Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants  

Shin, Woo Jin (Department of Environmental science, Kangwon National University)
Lee, Chul Won (Department of Environmental science, Kangwon National University)
Kim, Man Goo (Department of Environmental science, Kangwon National University)
Publication Information
Analytical Science and Technology / v.20, no.4, 2007 , pp. 261-267 More about this Journal
Abstract
The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.
Keywords
20 L test chamber; building material; TVOC;
Citations & Related Records
연도 인용수 순위
  • Reference
1 환경부, '실내공간 실내공기오염 특성 및 관리방법연구', 2002
2 최상웅, 강원대학교 이화학석사학위논문, '건축자재의 휘발성유기화합물 방출시험에 이용되는 소형시험 챔버법들의 평가', 강원대학교 이화학석사학위논문, 2006
3 ISO 16000-9, Determination of the emssion of volatile organic compounds from building products and furnishing- Emission chamber method, 2006
4 ISO 16000-6, Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS/FID, 1994
5 김현진, 강원대학교 이화학석사학위논문, '건축자재의 휘발성 유기화합물과 알데하이드 방출시험을 위한 1 리터 시험챔버 개발', 강원대학교 이화학석사 학위논문, 2005
6 Zeli Que, Takeshi Faruno, Sadanobu katoh and Yoshihiko Nishino, Building and Environment, 1-8, Evaluation of three test methods in determination of formaldehyde emission from particleboard bonded with different mole ratio in the urea-formaldehyde resion, 2005
7 ECA, Guidline for the characterization of volatile organic compounds emitted from indoor materials and products using small emission test chambers. Report No. 8, EUR 13593 EN. Luxembourg: Official Publications of the European Communities, 1991
8 JIS A 1901, シックハウス對策に役立つ 小形チャンバ法, 2003