, 26 cases(26.8%) to group 2, 23 cases(23.7%) to group 3, 15 cases(15.5%) to group 4, and 13 cases(13.4%) to groups 5. There were no differences of sex, asthma type, family history, smoking history, allergic rhinitis and aspirin allergy among the groups. In long term control group, asthma onset age was younger, symptom duration was shorter, and initial pulmonary function was better. The long term control group required lower amounts of oral steroid. had less aggrevation during first 3months after starting treatment and shorter duration from enrollment to control Atopy, allergic skin test, sputum and blood eosinophil, total IgE, nonspecific bronchial responsiveness was not significantly different among the groups. Seven out of 28 patients who were controlled more than 1 years showed negatively converted methachloine test and no eosinophils in the sputum. The mean control duration was $20.3{\pm}9.7$ months and relapse did not occur. Conclusion : Patients who had asthma of onset age younger, shorter symptom duration, better PFT, lower treatment initial steps, lower amounts of steroid needs and less aggravation numbers after starting treatment were classified in the long term control groups compared to the others.

  • PDF

Analysis of Heating Effect of an Infrared Heating System in a Small Venlo-type Glasshouse (소형 벤로형 유리온실에서 적외선등 난방 시스템의 난방효과 분석)

  • Lim, Mi Young;Ko, Chung Ho;Lee, Sang Bok;Kim, Hyo Kyeong;Bae, Yong Han;Kim, Young Bok;Yoon, Yong Cheol;Jeong, Byoung Ryong
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.3
    • /
    • pp.186-192
    • /
    • 2010
  • An infrared heating system, installed in a small venlo-type glasshouse ($280m^2$) in Gyeongsang National University, Jinju, Korea, was used to investigate its heating effect with potted Phalaenopsis, Schefflera arboricola 'Hongkong', Ficus elastica 'Variegata', and Rosa hybrida 'Yellow King' as the test plants. Temperature changes in test plants with the system turned 'On' and 'Off' were measured by using an infrared camera and the consumption of electricity by this infrared heating system was measured and analyzed. In potted Phalaenopsis, when the set air temperature of the greenhouse was $18^{\circ}C$, temperature of leaves and the growing medium were $22.8{\sim}27^{\circ}C$ and $21.3{\sim}24.3^{\circ}C$, respectively. In such tall plants as Schefflera arboricola 'Hongkong' and Ficus elastica 'Variegata', the upper part showed the highest temperature of 24.0 and $26.9^{\circ}C$, respectively. From the results of temperature change measurements, the plant temperatures were near or above the set point temperatures with some fluctuations depending on the position or distance from the infrared heating system. When air temperature between night and dawn dropped sharply, plant temperatures were maintained close to the set temperature ($18^{\circ}C$). There was a significant difference between 'On' and 'Off' states of the infrared heating system in average temperatures of root zone and leaf: 21.8 and $17.8^{\circ}C$ with the system 'On' and 20.4 and $15.5^{\circ}C$ with the system 'Off', respectively, in a cut rose Rosa hybrida 'Yellow King'. The heating load was about $24,850{\sim}35,830kcal{\cdot}h^{-1}$, which comes to about 27,000~40,000 won in Korean currency when calculated in terms of the cost of heating by a hot water heating system heated by petroleum. The cost for heating by the infrared heating system was about 35% of that of a hot water heating system. With the infrared heating system, the air temperature during the night was maintained slightly lower than the set point air temperature, probably due to the lack of air tightness of the glasshouse. Therefore, glasshouses with an infrared heating system requires further investigation including the installation space of the heat-emitting units, temperature sensor positions, and convection.